GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

Restek’s PLOT Column Family

Aplikace | 2019 | RestekInstrumentace
GC, GC kolony, Spotřební materiál
Zaměření
Průmysl a chemie
Výrobce
Agilent Technologies, Restek
Klíčová slova
PDF verze ke stažení a čtení
 

Podobná PDF

Toggle
Alumina BOND/MAPD PLOT Columns
2013|Restek|Brožury a specifikace
Restek Refined ® Analyze Trace Polar Hydrocarbons More Accurately and Reliably With Alumina BOND/MAPD PLOT Columns! • Reproducible, predictable responses for reduced calibration frequency. • Exceptional sample loading capacity, which improves resolution and response. • Highest temperature stability—application range extended…
Klíčová slova
mapd, mapdalumina, aluminabond, bondsulfinert, sulfinertrestek, restekstainless, stainlessmxt, mxtsteel, steeltreated, treatedacetylene, acetylenekit, kitpeakarea, peakareafilter, filterplot, plotcolumns
Petrochemical Applications Extending the Power of Stabilized PLOT Column Technology to Process GC Analyzers By Jaap de Zeeuw, Rick Morehead, Tom Vezza, and Gary Stidsen Recent advances in PLOT column technology that were first developed in fused silica have now…
Klíčová slova
mxt, mxtplot, plotmethane, methanediethylether, diethyletherrestek, restekoven, ovencarrier, carriersplit, splitpeaks, peaksdetector, detectorbond, bondcolumn, columnvent, ventacetone, acetonehexane
GC Columns Guidebook
2024|Shimadzu|Příručky
C184-E037E Gas Chromatograph Series Columns GC Columns Guidebook Contents Capillary Columns Column Selection Guide Cross-Reference P. 3 P. 4 High-Performance Columns SH-I-1MS SH-I-5MS SH-I-1HT SH-I-5HT SH-I-5Sil MS SH-I-XLB SH-I-17 SH-I-35Sil MS SH-I-17Sil MS SH-I-PAH SH-I-624Sil MS SH-I-1301Sil MS SH-I-SVOC MS…
Klíčová slova
columns, columnsguard, guardcapillary, capillarymetalx, metalxpolysiloxane, polysiloxanebond, bonddeactivation, deactivationalumina, aluminapolarwax, polarwaxwax, waxpeaks, peakscolumn, columnphase, phaseclp, clpproprietary
Application and Limitation of using Adsorbents as Stationary Phases in Gas Chromatography for the Separation of Volatile Compounds Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Adsorbents have unique separation characteristics. The adsorption process allows very volatile components to be…
Klíčová slova
alumina, aluminaplot, plotporous, porouscolumns, columnsrestriction, restrictionpolymers, polymersmolsieve, molsievepolar, polaradsorbents, adsorbentsbond, bondhigher, highercoating, coatingseparation, separationlayer, layerselectivity
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.