Organic SolventsAplikace | | GL Sciences InstrumentaceGC, GC kolony, Spotřební materiálVýrobceGL SciencesKlíčová slova
Podobná PDF
InertSearch for GCTMInertCap® ApplicationsOrganic hydrideData No. GA276-059120Voltt408Analyte1. n-Pentane2. n-Hexane3. Cyclohexane4. n-Heptane5. Benzene6. Methylcyclohexane7. n-Octane8. Toluene9. n-Nonane10. n-Decane11. trans-Decalin12. Naphthalene6345279101112010.1 %(w/v)0.1 %(w/v)1.0 %(w/v)0.1 %(w/v)1.0 %(w/v)5.0 %(w/v)()0.1 %(w/v)Solvent0.1 %(w/v)0.1 %(w/v)1.0 %(w/v)1.0 %(w/v)01020Time (min)2..0121186Volt51.032479100.0101020Time (min)InertSearch for GCTMInertCap® ApplicationsOrganic hydride40Data No. GA276-0591Analyte1. n-Pentane2. n-Hexane3....
Klíčová slova
hydride, hydridevoltt, volttinertsearch, inertsearchinertcap, inertcapvolt, voltapplications, applicationsorganic, organicmin, mincol, coltime, timeanalyte, analytesolvent, solventsize, sizecarrier, carrierdetection
Packed Column Refinery Gas Analysis System Based on the Agilent 7890B GC System and G3507A Large Valve Oven
2013|Agilent Technologies|Aplikace
Packed Column Refinery GasAnalysis System Based on theAgilent 7890B GC System andG3507A Large Valve OvenApplication NoteHydrocarbon Processing IndustryAuthorAbstractRoger L FirorA three-channel system on the Agilent 7890B GC System is used for the determina-Agilent Technologies, Inc.tion of refinery gases. Channel 1,...
Klíčová slova
tcd, tcdsulfide, sulfidehydrogen, hydrogenoxygen, oxygenrga, rgafront, frontethane, ethanecarbon, carbonpcm, pcmmethane, methaneinl, inlfid, fidlvo, lvomonoxide, monoxiderefinery
Fast Refinery Gas Analysis System Based on the Agilent 7890B GC System and G3507A Large Valve Oven Using Micropacked Columns
2013|Agilent Technologies|Aplikace
Fast Refinery Gas Analysis SystemBased on the Agilent 7890B GCSystem and G3507A Large ValveOven Using Micropacked ColumnsApplication NoteHydrocarbon Processing IndustryAuthorAbstractRoger L FirorA three channel system on the Agilent 7890B GC System was used for the determi-Agilent Technologies, Inc.nation of refinery...
Klíčová slova
sulfide, sulfidetcd, tcdrefinery, refineryhydrogen, hydrogenmicropacked, micropackedfront, frontinl, inlcarbonyl, carbonylethane, ethanefid, fidmethane, methaneoven, ovenoxygen, oxygencarbon, carboncolumns
InertSearch for GCTMInertCap® ApplicationsOrganic SolventsData No. GA 284-0644CS2 + 1uVolts20000104+51186129302701020Time (min)ConditionsSystemColumnCol. Cat. No.Col. Temp.Carrier GasInjectionDetectionSample Size: GC-FIDAnalyteQ: InertCapp AQUATIC0.53 mm I.D. x 75 m df = 2.0 μm: 1010-29477: 40 ℃ (5 min hold) - 5 ℃/min - 180 ℃:...
Klíčová slova
uvolts, uvoltsinertsearch, inertsearchinertcap, inertcapsolvents, solventssize, sizeapplications, applicationsorganic, organicanalyte, analytecarrier, carrierdetection, detectioninjection, injectionmin, minconditions, conditionsgas, gassystem