Capillary Split/Splitless Injector for the Clarus 590/690 GC | LabRulez GCMS
 

Podobná PDF

Toggle
Technical Guide1Operating Hints forUsing Split/SplitlessInjectorsInside:Overviews of split and splitlessinjection tech­niquesBackpressure-regulated injectionsystemsHeadpressure-regulated injectionsystemsOperating in the split injection modeInlet liners for split injectionsOperating in the splitless injectionModeInlet liners for splitless injectionsSeptum purge optimizationProblems associated with split andsplitless injectionsDirect injection as an alternative...
Klíčová slova
siltek, siltekliners, linersuniliner, unilinersplit, splitdeactivation, deactivationliner, linerinjection, injectionsplitless, splitlesssplitter, splitterfeaturing, featuringport, portwool, woolgcs, gcsinlet, inletpress
Technical GuideA Guide to Direct andOn-column FlashVaporization InjectionInside:Overviews of direct and on-columnflash vaporization injection techniquesAdvantages of direct injection oversplitless injectionPractical guidelines to maximizeanalysis accuracy and reproducibilityRecommendations for converting asplit/splitless injection port for directinjectionsAlternatives for converting a packedcolumn injection port for...
Klíčová slova
uniliner, unilinerdirect, directinjection, injectionliner, linersilcosteel, silcosteelweldment, weldmentgraphite, graphitesplitless, splitlessferrules, ferrulesliners, linersferrule, ferrulecolumn, columninlet, inletdescription, descriptioninstalls
Making a Grand Entrance:Techniques for EfficientSample Introduction, InletTypes, and MaintenanceMark Sinnott – Application EngineerAlexander Ucci - Application EngineerMarch 19, 20191March 29, 2019Techniques for Efficient Sample IntroductionAgilent Restricted Sample Injection Goals•Introduce sample into the column•Reproducible•Minimize efficiency losses•Representative of sample2March 29, 2019Techniques for...
Klíčová slova
restricted, restrictedefficient, efficienttechniques, techniquesagilent, agilentsplitless, splitlesssplit, splitsample, sampleintroduction, introductioninlet, inletvent, ventliner, linerdiscrimination, discriminationcolumn, columnsolvent, solventseptum
Endrin/DDT Stability for Fritted and Wool Liners
2020|Agilent Technologies|Aplikace
Application NoteEnvironmentalEndrin/DDT Stability for Fritted andWool LinersAuthorsLukas Wieder andAngela Smith Henry, PhDAgilent Technologies, Inc.AbstractThis application note demonstrates the lifetime of Agilent Ultra Inert fritted liners forenvironmental applications with complex, nonvolatile matrix in comparison to woolpacked liners. Endrin and 4,4′-DDT breakdowns...
Klíčová slova
wool, woolfrit, fritmid, midliner, linerendrin, endrinlow, lowagilent, agilentbreakdown, breakdownddt, ddtliners, linersmixture, mixturefritted, frittedlifetime, lifetimeinert, inertddd
 

Podobná PDF

Toggle
Technical Guide1Operating Hints forUsing Split/SplitlessInjectorsInside:Overviews of split and splitlessinjection tech­niquesBackpressure-regulated injectionsystemsHeadpressure-regulated injectionsystemsOperating in the split injection modeInlet liners for split injectionsOperating in the splitless injectionModeInlet liners for splitless injectionsSeptum purge optimizationProblems associated with split andsplitless injectionsDirect injection as an alternative...
Klíčová slova
siltek, siltekliners, linersuniliner, unilinersplit, splitdeactivation, deactivationliner, linerinjection, injectionsplitless, splitlesssplitter, splitterfeaturing, featuringport, portwool, woolgcs, gcsinlet, inletpress
Technical GuideA Guide to Direct andOn-column FlashVaporization InjectionInside:Overviews of direct and on-columnflash vaporization injection techniquesAdvantages of direct injection oversplitless injectionPractical guidelines to maximizeanalysis accuracy and reproducibilityRecommendations for converting asplit/splitless injection port for directinjectionsAlternatives for converting a packedcolumn injection port for...
Klíčová slova
uniliner, unilinerdirect, directinjection, injectionliner, linersilcosteel, silcosteelweldment, weldmentgraphite, graphitesplitless, splitlessferrules, ferrulesliners, linersferrule, ferrulecolumn, columninlet, inletdescription, descriptioninstalls
Making a Grand Entrance:Techniques for EfficientSample Introduction, InletTypes, and MaintenanceMark Sinnott – Application EngineerAlexander Ucci - Application EngineerMarch 19, 20191March 29, 2019Techniques for Efficient Sample IntroductionAgilent Restricted Sample Injection Goals•Introduce sample into the column•Reproducible•Minimize efficiency losses•Representative of sample2March 29, 2019Techniques for...
Klíčová slova
restricted, restrictedefficient, efficienttechniques, techniquesagilent, agilentsplitless, splitlesssplit, splitsample, sampleintroduction, introductioninlet, inletvent, ventliner, linerdiscrimination, discriminationcolumn, columnsolvent, solventseptum
Endrin/DDT Stability for Fritted and Wool Liners
2020|Agilent Technologies|Aplikace
Application NoteEnvironmentalEndrin/DDT Stability for Fritted andWool LinersAuthorsLukas Wieder andAngela Smith Henry, PhDAgilent Technologies, Inc.AbstractThis application note demonstrates the lifetime of Agilent Ultra Inert fritted liners forenvironmental applications with complex, nonvolatile matrix in comparison to woolpacked liners. Endrin and 4,4′-DDT breakdowns...
Klíčová slova
wool, woolfrit, fritmid, midliner, linerendrin, endrinlow, lowagilent, agilentbreakdown, breakdownddt, ddtliners, linersmixture, mixturefritted, frittedlifetime, lifetimeinert, inertddd
 

Mohlo by Vás zajímat

Utilising unique TOF-MS technology and hydrogen carrier gas for fast GC-MS to produce robust, high quality, library comparable mass spectral data

Postery
| 2022 | LECO
Instrumentace
GC/MSD, GC/TOF
Výrobce
LECO
Zaměření
---

Determination of BTEX and volatile organic compounds (VOCs) in drinking water by GC-MS/MS coupled to static headspace and solid-phase microextraction sampling

Aplikace
| 2022 | Thermo Fischer Scientific
Instrumentace
GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ
Výrobce
Thermo Fischer Scientific
Zaměření
Životní prostředí

Analysis of Trace Perfluorinated and Polyfluorinated Organic Vapors in Air

Aplikace
| 2022 | Agilent Technologies
Instrumentace
GC/MSD, Termální desorpce, GC/SQ
Výrobce
Agilent Technologies, Markes
Zaměření
Životní prostředí

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GC/MS System

Aplikace
| 2022 | Shimadzu
Instrumentace
GC/MSD, HeadSpace, GC/SQ
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

Analysis of Heavy Fuel Oil Using Multi-Mode Ionization

Aplikace
| 2022 | LECO
Instrumentace
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Výrobce
LECO
Zaměření
Průmysl a chemie
 

Mohlo by Vás zajímat

Utilising unique TOF-MS technology and hydrogen carrier gas for fast GC-MS to produce robust, high quality, library comparable mass spectral data

Postery
| 2022 | LECO
Instrumentace
GC/MSD, GC/TOF
Výrobce
LECO
Zaměření
---

Determination of BTEX and volatile organic compounds (VOCs) in drinking water by GC-MS/MS coupled to static headspace and solid-phase microextraction sampling

Aplikace
| 2022 | Thermo Fischer Scientific
Instrumentace
GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ
Výrobce
Thermo Fischer Scientific
Zaměření
Životní prostředí

Analysis of Trace Perfluorinated and Polyfluorinated Organic Vapors in Air

Aplikace
| 2022 | Agilent Technologies
Instrumentace
GC/MSD, Termální desorpce, GC/SQ
Výrobce
Agilent Technologies, Markes
Zaměření
Životní prostředí

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GC/MS System

Aplikace
| 2022 | Shimadzu
Instrumentace
GC/MSD, HeadSpace, GC/SQ
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

Analysis of Heavy Fuel Oil Using Multi-Mode Ionization

Aplikace
| 2022 | LECO
Instrumentace
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Výrobce
LECO
Zaměření
Průmysl a chemie
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití

LabRulez s.r.o. Všechna práva vyhrazena.