Rapid and Reliable Detection of Dissolved Gases in Water
Aplikace | 2014 | Thermo Fisher ScientificInstrumentace
GC, HeadSpace
ZaměřeníŽivotní prostředí
VýrobceThermo Fisher Scientific
Klíčová slovappb, fracturing, gases, hydraulic, water, ethane, propane, methane, ethylene, gas, dissolved, saturation, headspace, ppm, instant, reliable, wellbore, build, apparatuses, calibration, environmental, thermo, monitoring, conclusively, bubbling, caruso, massimo, equilibration, santoro, scientific, connect, liberated, controversial, traceplot, custody, standards, andrea, modularity, via, minutes, suitable, sand, method, reservoirs, rapid, curve, conservation, leaving, contaminate, exclusive
Podobná PDF
Automated, Rapid and Reliable Determination of Dissolved Gases in Water by Static Headspace – Gas Chromatography
2014|Thermo Fisher Scientific|Postery
Automated, Rapid and Reliable Determination of Dissolved Gases in Water by Static Headspace – Gas Chromatography A. Caruso, M. Santoro, F. Bedini, P. Magni, S. Pelagatti Thermo Fisher Scientific, Milan, Italy Overview Standards Preparation Purpose: Exploring the possibility to perform…
Klíčová slova
water, waterstatic, staticpropane, propanefracking, frackinggas, gasheadspace, headspaceethylene, ethyleneppb, ppbgases, gasesincreasing, increasingsaturated, saturatedvial, vialbuilding, buildingarea, areasampling
Alternative Methods to RSK 175 Using Purge and Trap Concentration and Automated Headspace for the Analysis of Dissolved Gases in Drinking Water
2013|Teledyne LABS|Aplikace
Alternative Methods to RSK 175 Using Purge and Trap Concentration and Automated Headspace for the Analysis of Dissolved Gases in Drinking Water Application Note Abstract With the growing price of oil, many alternative energy sources are being explored. Natural gas…
Klíčová slova
temp, temppurge, purgebake, baketime, timedesorb, desorbversa, versapressurize, pressurizeequil, equilcondenser, condenserrinse, rinseethene, etheneflow, flowplaten, platencalibration, calibrationvariable
Alternative Methods to RSK 175 Using Purge and Trap Concentration and Automated Headspace for the Analysis of Dissolved Gases in Drinking Water
2012|Teledyne LABS|Aplikace
Alternative Methods to RSK 175 Using Purge and Trap Concentration and Automated Headspace for the Analysis of Dissolved Gases in Drinking Water Application Note By: Nathan Valentine Abstract With the growing price of oil, many alternative energy sources are being…
Klíčová slova
temp, temppurge, purgebake, baketime, timedesorb, desorbversa, versapressurize, pressurizeequil, equilcondenser, condenserrinse, rinseethene, etheneflow, flowplaten, platencalibration, calibrationvariable
Methane, Ethylene, and Ethane in Water by Headspace-Gas Chromatography (HS-GC) with Flame Ionization Detection (FID)
2012|PerkinElmer|Aplikace
a p p l i c at i o n N o t e Gas Chromatography Authors Lee Marotta Dennis Yates PerkinElmer, Inc. Shelton, CT USA Methane, Ethylene, and Ethane in Water by Headspace-Gas Chromatography (HS-GC) with Flame Ionization Detection…
Klíčová slova
methane, methaneethane, ethaneaquifers, aquifersdev, devethylene, ethyleneconfirm, confirmheadspace, headspaceperkinelmer, perkinelmerfid, fidarea, areagas, gasyates, yatesaquifer, aquiferlease, leasepresents