Agilent 5975B inert Series GC/MS System
Brožury a specifikace | 2006 | Agilent TechnologiesInstrumentace
Gas chromatography coupled with mass spectrometry is a cornerstone of analytical chemistry across pharmaceutical, environmental and industrial laboratories. The ability to perform both electron ionization and chemical ionization in a single system extends the technique's applicability to a wide range of compounds, from volatile organic molecules to polar and labile analytes.
This document profiles the Agilent 5975B inert Series GC/MS, highlighting its design for flexible configuration, automated ionization modes, integrated software tools and long-term reliability. Key goals include demonstrating performance benchmarks, method transfer capabilities and ease of maintenance.
The system combines an MSD with interchangeable EI and CI sources, controlled by Agilent ChemStation software and performance electronics. Configuration options include 6850 or 6890 gas chromatographs, multiple autosampler choices (7683, CTC) and auxiliary detectors. Major components and features:
Sensitivity tests under standardized conditions demonstrate:
The system supports rapid method transfer across sites and instruments, minimizing revalidation through RTL and eMethod protocols. Automated maintenance feedback and tool-free source access reduce downtime.
The 5975B inert Series GC/MS offers:
These strengths address needs in environmental monitoring, forensic toxicology, pharmaceutical QC and petrochemical analysis.
Advances may include further automation of sample introduction (microfluidics, flow controllers), expanded cloud-based method sharing, integration with 21 CFR 11 compliant platforms and enhanced deconvolution algorithms for even more complex matrices. Continuous improvements in ion optics and detector technologies will drive sensitivity and selectivity to new levels.
The Agilent 5975B inert Series GC/MS represents a versatile, high-performance solution for modern analytical challenges. Its combination of robust hardware, advanced software and automation features ensures reliable results, efficient workflows and easy method transfer across laboratories.
Agilent Technologies 5975B inert Series GC/MS System Data Sheet (2006)
GC/MSD, GC/SQ
ZaměřeníVýrobceAgilent Technologies
Souhrn
Importance of the Topic
Gas chromatography coupled with mass spectrometry is a cornerstone of analytical chemistry across pharmaceutical, environmental and industrial laboratories. The ability to perform both electron ionization and chemical ionization in a single system extends the technique's applicability to a wide range of compounds, from volatile organic molecules to polar and labile analytes.
Objectives and Overview
This document profiles the Agilent 5975B inert Series GC/MS, highlighting its design for flexible configuration, automated ionization modes, integrated software tools and long-term reliability. Key goals include demonstrating performance benchmarks, method transfer capabilities and ease of maintenance.
Methodology and Instrumentation
The system combines an MSD with interchangeable EI and CI sources, controlled by Agilent ChemStation software and performance electronics. Configuration options include 6850 or 6890 gas chromatographs, multiple autosampler choices (7683, CTC) and auxiliary detectors. Major components and features:
- Inert EI source and optional CI source with automatic gas flow control
- Hyperbolic gold-coated quadrupole heated to 200 °C for mass filtering up to 1050 u
- High-speed electronics enabling up to 10 000 u/s scan and simultaneous SIM/scan acquisition
- Software functions: automated SIM setup, retention-time locking, eMethods, SemiQuant, Deconvolution Reporting Software
- Pumping options: 70 L/s or 262 L/s turbomolecular pump with mechanical roughing pump
Main Results and Discussion
Sensitivity tests under standardized conditions demonstrate:
- EI scan sensitivity of 175:1 S/N for a 1 pg OFN injection
- PCI and NCI modes delivering over 100:1 S/N at low-pg levels
- SIM limits of detection down to femtogram levels with 10:1 S/N
- Mass axis stability better than 0.10 u over 48 hours
- Retention time repeatability below 0.0012 min and area repeatability under 2 % RSD
The system supports rapid method transfer across sites and instruments, minimizing revalidation through RTL and eMethod protocols. Automated maintenance feedback and tool-free source access reduce downtime.
Benefits and Practical Applications
The 5975B inert Series GC/MS offers:
- Flexible ionization modes for broad compound classes
- High throughput with combined SIM/scan workflows
- Enhanced data quality via deconvolution and spectral libraries
- User-friendly software for quantitative and qualitative reporting
- Low cost-of-ownership backed by a ten-year use guarantee
These strengths address needs in environmental monitoring, forensic toxicology, pharmaceutical QC and petrochemical analysis.
Future Trends and Potential Applications
Advances may include further automation of sample introduction (microfluidics, flow controllers), expanded cloud-based method sharing, integration with 21 CFR 11 compliant platforms and enhanced deconvolution algorithms for even more complex matrices. Continuous improvements in ion optics and detector technologies will drive sensitivity and selectivity to new levels.
Conclusion
The Agilent 5975B inert Series GC/MS represents a versatile, high-performance solution for modern analytical challenges. Its combination of robust hardware, advanced software and automation features ensures reliable results, efficient workflows and easy method transfer across laboratories.
References
Agilent Technologies 5975B inert Series GC/MS System Data Sheet (2006)
Obsah byl automaticky vytvořen z originálního PDF dokumentu pomocí AI a může obsahovat nepřesnosti.
Podobná PDF
Agilent 5975C TAD Series GC/MSD System - Data Sheet
2012|Agilent Technologies|Brožury a specifikace
Agilent 5975C TAD Series GC/MSD System Data Sheet GC/MSD Overview The Agilent 5975C TAD Series Gas Chromatograph/Mass Selective Detector (GC/MSD) with the Triple-Axis High Energy Diode (HED) Electron Multiplier (EM) Detector provides the flexibility, capabilities, and performance demanded by modern…
Klíčová slova
sim, simoptional, optionalmsd, msdscan, scanrtl, rtlmass, massaxis, axissource, sourceionization, ionizationelectronic, electronicnoncondensing, noncondensingmethane, methanecontrol, controlsetup, setupmaintenance
Agilent 5977A Series GC/MSD System - Data Sheet
2013|Agilent Technologies|Brožury a specifikace
Agilent 5977A Series GC/MSD System Data Sheet 5977A GC/MSD Overview The Agilent 5977A Series GC/MSD builds on a 45-year tradition of leadership and innovation, bringing together the technologies of the industry’s best GC and MS systems. This advanced instrument provides…
Klíčová slova
sim, simmasshunter, masshunteroptional, optionalmsd, msdscan, scanmass, massinert, inertsource, sourcehelium, heliumnci, ncipci, pciclassic, classicnoncoated, noncoatedcontrol, controlcarrier
Agilent Agilent 5973 inert GC/MS System - Data Sheet
2004|Agilent Technologies|Brožury a specifikace
Agilent 5973 inert GC/MS System Data Sheet GC/MS The Agilent 5973 inert Gas Chromatograph/Mass Spectrometer (GC/MS) is the latest in the 5973 series of mass selective detectors (MSDs). This model provides improved inertness for reactive compounds resulting in better peak…
Klíčová slova
rtl, rtloptional, optionalsensitivity, sensitivitymass, masssim, simautotunes, autotunesnoncondensing, noncondensingcompatible, compatibleflip, flipmicrofluidics, microfluidicssource, sourcepressure, pressurehyperbolic, hyperbolictemperature, temperaturenci
Agilent 5977C GC/MSD System
2022|Agilent Technologies|Brožury a specifikace
Data Sheet Agilent 5977C GC/MSD System The Agilent 8890/5977C Series gas chromatograph/mass selective detector (GC/MSD) builds on a tradition of leadership in GC and MS technology, with the world’s most competitive performance and productivity features. Agilent GC/MSD system features Agilent…
Klíčová slova
idl, idlturbo, turboextractor, extractoroptional, optionalmass, massscan, scanpump, pumpspecifications, specificationsagilent, agilentstainless, stainlesssource, sourcesim, simsteel, steelhydroinert, hydroinerthes