Agilent J&W DB-5Q and HP-5Q GC columns
Brožury a specifikace | 2024 | Agilent TechnologiesInstrumentace
Gas chromatography–mass spectrometry (GC/MS) is a cornerstone of analytical chemistry for trace-level and multiclass analyte analysis. Column characteristics such as bleed, inertness, durability, and selectivity directly impact data quality, sensitivity, and laboratory throughput. The Agilent J&W 5Q GC columns represent a new benchmark in GC/MS column technology, addressing these critical performance factors.
This note summarizes the design, evaluation, and performance of Agilent J&W 5Q GC columns, highlighting advances in bleed reduction, inertness, conditioning speed, durability, and selectivity compatibility with existing methods and instruments.
Performance was assessed through:
Instrumentation included various Agilent GC systems (7890, 8890, 8850, Intuvo 9000) with FID and MS detectors, hydrogen-compatible sources, and Inert Flow Path configurations.
Adoption of Agilent J&W 5Q GC columns delivers:
Emerging opportunities include integration with hydrogen carrier workflows using HydroInert sources, broader adoption of Inert Flow Path solutions, and further improvements in direct-heating GC technology. Continued deactivation chemistry innovations will push detection limits lower and expand multiclass analyte capabilities.
The Agilent J&W 5Q GC columns set a new standard in GC/MS analysis by delivering ultra low-bleed, ultra inert performance, rapid conditioning, and robust durability, all while maintaining method compatibility and broad instrument support. These attributes collectively enhance laboratory productivity, data quality, and method flexibility.
Spotřební materiál, GC kolony
ZaměřeníVýrobceAgilent Technologies
Souhrn
Importance of the Topic
Gas chromatography–mass spectrometry (GC/MS) is a cornerstone of analytical chemistry for trace-level and multiclass analyte analysis. Column characteristics such as bleed, inertness, durability, and selectivity directly impact data quality, sensitivity, and laboratory throughput. The Agilent J&W 5Q GC columns represent a new benchmark in GC/MS column technology, addressing these critical performance factors.
Objectives and Overview
This note summarizes the design, evaluation, and performance of Agilent J&W 5Q GC columns, highlighting advances in bleed reduction, inertness, conditioning speed, durability, and selectivity compatibility with existing methods and instruments.
Methodology and Instrumentation
Performance was assessed through:
- High-temperature bleed tests at 330–350 °C using FID detection to compare bleed profiles among 5Q and conventional 5 ms columns.
- Mass spectral bleed profiling to quantify siloxane ion interference (m/z 207, 281).
- Ultra Inert performance evaluation using UBER One test mixture of active compounds to assess peak symmetry and sensitivity.
- Durability tests including conditioning time to stable baseline and >150 injections of a pesticide mix in soil matrix to monitor peak shape retention.
- Selectivity matching via analysis of semivolatile multicomponent mixes on 5Q and DB-5ms UI columns.
Instrumentation included various Agilent GC systems (7890, 8890, 8850, Intuvo 9000) with FID and MS detectors, hydrogen-compatible sources, and Inert Flow Path configurations.
Main Results and Discussion
- Ultra Low-Bleed: 5Q columns exhibited significantly lower bleed at 330–350 °C, resulting in stable baselines and reduced spectral interference, enhancing integration accuracy at trace levels.
- Reduced Siloxane Ions: Bleed spectra showed marked decline in m/z 207 and 281 signals compared to conventional columns, preserving spectral fidelity.
- Ultra Inert Performance: UBER One tests demonstrated superior peak symmetry and sensitivity for acidic and basic analytes, enabling reliable quantitation of reactive compounds.
- Fast Conditioning and Durability: Columns reached stable baselines in under 2 hours at 350 °C and maintained peak shape over more than 150 soil-matrix injections without shifting or degradation.
- Selectivity Matching: Retention times on 5Q columns aligned with existing 5 ms and 5 ms UI methods, facilitating seamless method transfer and retention time locking.
- Instrument Compatibility: Available across DB and HP families, in various lengths and diameters for conventional, hydrogen, and backflushing applications, including smart key and Intuvo formats.
Benefits and Practical Applications
Adoption of Agilent J&W 5Q GC columns delivers:
- Enhanced sensitivity and data accuracy for trace analysis.
- Reduced downtime and maintenance through durable, fast-conditioning columns.
- Streamlined method development via selectivity consistency.
- Flexibility across carrier gases (He, H2) and GC/MS platforms.
Future Trends and Potential Applications
Emerging opportunities include integration with hydrogen carrier workflows using HydroInert sources, broader adoption of Inert Flow Path solutions, and further improvements in direct-heating GC technology. Continued deactivation chemistry innovations will push detection limits lower and expand multiclass analyte capabilities.
Conclusion
The Agilent J&W 5Q GC columns set a new standard in GC/MS analysis by delivering ultra low-bleed, ultra inert performance, rapid conditioning, and robust durability, all while maintaining method compatibility and broad instrument support. These attributes collectively enhance laboratory productivity, data quality, and method flexibility.
Obsah byl automaticky vytvořen z originálního PDF dokumentu pomocí AI a může obsahovat nepřesnosti.
Podobná PDF
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path - Agilent Inert Flow Path solutions
2020|Agilent Technologies|Brožury a specifikace
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path Agilent Inert Flow Path solutions Ensuring an Inert Flow Path from Injection Through Detection Is Critical—and Now, Easy to Achieve As regulatory agencies drive limits of detection lower…
Klíčová slova
inert, inertagilent, agilentultra, ultrapath, pathliners, linersultimetal, ultimetalplus, plusflow, flowinlet, inletinertness, inertnessdeactivation, deactivationyour, yourmetal, metalflexible, flexiblegold
Agilent Intuvo 9000 GC System Columns and Supplies
2019|Agilent Technologies|Brožury a specifikace
Agilent Intuvo 9000 GC System Columns and Supplies Innovation with purpose 2 Agilent Essential Chromatography and Spectroscopy Catalog Series Agilent Intuvo 9000 GC System Agilent Intuvo—Innovation with Purpose Agilent has broken new ground in gas chromatography with the Agilent Intuvo…
Klíčová slova
intuvo, intuvoinert, inertagilent, agilentultra, ultracolumns, columnsdescription, descriptionchips, chipsspecialty, specialtyyour, youradm, admlength, lengthliners, linersguard, guardservice, servicephase
How Does Bleed Impact GC/MS Data and How Can It Be Controlled?
2024|Agilent Technologies|Technické články
Technical Overview How Does Bleed Impact GC/MS Data and How Can It Be Controlled? Introduction Understanding column bleed Column bleed remains one of the most commonly observed yet misunderstood aspects of mass spectrometry (MS) data. Bleed elevates chromatographic baselines and…
Klíčová slova
inlet, inletbleed, bleedcolumn, columnconnection, connectiongas, gastemperature, temperatureoven, ovenflow, flowuber, ubermake, makepurge, purgebaseline, baselineseptum, septumoutlet, outletsaver
Agilent Inert Flow Path Solutions - Quick Reference Guide
2021|Agilent Technologies|Příručky
Quick Reference Guide Agilent Inert Flow Path Solutions Agilent’s 7890B, 8890, and 8860 Inert Flow Path Split/Splitless Inlet option ensures the inertness of flow path surfaces, allowing analytes to safely pass from injector to detector. For best trace level analysis,…
Klíčová slova
intuvo, intuvoinert, inertfilm, filmlength, lengthtemp, tempultra, ultralimits, limitsferrule, ferruleultimetal, ultimetalgold, goldagilent, agilentflexible, flexiblemetal, metalwool, woolpath