Blood Alcohol Analysis on Rtx®-BAC Plus 1
Aplikace | | RestekInstrumentace
GC, HeadSpace, GC kolony, Spotřební materiál
ZaměřeníForenzní analýza a toxikologie
VýrobceAgilent Technologies, Restek, Tekmar Teledyne
Klíčová slovaPodobná PDF
Blood Alcohol Analysis on Rtx®-BAC Plus 2
|Agilent Technologies|Aplikace
Blood Alcohol Analysis on Rtx®-BAC Plus 2 1 - Run time less than 3 minutes! - Increased resolution of ethanol from other peaks of interest. 4 1. 2. 3. 4. 5. 6. 7. Peaks Acetaldehyde Methanol Ethanol Acetone Isopropanol tert-Butanol…
Klíčová slova
ethanol, ethanolmake, makeacetaldehyde, acetaldehydebutanol, butanolisopropanol, isopropanoltert, tertacetone, acetoneloop, loopgas, gasheadspace, headspacemethanol, methanolincreased, increasedoven, oventransfer, transferpeaks
BAC Resolution Control Standard t-B on Rtx®-BAC Plus 1 and Plus 2 Column Set
|Agilent Technologies|Aplikace
BAC Resolution Control Standard t-B on Rtx®-BAC Plus 1 and Plus 2 Column Set Rtx®-BAC Plus 1 2 Peaks New resolution control standard! 1. 2. 3. 4. 5. 6. 5 1 0.6 BAC Plus 1 RT (min.) 0.801 0.848 1.012…
Klíčová slova
acetaldehyde, acetaldehydebutanol, butanolisopropanol, isopropanolacetone, acetoneethanol, ethanolnotes, notesloop, loopgas, gasheadspace, headspacemethanol, methanolmake, makeoven, ovenpeaks, peakscarrier, carriercolumns
Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns
2018|Agilent Technologies|Brožury a specifikace
Restek GC LC Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood • Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. • Robust and reproducible column…
Klíčová slova
restek, restekleak, leakpeaks, peaksadaptor, adaptoruniversal, universalalcohol, alcoholglycol, glycolessentials, essentialscharger, chargertailing, tailingacetone, acetoneblood, blooddescription, descriptionthread, threadreference
BAC Resolution Control Standard n-P on Rtx®-BAC Plus 1 and Plus 2 Column Set
|Agilent Technologies|Aplikace
BAC Resolution Control Standard n-P on Rtx®-BAC Plus 1 and Plus 2 Column Set Rtx®-BAC Plus 1 Peaks 2 1. 2. 3. 4. 5. 6. New resolution control standard! Conc. (μg/mL) 50 50 50 50 50 50 Methanol Acetaldehyde Ethanol…
Klíčová slova
acetaldehyde, acetaldehydeisopropanol, isopropanolacetone, acetoneethanol, ethanolnotes, notesloop, loopheadspace, headspacemethanol, methanoloven, ovenpeaks, peakssample, samplecarrier, carriercolumns, columnsnew, newresolution