Headspace Analysis of Solvents in Printed Paper
Aplikace | | SCION InstrumentsInstrumentace
GC, GC kolony, Spotřební materiál
ZaměřeníMateriálová analýza
VýrobceSCION Instruments
Klíčová slovascion, propylacetate, propanol, fid, iso, xylene, ethylacetate, instruments, ethylbenzene, netherlands, paper, ethanol, toluene, headspace, unknown, printed, injector, solvents, oven, identification, carrier, note, peak, conditions, gas, application, column, analysis
Podobná PDF
Determination of Halogenated Hydrocarbons in Water
|SCION Instruments|Aplikace
Determination of Halogenated Hydrocarbons in Water Application Note AN0045 SCION GC-HS-MS GC-HS-MS conditions Peak Identification HS 80°C, 30min Injector 170°C, 0.6:1 Sample 14mL +7g Na2SO4 in 20mL vial Column SCION-624MS 60m x 0.32mm x 1.8µm Oven Carrier Gas 45°C (10mins)…
Klíčová slova
scion, sciontrichloronitromethane, trichloronitromethanexylene, xylenetetrachloromethane, tetrachloromethaneinstruments, instrumentstrichlorofluoromethane, trichlorofluoromethaneisopropylbenzene, isopropylbenzenetetrachloroethene, tetrachloroethenetrichloroethene, trichloroethenepropylbenzene, propylbenzenedibromochloromethane, dibromochloromethanehalogenated, halogenatedbromodichloromethane, bromodichloromethanebromoform, bromoformdichloromethane
Analysis of Nitro Compounds
|SCION Instruments|Aplikace
Analysis of Nitro Compounds Application Note AN0056 SCION GC-FID GC-FID conditions Injector 1:100 Sample 1µL Column SCION-1701 30m x 0.25mm x 0.25µm Oven 45°C (3 min) to 280°C at 10°C/min Carrier Gas Helium, 1mL/min Peak Identification 1 2 3 4…
Klíčová slova
scion, scionxylene, xylenefid, fidnitro, nitroinstruments, instrumentschlorobenzene, chlorobenzenestyrene, styreneethylbenzene, ethylbenzenenetherlands, netherlandsbenzene, benzenetoluene, tolueneinjector, injectoroven, ovenidentification, identificationnote
Analysis of Aromatics using SCION-WAXMS GC Column
|SCION Instruments|Aplikace
Analysis of Aromatics using SCION-WAXMS GC Column Application Note AN0039 SCION GC-FID Conditions S/SL 250°C, Split 75mL/min Sample 0.1µL (0.1% cyclohexane) Column SCION-WaxMS 60m x 0.25mm x 0.25µm Oven Programme 55°C to 150°C at 4°C/min Carrier Gas Helium 2.0 bar…
Klíčová slova
scion, scionxylene, xylenefid, fidwaxms, waxmsprogramme, programmeinstruments, instrumentsaromatics, aromaticsethylbenzene, ethylbenzenenetherlands, netherlandsbenzene, benzenetoluene, toluenecolumn, columnoven, ovencarrier, carrieridentification
Analysis of Beer using SCION-WAXMS GC Column
|SCION Instruments|Aplikace
Analysis of Beer using SCION-WAXMS GC Column Application Note AN0040 SCION GC-HS-FID Headspace Conditions Oven 60°C Sample Loop 60°C Transfer Line 100°C Vial Equib Time 20 minutes Fill Pressure 15psi at 50mL/min Inject Time 0.5 minutes GC-FID conditions S/SL Sample…
Klíčová slova
scion, scionisoamyl, isoamylfid, fidsulphide, sulphideethyl, ethylacetate, acetatewaxms, waxmsprogramme, programmeisobutanol, isobutanolinstruments, instrumentsoven, ovenacetaldehyde, acetaldehydebeer, beerformate, formatefill