Lower Detection Limits of Volatile Nitrosamines in Tobacco by Triple Quadrupole GC-MS/MS
Aplikace | 2011 | Thermo Fisher ScientificInstrumentace
GC/MSD, GC/MS/MS, GC/QQQ
ZaměřeníPotraviny a zemědělství
VýrobceThermo Fisher Scientific
Klíčová slovaxls, quantum, vnas, tsq, vna, nitrosamines, scientific, tobacco, pci, thermo, timed, africa, volatile, method, srm, quadrupole, smokeless, uncontaminated, nmor, nmea, triple, npyr, preferable, npip, reaction, energy, autosampler, russia, detection, positive, chromatography, selected, limits, use, monitoring, using, east, lower, ionization, ndma, while, achievable, chemical, spectrometer, triplus, traditionally, spain, zealand, latin, austria
Podobná PDF
Rapid quantification of 12 nitrosamines in metformin using triple quadrupole GC-MS/MS with Advanced Electron Ionization (AEI)
2021|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE 000173 Rapid quantification of 12 nitrosamines in metformin using triple quadrupole GC-MS/MS with Advanced Electron Ionization (AEI) Authors: David Lee1, Aaron Lamb1, Andrea Romano2, and Giulia Riccardino2 Thermo Fisher Scientific, Runcorn, UK 2 Thermo Fisher Scientific, Milan, Italy…
Klíčová slova
nitroso, nitrosophenylamine, phenylaminenpyr, npyrnepha, nephanmpa, nmpandma, ndmahigh, highndpa, ndpanpip, npipndpha, ndphanmea, nmeandea, ndeandba, ndbandipa, ndipanmor
A validated method for the rapid determination of fifteen nitrosamines in metformin drug substance
2021|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE 10753 A validated method for the rapid determination of fifteen nitrosamines in metformin drug substance Authors: Dujuan Lu¹, Danny Hower1, Aaron Lamb2, Andrea Romano3, Dominic Roberts2 and Cristian Cojocariu2; 1 SGS, Fairfield NJ, USA, 2 Thermo Fisher Scientific,…
Klíčová slova
fda, fdapositive, positivenipea, nipeametformin, metforminndbea, ndbeaneba, nebanmpa, nmpanepha, nephandma, ndmandpha, ndphandea, ndeanpip, npipndba, ndbandipa, ndipanmor
Unparalleled performance of Advanced Electron Ionization GC-MS/MS technology for the determination of nitrosamines in drinking water 
2018|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE 10615 Unparalleled performance of Advanced Electron Ionization GC-MS/MS technology for the determination of nitrosamines in drinking water Authors Aaron Lamb,1 Cristian Cojocariu,1 Sara Insa,2 and Maria José Farré2 Thermo Fisher Scientific, Runcorn, UK 1 Catalan Institute for Water…
Klíčová slova
nitrosamines, nitrosaminespass, passndea, ndeandma, ndmandba, ndbanmea, nmeanpyr, npyrnpip, npipndpa, ndpawater, watercounts, countsratio, ratiominutes, minutesdrinking, drinkingaei
High Sensitivity Analysis of Nitrosamines Using GC-MS/MS
2012|Thermo Fisher Scientific|Aplikace
Alex Chen1, Hans-Joachim Huebschmann2, Li Fangyan3, Chew Yai Foong3 and Chan Sheot Harn3 Alpha Analytical Pte. Ltd., Singapore; 2Thermo Fisher Scientific, Singapore, 3Health Sciences Authority, HSA Singapore 1 Keywords: Nitrosamines, Food Safety, beer, TSQ 8000, GC-MS/MS, quantitation, confirmation, AutoSRM, TraceFinder…
Klíčová slova
nitrosamines, nitrosaminesetofenprox, etofenproxnitrosamine, nitrosaminenpyr, npyrnpip, npipfenamirol, fenamirolindoxacarb, indoxacarbndba, ndbanmor, nmorfisher, fisherfluquinconazol, fluquinconazolazinphosmethyl, azinphosmethylndma, ndmandea, ndeasilafluofen