Carboxen GC PLOT Capillary Columns
Product Information
595 North Harrison Road
Bellefonte, PA 16823-0048 USA
Telephone 800-247-6628 ● 814-359-3441
Fax 800-447-3044 ● 814-359-3044
email: [email protected]
sigma-aldrich.com/supelco
sigma-aldrich.com/supelco
Carboxen GC PLOT Capillary Columns
Supelco PLOT Columns
Supelco PLOT columns are an ideal choice for many permanent gases
and light hydrocarbon analyses in the petrochemical industry.
Supelco PLOT columns are prepared using a proprietary patented
adhesive technology that firmly bonds the adsorbent particles to the
wall of the capillary column. The adhesive also bonds the particles to
each other, eliminating particle loss during routine analysis or rapid
temperature programming. A significant feature of the adhesive is its
high temperature limit, greater than 360 °C, which makes the
operating temperature of the column a function of the particles
used, not the adhesive.
Supelco PLOT columns are individually tested for efficiency, inert-
ness, and retention. Each column is shipped with a chromatogram
demonstrating column performance that can be expected.
Carboxen Capillary PLOT Columns
Carboxen™ PLOT columns are the appropriate choice for permanent
gas mixtures that include permanent gases and C1 to C3 hydrocar-
bons. Carboxen PLOT column chemistry is based on synthetic,
spherical carbon molecular sieves that are synthesized in-house
under carefully controlled conditions. Each Carboxen has a unique
combination of pore size, pore structure, and surface area. These two
features permit analyte separations not possible with other PLOT
columns.
Carboxen-1010
A larger pore structure (7 Å ) and increased number of pores make
Carboxen-1010 PLOT columns the preferred choice over zeolite Mol
Sieve 5A PLOT columns for effectively separating oxygen, nitrogen,
and larger analytes up to C3. Because the Carboxen surface is
hydrophobic, samples containing water do not cause retention time
shifts, eliminating the need for thermal conditioning as necessary
with Mol Sieve 5A PLOT columns.
Carboxen-1006
Carboxen-1006 has a multiporous pore structure. The presence of
large macropores and mesopores allow for effective access of the
7 Å micropores for fast kinetic applications. This unique pore
structure makes Carboxen 1006 suitable for permanent gases and
light hydrocarbons. The inert surface chemistry makes it an excellent
choice for formalin analyses.
Figure A. Transformer Gas Analysis for ASTM Method D3612-96 on Carboxen-1010 PLOT Column
column:
Carboxen-1010 PLOT, 30 m x 0.53 mm I.D. (25467)
oven:
35 °C (7.5 min.) to 250 °C at 24 °C/min.
inj.:
200 °C
det.:
TCD/methanizer-FID, 230 °C
flow rate:
Argon, 3.0 mL/min.
valve:
150 °C
injection:
10.0 µL valve injection
sample:
500 ppm each, transformer gas for ASTM Method D3612-96
G002209
0
2
4
6
8
1
2 3
10
12
14
16
18
20
4
5
6
7
8
9
Min
1.
Hydrogen
2.
Oxygen
3.
Nitrogen
4.
Carbon monoxide
5.
Methane
6.
Carbon dioxide
7.
Acetylene
8.
Ethylene
9.
Ethane
We are committed to the success of our Customers, Employees and Shareholders through leadership in Life Science, High Technology and Service.
®
The SIGMA-ALDRICH Family
®
™
©2003 Sigma-Aldrich Co. Printed in USA. Supelco brand products are sold through Sigma-Aldrich, Inc. Sigma-Aldrich, Inc. warrants that its products conform
to the information contained in this and other Sigma-Aldrich publications. Purchaser must determine the suitability of the product(s) for their particular use.
Additional terms and conditions may apply. Please see reverse side of the invoice or packing slip. Supelco is a registered trademark of Sigma-Aldrich Co.
GFF T403146B
®
Order/Customer Service 800-247-6628, 800-325-3010
Fax 800-325-5052 ● E-mail [email protected]
Technical Service 800-359-3041, 814-359-3041
Fax 800-359-3044, 814-359-5468 ● E-mail [email protected]
SUPELCO ● 595 North Harrison Road, Bellefonte, PA 16823-0048 ● 814-359-3441
sigma-aldrich.com/supelco
Figure B. Permanent Gases with C2 to C4 Hydrocarbons on Carboxen-1006 PLOT Column
column:
Carboxen-1006 PLOT, 30 m x 0.53 mm I.D. (25461)
oven:
35 °C (1.0 min.) to 250 °C at 24 °C/min.
inj.:
200 °C
det.:
TCD, 230 °C
flow rate:
Helium, 10.0 mL/min.
valve:
150 °C
injection:
10.0 µL valve injection
sample:
Permanent gases and C2 to C4 hydrocarbon mix
794-0618
Ordering Information:
Carboxen-1010 PLOT
Dimension
Max. Temp.
Cat. No.
30 m x 0.32 mm I.D.
250 °C
24246
30 m x 0.53 mm I.D.
250 °C
25467
Carboxen-1006 PLOT
Dimension
Max. Temp.
Cat. No.
30 m x 0.32 mm I.D.
250 °C
24241-U
30 m x 0.53 mm I.D.
250 °C
25461
1.
Nitrogen (bulk)
2.
Carbon monoxide (215 ng on column)
3.
Methane (430 ng on column)
4.
Carbon dioxide (215 ng on column)
I.
Water impurity
5.
Acetylene (430 ng on column)
6.
Ethylene (430 ng on column)
7.
Ethane (430 ng on column)
8.
Methyl acetylene (215 ng on column
9.
Propylene (215 ng on column
10.
Propane (215 ng on column)
11.
n-Butane (215 ng on column)
1
2
3
4
5
6
7
8
9
10
11
0
4
8
12
16
Min
Trademark
Carboxen - Sigma-Aldrich Co.