GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

Analysis of 1,4-Dioxane Using the Stratum PTC and the SOLATek 72

Aplikace | 2009 | Teledyne LABSInstrumentace
GC/MSD, Purge and Trap, GC/SQ
Zaměření
Životní prostředí
Výrobce
Agilent Technologies, Teledyne LABS
Klíčová slova
PDF verze ke stažení a čtení
 

Podobná PDF

Toggle
Optimization Techniques for Performance of USEPA Methods 5030, 5035, and Determinative Methods 524.2 and 8260 utilizing the Atomx Concentrator/Multimatrix Autosampler and an Agilent 7890A GC and 5975 inert XL MSD
Optimization Techniques for Performance of USEPA Methods 5030, 5035, and Determinative Methods 524.2 and 8260 utilizing the Atomx Concentrator/Multimatrix Autosampler and an Agilent 7890A GC and 5975 inert XL MSD Application Note By: Anne Jurek Abstract Environmental Analysts are frequently…
Klíčová slova
temp, tempbake, bakepurge, purgedesorb, desorbrinse, rinsevrx, vrxlens, lenssweep, sweeptime, timeapp, appflow, flowneedle, needledry, drycondenser, condenserstandby
Evaluating USEPA Method 524.3 Utilizing Newly Permissible Method Modifications to Purge and Trap Techniques
Evaluating USEPA Method 524.3 Utilizing Newly Permissible Method Modifications to Purge and Trap Techniques Application Note By: Anne Jurek Abstract Purge and Trap (P&T) concentration in conjunction with Gas Chromatography/Mass Spectrometry (GC/MS) is a widely used technique for the determination…
Klíčová slova
pass, passpurge, purgetemp, tempbake, bakeapp, appppb, ppbpir, pirmodifications, modificationsdesorb, desorbchloride, chloridebutylbenzene, butylbenzenecondenser, condenserfail, failtime, timecompound
Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70
Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70 Application Note Abstract Geosmin and 2-Methylisoborneol are organic compounds that have a distinct scent. These compounds also have an extremely low odor detection threshold and because of this,…
Klíčová slova
temp, tempbake, bakepurge, purgedesorb, desorbppt, pptcondenser, condensertime, timedrain, draingeosmin, geosminflow, flowspike, spikepreheat, preheatdry, drycryofocusing, cryofocusingcurve
Validation of USEPA Method 524.2 Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS
Validation of USEPA Method 524.2 Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS Application Note By: Nathan Valentine Abstract The US EPA developed Method 524.2¹, “Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas…
Klíčová slova
temp, temppurge, purgebake, bakedesorb, desorbcondenser, condensertime, timerinse, rinsebutylbenzene, butylbenzenedry, drypreheat, preheatflow, flowchloride, chloridemethacrylate, methacrylatedrain, drainacryl
Další projekty
LCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.