GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

Analysis of organochlorine pesticides (USEPA 608.1)

Aplikace | 2016 | Trajan ScientificInstrumentace
GC/MSD, GC kolony, Spotřební materiál
Zaměření
Výrobce
Trajan Scientific
Klíčová slova
PDF verze ke stažení a čtení
 

Podobná PDF

Toggle
Analysis of USEPA 502.2 mix
Analysis of USEPA 502.2 mix
2016|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of USEPA 502.2 mix BPX5 Column part number 054122 Phase BPX5 Carrier gas flow 1.8 mL/min Column 30 m x 0.25 mm x 1.0 μm Constant flow On Sample 200 ppm in methanol Average linear velocity 35…
Klíčová slova
xylene, xylenebutylbenzene, butylbenzenebenzene, benzenetemperature, temperatureinjection, injectionisopropyltoluene, isopropyltoluenedibromomethane, dibromomethanebromobenzene, bromobenzenecarrier, carriertetrachloroethene, tetrachloroetheneisopropylbenzene, isopropylbenzenetrichloroethene, trichloroethenepropylbenzene, propylbenzenedibromochloromethane, dibromochloromethanebromodichloromethane
Analysis of pine oil
Analysis of pine oil
2017|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of pine oil BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 1.0 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Initial temperature 40°C, 1 min Average linear velocity 36 cm/sec…
Klíčová slova
pine, pineflow, flowcarrier, carriervelocity, velocityvent, venttemperature, temperatureinjection, injectiongas, gasliner, linerpurge, purgeconstant, constantoil, oilfinal, finalcolumn, columninitial
Analysis of eucalyptus oil BPX5
Analysis of eucalyptus oil BPX5
2017|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of eucalyptus oil BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 1.0 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Initial temperature 40°C, 1 min Average linear velocity 36 cm/sec…
Klíčová slova
eucalyptus, eucalyptusflow, flowcarrier, carriervelocity, velocityvent, venttemperature, temperatureinjection, injectiongas, gasliner, linerpurge, purgeconstant, constantoil, oilfinal, finalcolumn, columninitial
Analysis of nutmeg oil
Analysis of nutmeg oil
2017|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of nutmeg oil BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 1.0 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Initial temperature 40°C, 1 min Average linear velocity 36 cm/sec…
Klíčová slova
phellandrene, phellandreneterpinene, terpinenenutmeg, nutmegsafrole, safrolesabinene, sabineneterpinolene, terpinolenehydrate, hydratecymene, cymeneflow, flowcarrier, carrierlimonene, limonenetrans, transvelocity, velocityvent, venttemperature
Další projekty
LCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.