Qualitative Calibration Mix - ASTM 3710

Aplikace |  | QuadrexInstrumentace
GC, GC kolony, Spotřební materiál
Zaměření
Průmysl a chemie
Výrobce
Quadrex
Klíčová slova
PDF verze ke stažení a čtení
 

Podobná PDF

Toggle
Simulated Distillation of Petroleum Products by Packed Column and Capillary Column GC
Bulletin 864A Simulated Distillation of Petroleum Products by Packed Column and Capillary Column GC Simulated distillation by gas chromatography (SIMDIS or GCD) is a technique often employed in the petrochemical industry for quickly determining the boiling range distribution of petrochemical…
Klíčová slova
petrocol, petrocolsimdis, simdispacked, packedboiling, boilingsupelco, supelcoastm, astmcolumn, columncolumns, columnsxylene, xylenebleed, bleedoctane, octanetoluene, toluenecapillary, capillarybutylbenzene, butylbenzeneheptane
Petroleum/Chemicals Application Guide
595 North Harrison Road Bellefonte, PA 16823-0048 USA Telephone 800-247-6628 ● 814-359-3441 Fax 800-447-3044 ● 814-359-3044 email: [email protected] sigma-aldrich.com/supelco Bulletin 858D Petroleum/Chemicals Application Guide This guide contains up-to-date information about Supelco products and technology for separating hydrocarbons by chromatographic methods.…
Klíčová slova
xylene, xylenehayesep, hayesepsupelco, supelcoscotty, scottymin, minfid, fidpetrocol, petrocolmix, mixmixes, mixestert, tertbenzene, benzenetoluene, toluenegasoline, gasolinebutane, butanehydrocarbons
Aromatics in Light Naphtha and Aviation Gasolines - ASTM 2267
GC CAPILLARY COLUMN APPLICATIONS: Petrochemical Aromatics in Light Naphtha and Aviation Gasolines ASTM 2267 COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: 007-23, Cyanopropyl Methylpolysiloxane 60M. x 0.25mm I.D. x 0.25μm film 007-23-60-0.25F 60° (3.0 min. hold) (10°/min.) - 260°C…
Klíčová slova
aviation, aviationnaphtha, naphthapetrochemical, petrochemicalaromatics, aromaticslight
ASTM D5441 - Impurities in MTBE
GC CAPILLARY COLUMN APPLICATIONS: Petrochemical ASTM D5441 Impurities in MTBE COLUMN: Cat. No.: Temperature: Flow: Injector: Detector: 007-1, Dimethylpolysiloxane PHAT Phase™ 20M. x 0.18mm I.D. x 6.0μm film 007-1-20HS-6.0F 40°(3 min. hold) (5°/min.) - 100° (12°/min) - 210°C 12 psi,…
Klíčová slova
petrochemical, petrochemicalmtbe