Agilent 7890B GC Supplies - Quick reference guide
Příručky | 2018 | Agilent TechnologiesInstrumentace
High-quality consumables and spare parts are essential for consistent, reliable gas chromatographic analysis. Proper vials, inlet liners, septa and filters prevent sample loss, leaks, and contamination, while detector and transfer line components ensure stable detector performance. Using genuine, standardized supplies minimizes downtime, maintains method reproducibility and extends instrument life.
This reference guide compiles the most frequently ordered supplies for the Agilent 7890B GC system. It aims to help laboratories quickly identify required parts, plan routine maintenance and reduce unexpected instrument failures. The document categorizes consumables by application area, provides part numbers and highlights performance-optimized options.
The supply list was developed in collaboration with application scientists and service engineers based on field data, order histories and user feedback. It covers:
The primary instrument is the Agilent 7890B gas chromatograph, including its flame ionization detector (FID) and mass selective detector (MSD) modules.
By standardizing on genuine Agilent consumables, laboratories achieve:
These consumables support a wide range of applications in environmental testing, petrochemicals, food safety, clinical research and QA/QC workflows.
Innovations in consumable design and supply management are emerging:
These advances will further boost system uptime, data quality and overall lab efficiency.
A well-curated inventory of genuine Agilent 7890B GC supplies is vital for achieving reliable chromatographic results. By selecting the appropriate vials, filters, inlet components and detector parts, laboratories can maintain optimal system performance, minimize maintenance incidents and ensure reproducible data across diverse analytical applications.
GC, Spotřební materiál
ZaměřeníVýrobceAgilent Technologies
Souhrn
Significance of GC Consumables and Accessories
High-quality consumables and spare parts are essential for consistent, reliable gas chromatographic analysis. Proper vials, inlet liners, septa and filters prevent sample loss, leaks, and contamination, while detector and transfer line components ensure stable detector performance. Using genuine, standardized supplies minimizes downtime, maintains method reproducibility and extends instrument life.
Objectives and Overview of the Document
This reference guide compiles the most frequently ordered supplies for the Agilent 7890B GC system. It aims to help laboratories quickly identify required parts, plan routine maintenance and reduce unexpected instrument failures. The document categorizes consumables by application area, provides part numbers and highlights performance-optimized options.
Applied Methodology and Instrumentation
The supply list was developed in collaboration with application scientists and service engineers based on field data, order histories and user feedback. It covers:
- Gas introduction and filtration: Gas Clean kits and replacement filters
- Sample introduction: Vials and crimp or screw caps with PTFE/silicone septa
- Inlet components: Ultra inert liners, split/splitless liners, septa, O-rings, gold seals
- Detector accessories: FID jets, ignitors, collector bodies; MSD transfer line nuts and ferrules
- Diagnostics tools: Flow meters and electronic leak detectors
The primary instrument is the Agilent 7890B gas chromatograph, including its flame ionization detector (FID) and mass selective detector (MSD) modules.
Main Categories of Supplies and Key Features
- Sample Vials and Caps: 2 mL A-Line crimp top or screw top vials in clear or amber, PTFE/silicone septa in crimp or screw caps for reliable sealing.
- Gas Clean Filters: Carrier gas, oxygen, moisture and hydrocarbon filters ensure ultra-pure gas streams to protect columns and detectors.
- Inlet Liners and Sealing Components: Ultra inert liners with pre-installed O-rings, glass wool options for split and splitless modes; BTO, Advanced Green and long-life septa rated for up to 400 °C; fluorocarbon O-rings and gold seals for leak-free operation.
- FID Supplies: Short and long jets in various tip sizes and materials, ignitor assemblies, collector bodies including Hastelloy options and insulators to maintain stable flame conditions.
- MSD Supplies: Transfer line interface nuts (brass, self-tightening), ferrules in graphite, Vespel and flexible metal tailored to column ID, EI filaments and diagnostic tools for quick troubleshooting.
Benefits and Practical Applications
By standardizing on genuine Agilent consumables, laboratories achieve:
- Reduced risk of leaks and sample degradation
- Lower baseline noise and chromatographic bleed
- Improved detector sensitivity and stability
- Enhanced column life and reproducibility across batches
- Streamlined maintenance scheduling and inventory management
These consumables support a wide range of applications in environmental testing, petrochemicals, food safety, clinical research and QA/QC workflows.
Future Trends and Potential Utilizations
Innovations in consumable design and supply management are emerging:
- Smart consumables with RFID/barcode tracking to automate inventory control and maintenance alerts.
- Enhanced inert coatings in liners and ferrules for ultra-trace analysis of reactive compounds.
- Integration of IoT-enabled diagnostics tools to predict component wear and preemptively schedule replacements.
- Development of more durable septa materials and multi-use inlet components to reduce waste and cost.
These advances will further boost system uptime, data quality and overall lab efficiency.
Conclusion
A well-curated inventory of genuine Agilent 7890B GC supplies is vital for achieving reliable chromatographic results. By selecting the appropriate vials, filters, inlet components and detector parts, laboratories can maintain optimal system performance, minimize maintenance incidents and ensure reproducible data across diverse analytical applications.
Obsah byl automaticky vytvořen z originálního PDF dokumentu pomocí AI a může obsahovat nepřesnosti.
Podobná PDF
Agilent 8890 and 8860 GC Supplies - Quick Reference Guide
2019|Agilent Technologies|Brožury a specifikace
Quick Reference Guide Agilent 8890 and 8860 GC Supplies Agilent supplies for Agilent instruments Agilent is committed to optimizing your laboratory’s productivity, so we have produced this list of the most commonly ordered supplies and parts for the 8890 and…
Klíčová slova
yes, yessupplies, suppliespart, partnumber, numberclean, cleangraphite, graphitesepta, septawax, waxgas, gaswool, wooladm, admfilter, filterwasher, washerseal, sealmsd
Agilent GC AND GC/MS - Catalog Consumables and Spare Parts
2016|Agilent Technologies|Ostatní
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Klíčová slova
supplies, suppliesagilent, agilentparts, partscrosslab, crosslabdescription, descriptionoem, oemnut, nutinlet, inletliners, linerssepta, septaferrule, ferrulecolumn, columnneedle, needlestick, stickassembly
Better Connections - Agilent GC inlet resource guide
2021|Agilent Technologies|Příručky
Better Connections, Better Results with Your Agilent GC System GC inlet resource guide Here’s What’s Inside Introduction Septa Troubleshooting Ordering Information Ferrules Troubleshooting Ordering Information 2 3 4 4 7 8 9 13 Column Nuts Ordering Information Liners 14 15…
Klíčová slova
liner, linerproblem, probleminlet, inletferrules, ferrulescolumn, columnnormal, normalgraphite, graphitenut, nutliners, linersnuts, nutssepta, septaferrule, ferruleagilent, agilentwool, woolglass
8890 Gas Chromatography (GC) System with 7693A Automatic Liquid Sampler (Essential Instrument Supplies)
2025|Agilent Technologies|Ostatní
Essential Instrument Supplies Agilent technical experts have compiled a list of recommended supplies that you should consider using with your new instrument in order to keep your lab operational without any disruptions and to achieve optimal performance. 8890 Gas Chromatography…
Klíčová slova
recommendation, recommendationintuvo, intuvotop, tophydroinert, hydroinertferrules, ferrulescolumn, columnspecific, specificinlet, inletrecommended, recommendedrough, roughmsds, msdsmanagement, managementliners, linerssepta, septabto