Latest Advances in the Analysis of Volatile Organic Compounds by Single Quadrupole GC-MS
Aplikace | 2010 | Thermo Fisher ScientificInstrumentace
GC/MSD, Purge and Trap, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceThermo Fisher Scientific, OI Analytical
Klíčová slovabutylbenzene, methacrylate, methyl, tert, xylene, vinylchloride, chloroacetonitrile, chloride, quadrupole, diethylether, rsd, carbon, methacrylonitrile, propionitrile, pentachloroethane, fluorobenzene, isopropyltoluene, acrylate, tetrachloroethylene, dev, hexachloroethane, acrylonitrile, avg, allyl, nitrobenzene, isq, dibromomethane, bromobenzene, dichlorodifluoromethane, trichloroethylene, purge, trichlorofluoromethane, africa, chloroethane, bromochloromethane, isopropylbenzene, bromomethane, chloromethane, propylbenzene, dibromochloromethane, trap, bromodichloromethane, single, volatile, bromoform, hexachlorobutadiene, tetrahydrofuran, std, chlorobenzene, disulfide
Podobná PDF
Maximizing Speed and Separations for Lowering Drinking Water Detection Limits with GC/MS
2011|Thermo Fisher Scientific|Aplikace
Application Note: 52185 Maximizing Speed and Separations for Lowering Drinking Water Detection Limits with GC/MS Jessie Butler, Terry Jeffers, David Steiniger, Eric Phillips, Pat O’Brien, Thermo Fisher Scientific, Austin, TX, USA Overview Key Words • ISQ Single Quadrupole GC-MS •…
Klíčová slova
pass, passisq, isqpurge, purgebutylbenzene, butylbenzenedesorb, desorbnotification, notificationsegments, segmentsdev, devdichlorodifluoromethane, dichlorodifluoromethaneavg, avgtrichlorofluoromethane, trichlorofluoromethanebromomethane, bromomethaneafrica, africamdls, mdlsscientific
Reducing the helium consumption for analysis of VOCs in accordance with EPA Method 8260D without compromising performance using HeSaver-H2 Safer technology
2023|Thermo Fisher Scientific|Aplikace
Application note | 002337 Environmental Reducing the helium consumption for analysis of VOCs in accordance with EPA Method 8260D without compromising performance using HeSaver-H2Safer technology Goal Authors Amy Nutter , Terry Jeffers , Adam Ladak , To describe the use…
Klíčová slova
min, mintert, tertacetate, acetatequan, quanether, etheristd, istdbutyl, butylbutylbenzene, butylbenzenebake, bakepurge, purgeprecision, precisionmethyl, methylsweep, sweeptime, timeethyl
US EPA Method 524.2: Successful Measurement of Purgeable Organic Compounds in Drinking Water by Agilent 8860/5977B GC/MSD
2019|Agilent Technologies|Aplikace
Application Note Environmental US EPA Method 524.2: Successful Measurement of Purgeable Organic Compounds in Drinking Water by Agilent 8860/5977B GC/MSD Authors Bruce D. Quimby and Anastasia A. Andrianova Agilent Technologies, Inc. Abstract An Agilent 8860/5977B GC/MSD system coupled with a…
Klíčová slova
rrf, rrfistd, istdtrichloromonofluoromethane, trichloromonofluoromethanetribromomethane, tribromomethanebfb, bfbchloride, chlorideethyl, ethylmethyl, methylbutylbenzene, butylbenzenemethacrylate, methacrylatetetrachloroethylene, tetrachloroethyleneaquatek, aquateksurr, surrtert, tertmethylacrylonitrile
Routine analysis of volatile organic compounds in drinking water with ISQ 7000 GC-MS
2019|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE 65632 Routine analysis of volatile organic compounds in drinking water with ISQ 7000 GC-MS Authors: Adam Ladak1, David Lee2, and Amy Nutter3 1 Thermo Fisher Scientific, Groton, MA, USA 2 Thermo Fisher Scientific, Runcorn, UK 3 Teledyne Tekmar,…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinseprecision, precisionmethanol, methanolwater, watersurr, surrdesorb, desorbsweep, sweeproutine, routinechloride, chlorideether, etherbutylbenzene, butylbenzenemethacrylate