Selecting the Right Inlet Liner for Efficient Sample Transfer

 

Podobná PDF

Toggle
Get Your GC Methods In-Line with the Correct Liner
2022|Agilent Technologies|Prezentace
Get Your GC Methods In-Line with the Correct Liner Mark Sinnott January 20, 2022 1 DE33650537 Agenda Liners General Considerations Wool, no wool, tapers, frits etc. Goals of sample introduction Split injection over-view Liner selection Splitless injection over-view Liner selection…
Klíčová slova
wool, woolliner, linerliners, linersfrit, fritglass, glasssplitless, splitlesssplit, splittaper, taperinjections, injectionsinjection, injectionget, getcorrect, correctinlet, inletdimpled, dimpledfritted
Understanding the GC Inlet: Which Type is Most Appropriate for your Method? Mark Sinnott Agilent Technologies Application Engineer April 22, 2021 1 DE44305-5966666667 Sample Injection Goals •Introduce sample into the column •Reproducible •Minimize efficiency losses •Representative of sample Page 2…
Klíčová slova
splitless, splitlesssplit, splitinlet, inletliner, linervent, ventsolvent, solventpulsed, pulsedseptum, septumcolumn, columninjections, injectionscold, coldinjection, injectionpurge, purgediscrimination, discriminationliners
The picture can't be display ed. Fundamentals and Troubleshooting of the Split/Splitless Inlet Rachael Ciotti GCMS Applications Scientist Shannon Coleman GC & GCMS Applications Scientist Kirk Lokits GCMS Applications Scientist DE3988773148 Split/Splitless Inlet GC Sample Introduction Kirk Lokits, Ph.D. Agilent…
Klíčová slova
split, splitliner, linersplitless, splitlessinjection, injectioninlet, inletwool, woolliners, linerspurge, purgevent, ventseptum, septumglass, glasssample, samplebackflash, backflashinjections, injectionscolumn
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path Agilent Inert Flow Path solutions Ensuring an Inert Flow Path from Injection Through Detection Is Critical—and Now, Easy to Achieve As regulatory agencies drive limits of detection lower…
Klíčová slova
inert, inertagilent, agilentultra, ultrapath, pathliners, linersultimetal, ultimetalplus, plusflow, flowinlet, inletinertness, inertnessyour, yourdeactivation, deactivationmetal, metalflexible, flexiblegold