Organohalide Pesticides in Water by GC/μECD with Agilent J&W DB-CLP1 and DB-CLP2
Aplikace | 2012 | Agilent TechnologiesInstrumentace
GC, GC kolony, Spotřební materiál
ZaměřeníŽivotní prostředí
VýrobceAgilent Technologies
Klíčová slovanonachlor, chlordane, heptachlor, organohalide, pesticides, trans, bhc, epoxide, dieldrin, aldrin, endrin, hexachlorocyclopentadiene, water, pesticide, cis, hexachlorobenzene, tap, primary, dilution, prepared, pds, detect, epa, reagent, able, alachlor, simazine, methoxychlor, hexachllorocyclopentadiene, atrazine, extracted, min, sample, standard, manner, sub, fortify, hexane, commercially, commercial, level, baker, runoff, samples, established, doris, below, application, sulfite, appropriate
Podobná PDF
Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns
2012|Agilent Technologies|Aplikace
Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns Application Note Environmental Authors Abstract Doris Smith and Ken Lynam The Agilent J&W DB-CLP1 and DB-CLP2 column pair has the selectivity to separate Agilent Technologies,…
Klíčová slova
bhc, bhcmin, minester, estersurrogate, surrogateendrin, endrinmethyl, methylendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlordecachlorobiphenyl, decachlorobiphenyltetrachloro, tetrachloropermethrin, permethrinpeak, peakepoxide, epoxideclp
New Application Specific Columns
2013|Agilent Technologies|Prezentace
New Application Specific Columns Simon Jones GC columns Application Engineer What Columns are New? DB-CLP1 DB-CLP2 Environmental DB-UI 8270D DB-Select 624 UI 467 US Pharmacopeia What are the Benefits? Address specific issues with certain methods Response Tailing factor Resolution Named…
Klíčová slova
min, minbhc, bhcendrin, endrinheptachlor, heptachlorchlordane, chlordaneendosulfan, endosulfanpermethrin, permethrinpesticides, pesticidesepoxide, epoxidemethyl, methylaldrin, aldrinnonachlor, nonachlorbenzo, benzodecachlorobiphenyl, decachlorobiphenyltrans
New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories
2012|Agilent Technologies|Prezentace
New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories Ken Lynam CSD Application Chemist Presentation Outline • DB-UI 8270D columns for semi-volatile analysis – Testing procedures – Example chromatograms – Addition…
Klíčová slova
bhc, bhcmethyl, methylester, esterendrin, endrintranslation, translationheptachlor, heptachlorendosulfan, endosulfanchlordane, chlordaneenhancing, enhancingpackaging, packagingclp, clpliner, linerproductivity, productivitysurrogate, surrogateepoxide
Sub μg/L Level Analysis of Chlorinated Pesticide and Herbicide Analysis in Water by GC/μECD using Agilent J&W DB-35ms Ultra Inert and DB-XLB columns
2012|Agilent Technologies|Aplikace
Sub µg/L Level Analysis of Chlorinated Pesticide and Herbicide Analysis in Water by GC/µECD using Agilent J&W DB-35ms Ultra Inert and DB-XLB columns Application Note Environmental Authors Abstract Doris Smith and Ken Lynam Chlorinated pesticides and herbicides in water samples…
Klíčová slova
bhc, bhcendosulfan, endosulfanpermethrin, permethrinchlordane, chlordaneheptachlor, heptachlorendrin, endrinsurrogate, surrogatexlb, xlbdisk, disketradiazole, etradiazoletcmx, tcmxpesticides, pesticideschlorinated, chlorinateddcpa, dcpabutachlor