Optimizing GC-MS Analysis of 3-MCPD and Glycidyl Esters
Postery | 2020 | RestekInstrumentace
GC/MSD
ZaměřeníPotraviny a zemědělství
VýrobceRestek
Klíčová slovapba, split, splitless, ais, optimization, boronic, diethyl, mcpds, ether, modeler, method, had, curves, glycidyl, nabr, evaluation, effect, transesterification, catalyzed, ezgc, comparison, injection, acidified, naoh, inlets, nacl, fames, extraction, mtbe, regular, ptv, both, iso, phenyl, ester, calibration, simplify, led, concentration, dissolved, layer, changing, derivatization, stop, hexane, removed, temperatures, min, switching, pro
Podobná PDF
Faster GC-MS Analysis of 3-MCPD and Glycidyl Esters in Edible Oils
2019|Agilent Technologies|Aplikace
Featured Application: 3-MCPD and Glycidyl Esters on Rxi-17Sil MS Faster GC-MS Analysis of 3-MCPD and Glycidyl Esters in Edible Oils • Meet AOCS Cd 29c-13 method requirements with optimized GC conditions. • Use split injection to decrease analysis time by…
Klíčová slova
midpolarity, midpolaritycrossbond, crossbondsimilar, similarmin, mingcs, gcsinlets, inletsphases, phaseslength, lengthequipped, equippedsplitless, splitlesssplit, splittime, timepart, partpeaks, peaksagilent
A Fully Automated Method For MCPD – and GE- Esters And The Importance of Glass Quality Of the used Autosampler Vials
2019|Thermo Fisher Scientific|Postery
A Fully Automated Method For MCPD – and GE- Esters And The Importance of Glass Quality Of the used Autosampler Vials Petra Gerhards1, Detlev Lennartz1, Inge de Dobbeleer2, Martijn Vandenhoven2 1Thermo Fisher Scientific, Dreieich, Germany, 2SampleQ, Breda, The Netherlands ABSTRACT…
Klíčová slova
mcpde, mcpdemcpd, mcpdautomated, automatedtransesterification, transesterificationesters, estersreviewing, reviewingautomation, automationweighing, weighingglass, glassanalist, analistquality, qualityvial, vialput, putsampleq, sampleqtime
Determination of 2-MCPD and 3-MCPD Fatty Acid Esters in Infant Formula Using an Agilent 8890 GC System with an Agilent 5977B GC/MSD
2021|Agilent Technologies|Aplikace
Application Note Food Testing and Agriculture Determination of 2-MCPD and 3-MCPD Fatty Acid Esters in Infant Formula Using an Agilent 8890 GC System with an Agilent 5977B GC/MSD Authors Youjuan Zhang, Xia Yang, and Shuai Wang Agilent Technologies (Shanghai) Co.…
Klíčová slova
hfbi, hfbiocor, ocorpba, pbamcpdes, mcpdesmcpd, mcpdmcpds, mcpdsderivatization, derivatizationtransesterification, transesterificationcounts, countsglycidol, glycidolchloropropanediols, chloropropanediolsacid, acidwere, wereacquisition, acquisitionesterified
Determination of MCPD and glycidyl esters in foodstuff
2017|Bruker|Aplikace
GC/MS Application Note Determination of 2- and 3-MCPD and glycidyl esters in foodstuff www.palsystem.com Determination of MCPD and glycidyl esters in foodstuff Tobias Uber, Marco Nestola Axel Semrau GmbH, 45549 Sprockhövel, Germany Keywords: 3-Monochloropropane-1,2-diol, 3-MCPD, 2-Monochloropropane-1,3-diol, 2-MCPD, glycidol, fat, oil,…
Klíčová slova
dgf, dgfmcpd, mcpdclean, cleanglycidyl, glycidylfast, fastanalytics, analyticsctc, ctcoil, oilmanual, manualesters, estersglycidol, glycidolclassical, classicalquantifier, quantifierqualifier, qualifierdhr