Analysis of chlorinated and nitroaromatic compounds
Aplikace | 2016 | Trajan ScientificInstrumentace
GC/MSD, GC kolony, Spotřební materiál
ZaměřeníVýrobceTrajan Scientific
Klíčová slovanitroaromatic, temperature, injection, carrier, pentachlorophenol, hexachlorobenzene, chlorinated, velocity, sim, flow, gas, liner, constant, final, column, initial, average, linear, full, scan, part, type, components, detector, number, volume, mode, rate, phase, note, compounds, application, analysis, sample
Podobná PDF
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of USEPA 8270 mix SolGel-1msTM Column part number 054795 Phase SolGel-1msTM Carrier gas flow 1.1 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Sample 10 ppm in methanol Injection mode Splitless Initial…
Klíčová slova
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzoanthracene, anthracenepyrene, pyrenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoletemperature, temperatureinjection, injectionazobenzene
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of USEPA 8270 mix BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 1.1 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Sample 5 ppm solution Injection mode Splitless Initial temperature…
Klíčová slova
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzoanthracene, anthracenepyrene, pyrenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoletemperature, temperatureinjection, injectionazobenzene
Analysis of chlorinated and nitroaromatic compounds
2016|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of chlorinated and nitroaromatic compounds BPX35 Column part number 054701 Phase BPX35 Carrier gas flow 1.8 mL/min Column 30 m x 0.25 mm x 0.25 µm Constant flow On Sample 10 ppm in methanol Average linear velocity…
Klíčová slova
nitroaromatic, nitroaromatictemperature, temperatureinjection, injectioncarrier, carrierpentachlorophenol, pentachlorophenolhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simflow, flowgas, gasliner, linerconstant, constantfinal, finalcolumn
Analysis of polynuclear aromatic hydrocarbons (PAH)
2016|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of polynuclear aromatic hydrocarbons (PAH) SolGel-1msTM Column part number 054795 Phase SolGel-1msTM Carrier gas flow 1.7 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Sample 100 ppm in dichloromethane Average linear velocity…
Klíčová slova
benzo, benzofluoranthene, fluoranthenepyrene, pyreneanthracene, anthracenepolynuclear, polynucleartemperature, temperatureinjection, injectioncarrier, carrierpah, pahphenanthrene, phenanthrenechrysene, chrysenevelocity, velocityaromatic, aromaticsim, simflow