TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans SwitchAplikace | 2019 | Restek InstrumentaceGC, GCxGC, GC/MSD, Termální desorpce, GC/SQ, GC kolony, Spotřební materiálZaměřeníŽivotní prostředíVýrobceAgilent Technologies, Markes, RestekKlíčová slovavinyl, chloride, tert, scan, mapd, butyl, alcohol, min, acetate, cyclopentane, fid, methylcyclopentane, isoprene, preconcentrator, isopentane, acrolein, isobutane, bfb, alumina, acetylene, peaks, bromide, allyl, amu, dichlorodifluoromethane, trichlorofluoromethane, extractor, bromochloromethane, chloroethane, butane, bromomethane, ethane, cyclohexane, propane, chloromethane, pentane, propylene, tetrahydrofuran, isopropyl, disulfide, scans, bond, methylene, ethylene, chloroform, ether, acetone, ethanol, hexane, notes
Podobná PDF
Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air
2016|Agilent Technologies|Aplikace
Rapid Determination of TO-15Volatile Organic Compounds (VOCs) in AirBy Jason S. HerringtonAbstractThe following study evaluated the efficacy of using Nutech’s 8900DS preconcentrator in combination with an analytical systembased on a 30 m x 0.32 mm x 1.00 µm Rxi®-5Sil MS...
Klíčová slova
bdl, bdltimeout, timeoutpptv, pptvppbv, ppbvaudit, audittime, timevinyl, vinylchloride, chloridemdl, mdlreplicate, replicateaverage, averageflow, flowprecision, precisiondesorb, desorbpurge
Optimize Analysis of Polar and Coeluting VOCs in Whole Air Canister Samples Using an Rtx®-VMS GC Column
2016|Agilent Technologies|Aplikace
Optimize Analysis of Polar and Coeluting VOCsin Whole Air Canister Samples Usingan Rtx®-VMS GC ColumnBy Jason S. Herrington, Ph.D.Laboratories that analyze volatile organic compounds (VOCs) in whole air canister samples often follow U.S. EnvironmentalProtection Agency (EPA) Compendium Method TO-15 [1]....
Klíčová slova
vms, vmsscan, scanmarkes, markespreconcentrator, preconcentratormin, minvocs, vocscanister, canisterbfb, bfbrtx, rtxamu, amuacknowledgement, acknowledgementcia, ciascans, scanswhole, wholexylene
Restek RefinedRestek’s PLOT Column Family —The Benchmark forPerformance!• Innovative bonding process minimizes particle release.• More consistent flow means stable retention times.• Outstanding peak symmetry improves impurity analysis.Visit us at www.restek.com/petrowww.restek.comNext Generation of Porous LayerOpen Tubular (PLOT) Columns• Stabilized particle layers...
Klíčová slova
bond, bondalumina, aluminaplot, plotmxt, mxtcolumns, columnsrestek, restekmapd, mapdporous, porousfused, fusedcfc, cfcsilica, silicacolumn, columngas, gasphases, phaseskcl
PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
2019|Agilent Technologies|Aplikace
PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch• PAMS analysis in a single run.• No cryogenic cooling.3Rt-Alumina BOND/MAPD (FID)45126.00 6.50 7.007.508.00 8.50 9.00 9.50 10.00 10.50 11.00 11.50 12.00 12.50 13.00 13.50 14.00 14.50...
Klíčová slova
ethyltoluene, ethyltoluenediethylbenzene, diethylbenzenexylene, xylenescan, scanmapd, mapdmin, mincyclopentane, cyclopentanefid, fidmethylcyclopentane, methylcyclopentaneisoprene, isoprenepreconcentrator, preconcentratorisopentane, isopentanemethylcyclohexane, methylcyclohexaneisobutane, isobutaneundecane