GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
 

Podobná PDF

Toggle
Analysis of polychlorinated p-dibenzodioxins
2016|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of polychlorinated p-dibenzodioxins BPX5 Column Part Number 054114 Phase BPX5 Rate 3 5°C/min to 330°C Column 50 m x 0.22 mm x 0.25 μm Final temperature 330°C, 6 min Initial temperature 80°C, 2 min Detector MS Rate…
Klíčová slova
dibenzodioxins, dibenzodioxinspolychlorinated, polychlorinatedheptachlorodibenzodioxins, heptachlorodibenzodioxinshexachlorodibenzodioxins, hexachlorodibenzodioxinsoctachlorodibenzodioxins, octachlorodibenzodioxinspentachlorodibenzodioxins, pentachlorodibenzodioxinstetrachlorodibenzodioxins, tetrachlorodibenzodioxinsnote, notetemperature, temperatureapplication, applicationfinal, finalcolumn, columninitial, initialpart, partanalysis
APPLICATION NOTE Analysis of polychlorinated dibenzodioxins and furans BPX5 Column part number 054114 Phase BPX5 Rate 3 10°C/min to 320°C Column 50 m x 0.22 mm x 0.25 μm Final temperature 320°C Initial temperature 80°C Detector MS Rate 1 10°C/min…
Klíčová slova
isomers, isomersdibenzodioxins, dibenzodioxinstcdf, tcdftcdd, tcddchromatograms, chromatogramsfurans, furanspolychlorinated, polychlorinatedsingle, singleion, iontemperature, temperaturefinal, finalcolumn, columninitial, initialpart, partcarrier
Analysis of tocopherol isomer mixture
2016|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of tocopherol isomer mixture AN-0172-G © Trajan Scientific Australia Pty Ltd 12/2016 BPX5 Column part number 054144 Phase BPX5 Final temperature 330°C, 5 min Column 15 m x 0.32 mm x 0.25 μm Carrier gas He, 7…
Klíčová slova
tocopherol, tocopherolisomer, isomertemperature, temperatureinjection, injectionfinal, finalmixture, mixturecolumn, columninitial, initialpart, partcarrier, carrierdetector, detectornumber, numbervolume, volumemode, modephase
Analysis of aniline impurities
2016|Trajan Scientific|Aplikace
APPLICATION NOTE Analysis of aniline impurities BPX5 Column part number 054127 Phase BPX5 Rate 2 20°C/min Column 12 m x 0.32 mm x 1.0 μm Final temperature 2 330°C, 10 min Initial temperature 50°C, 1 min Detector FID, 380°C Rate…
Klíčová slova
aniline, anilineimpurities, impuritiescolumn, columninjector, injectorinitial, initialsplit, splitpart, partcarrier, carriercomponents, componentsdetector, detectornumber, numberphase, phasenote, notetemperature, temperaturegas
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.