Expanding the Molecular Weight Range of Whole Air Sampling with Stainless Steel Canisters using Active SPME Sample Preparation and GCMS Analysis
Aplikace | 2010 | ENTECHInstrumentace
GC/MSD, SPME, Termální desorpce, Příprava vzorků, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceAgilent Technologies, ENTECH
Klíčová slovaspme, canisters, canister, thermal, bakeout, trap, desorb, rotary, active, compounds, air, tenax, dean, eliminated, thermally, silonite, gcms, ppbv, stage, weight, whole, has, molecular, direct, desorption, introduced, labile, virtually, sampling, trapping, vapor, rather, remedied, casteel, sub, minican, stainless, utilizing, cardin, preconcentrating, steel, although, actual, more, range, presented, absorptive, field, investigator, stemming
Podobná PDF
Formaldehyde and VOC’s in Indoor Air Quality Determinations by GCMS
2007|Agilent Technologies|Aplikace
Formaldehyde and VOC’s in Indoor Air QualityDeterminations by GCMSApplication Note: 101Application Note:A-3727-01AuthorsDan CardinTom RobinsonEntech Instrurments, IncSimi Valley, CA 93065AbstractA stainless steel canister based method has beendeveloped to measure both VOCs and lightcarbonyls in indoor air using a single GCMSanalysis.MiniCanTM stainless...
Klíčová slova
formaldehyde, formaldehydeppbv, ppbvair, airpropanal, propanalcanister, canisterindoor, indoorcarbonyl, carbonylgcms, gcmsminicans, minicanssilonite, siloniteacetone, acetoneacetalde, acetaldeformalde, formaldesampling, samplingminican
Improving Canister Sampling Accuracy and Reliability Using Helium Diffusion Sampling into Silonite Coated Stainless Steel Canisters
|Agilent Technologies|Aplikace
Improving Canister Sampling Accuracy andReliability Using Helium Diffusion Samplinginto Silonite Coated Stainless Steel CanistersINSTRUMENTSINC.Application Note:A-3731-01AuthorsDaniel B. CardinThomas X. RobinsonDaniel J. CardinEntech Instruments, Inc.Simi Valley, CA 93065AbstractA new, simplified approach for filling air samplingcanisters during monitoring of Environmentalpollutants in air is...
Klíčová slova
sampling, samplingcanister, canisterhds, hdsdiffusion, diffusioncanisters, canistersair, airhelium, heliumgauge, gaugeover, oversampler, samplervacuum, vacuumsilonite, siloniteatmospheric, atmosphericvac, vaccontrollers
A Simple, More Reliable Time Integrated Whole Air Sampling Approach To EPA Method TO15 Using Helium Diffusion Sampling
|Agilent Technologies|Aplikace
A Simple, More Reliable Time IntegratedWhole Air Sampling ApproachTo EPA Method TO15 Using Helium DiffusionSamplingINSTRUMENTSINC.Application Note:A-3732-01AuthorsThomas X. RobinsonChris CasteelDan CardinEntech Instruments, Inc.Simi Valley, CA 93065AbstractA new, simplified approach for filling air samplingcanisters during monitoring of Environmentalpollutants in air is described....
Klíčová slova
sampling, samplingcanisters, canistersair, airatmospheric, atmosphericcanister, canisterpressure, pressurepropane, propanediffusion, diffusionvacuum, vacuumgauge, gaugesampled, sampledhelium, heliumintegrated, integratedagain, againsimi
5800 Sorbent Pen™ Desorption Unit
2020|ENTECH|Brožury a specifikace
5800 Sorbent Pen™ Desorption UnitCompatibility• Compatible with Agilent®, Thermo Scientific®, andShimadzu® GC/GCMS systemsGCGC OvenColumn 1MSTemperature Programming• Two temperature desorption setpoints• Heating rates up to 450 °C/min• Initial temperature 50-350 °C• First desorb temperature 50-350 °C• Second desorb temperature 50-350 °C•...
Klíčová slova
sorbent, sorbentdesorption, desorptionpens, pensentech, entechtenax, tenaxspr, sprthermal, thermalheadspace, headspacesvocs, svocsvase, vasetubes, tubesfeve, fevecarbopack, carbopackrail, railair