Methanol in Crude Oil Analysis According to ASTM D7059-04
Aplikace | 2020 | SCION InstrumentsInstrumentace
GC
ZaměřeníPrůmysl a chemie
VýrobceSCION Instruments
Klíčová slovamethanol, scion, ploq, crude, oil, ratio, mean, internal, standard, dev, ppm, repeatability, subscribes, std, injector, split, instruments, level, min, toluene, efc, loq, doped, splitless, high, system, according, concentration, low, analyser, series, backflushed, rel, linearity, limit, catalysts, amount, response, analysis, pooled, ssl, straight, astm, converted, both, flush, configurations, block, netherlands, oils
Podobná PDF
Determination of Methanol in Crude Oils According to ASTM D7059-04 Using the Clarus 680 GC with S-Swafer Micro- Channel Flow Technology
2010|PerkinElmer|Aplikace
a p p l i c at i o n N o t e Gas Chromatography Author Andrew Tipler PerkinElmer, Inc. Shelton, CT 06484 USA Determination of Methanol in Crude Oils According to ASTM D7059-04 Using the Clarus 680 GC…
Klíčová slova
swafer, swaferbackflushing, backflushingcrude, crudeprecolumn, precolumnrestrictor, restrictorcolumn, columninjector, injectorsplitting, splittingpressure, pressuregas, gassample, sampleliner, lineroil, oilbackflush, backflushdetector
Investigation of the Unique Selectivity and Stability of Agilent GS-OxyPLOT Columns
2008|Agilent Technologies|Aplikace
Investigation of the Unique Selectivity and Stability of Agilent GS-OxyPLOT Columns Application Gas Chromatography Authors Yun Zou and Min Cai Agilent Technologies (Shanghai) Co. Ltd. 412 Ying Lun Road Waigaoqiao Free Trade Zone Shanghai 200131 P.R. China Abstract The stationary…
Klíčová slova
oxyplot, oxyplotmethanol, methanolhydrocarbons, hydrocarbonsmin, mincolumn, columnpentadecane, pentadecanenormal, normalrsd, rsdwater, waterconditioning, conditioninggas, gasalcohol, alcoholinjection, injectioninlet, inletsize
Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059
2004|Agilent Technologies|Aplikace
Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application Petrochemical Author James D. McCurry Agilent Technologies 2850 Centerville Road Wilmington, DE 19808 USA Abstract A…
Klíčová slova
crude, crudeoil, oillowox, lowoxmethanol, methanoldeans, deansswitch, switchepc, epcfluidic, fluidicmicro, microcolumn, columncontrol, controlpcm, pcmanalysis, analysisinlet, inlettrace
Oxygenates in Fuels –Analysis Solutions From Trace Levels to Ethanol Fuels
2010|Agilent Technologies|Prezentace
Oxygenates in Fuels – Analysis Solutions From Trace Levels to Ethanol Fuels Page 1 James D. McCurry Senior Scientist Agilent Technologies Wilmington, DE USA October 13, 2010 Application Summary There is a need to measure trace oxygenates in: • Feedstocks…
Klíčová slova
oxygenates, oxygenatesethanol, ethanolgasoline, gasolineastm, astmoxygenate, oxygenateswitch, switchfluidic, fluidicfuel, fuelmethanol, methanolepc, epcether, ethercft, cftaux, auxtrace, tracedipe