Robust and user-friendly backflush technology reduces GC maintenance and maximizes laboratory throughput
Technické články | 2021 | Thermo Fisher ScientificInstrumentace
GC
ZaměřeníVýrobceThermo Fisher Scientific
Klíčová slovabackflush, disabled, ptv, enabled, microfluidic, column, configuration, matrix, time, boiling, analytical, backflushes, laboratories, post, area, bkf, uptime, through, from, compounds, retention, setup, peak, iconnect, during, triallate, pre, backflushed, chlorantraniliprole, throughput, completely, inlet, testing, heavier, thermo, timing, device, deviation, pneumatic, module, scientific, rsd, stages, cyclohexane, instant, contamination, selfadjusted, high, thanks, entering
Podobná PDF
Eliminate Invisible High Boiling Matrix in GC and GC/MS by Using PTV Backflush Injection Technique for Increased Productivity and Reliability
2010|Thermo Fisher Scientific|Technické články
Technical Note: 51888 Eliminate Invisible High Boiling Matrix in GC and GC/MS by Using PTV Backflush Injection Technique for Increased Productivity and Reliability Fausto Munari, Thermo Fisher Scientific, Milano, Italy Hans-Joachim Huebschmann, Thermo Fisher Scientific, Austin, TX, USA Introduction Key…
Klíčová slova
bkf, bkfptv, ptvbackflush, backflushcolumn, columnhigh, highmatrix, matrixboiling, boilingpears, pearsextract, extractinjection, injectionboilers, boilersinjector, injectorpre, precomponents, componentsliner
Low-level consistent analysis of PBDEs in environmental and food matrices using triple quadrupole GC-MS/MS
2021|Thermo Fisher Scientific|Aplikace
Application note | 000493 Environmental Low-level consistent analysis of PBDEs in environmental and food matrices using triple quadrupole GC-MS/MS Authors Goal Kjell Hope , Giulia Riccardino , The aim of this application note is to demonstrate the performance of the…
Klíčová slova
pbdes, pbdesntr, ntrcalculated, calculatedation, ationpbde, pbdecon, conmin, minloq, loqinjection, injectiontracegold, tracegoldidl, idlensured, ensuredmea, meaiconnect, iconnectoret
High Precision Pesticide Analysis in Produce using GC Triple Quadrupole and U-SRM Mode
2012|Thermo Fisher Scientific|Aplikace
Application Note: 52279 High Precision Pesticide Analysis in Produce using GC Triple Quadrupole and U-SRM Mode Inge de Dobbeleer, Joachim Gummersbach, Hans-Joachim Huebschmann, Anton Mayer,Thermo Fisher Scientific, Dreieich, Germany Key Words • 1 ppb Levels • Challenging Compounds • Pesticide…
Klíčová slova
srm, srmptv, ptvxls, xlspesticides, pesticidestsq, tsqhyperquad, hyperquadultra, ultraquantum, quantumbackflush, backflushpesticide, pesticidefolpet, folpetquechers, quechersiprodion, iprodionazinphosmethyl, azinphosmethyltransitions
TRACE 1600 Series Gas Chromatograph AI/AS 1610 Liquid Autosampler
2021|Thermo Fisher Scientific|Brožury a specifikace
Gas Chromatography Stay ahead with measurably more production TRACE 1600 Series Gas Chromatograph AI/AS 1610 Liquid Autosampler Maximize uptime with a GC always ready to run If your gas chromatograph is only running part time, you’re missing the benefits of…
Klíčová slova
touchscreen, touchscreeniconnect, iconnectthermo, thermoscientific, scientificgas, gaschromatograph, chromatographmaintenance, maintenancechromeleon, chromeleoncontrol, controlcds, cdssmart, smarteasy, easyinjectors, injectorsautosamplers, autosamplersinjection