GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Agilent Technologies
Agilent Technologies
Analytičtí vědci a kliničtí výzkumníci po celém světě spoléhají na Agilent a na to, že jim pomůže splnit i ty nejsložitější požadavky v laboratoři. Naše přístroje, software, služby a spotřební materiál řeší celou škálu potřeb ve Vaší laboratoři.
Tagy
GC/MS
GC/MS/MS
LinkedIn Logo

Methodology Advances in the Sensitive Identification and Quantitation of 1,4-Dioxane in Consumer Products by SPME-EI-GC/MS/MS

ZÁZNAM | Proběhlo St, 31.8.2022
Byla vyvinuta metoda pro vysoce citlivou detekci 1-4-dioxanu na trojitém kvadrupólu Agilent 8890B/7000 GC/QQQ v režimu elektronové ionizace (EI).
Přejít na webinář
Agilent Technologies: Methodology Advances in the Sensitive Identification and Quantitation of 1,4-Dioxane in Consumer Products by SPME-EI-GC/MS/MS
Agilent Technologies: Methodology Advances in the Sensitive Identification and Quantitation of 1,4-Dioxane in Consumer Products by SPME-EI-GC/MS/MS

1,4-Dioxane is an industrial chemical contaminant that is of concern even at trace levels in consumer products. Government jurisdictions are beginning to regulate the amount of 1,4-dioxane allowed in consumer products globally. It has already been banned and deemed unsafe in cosmetics in Canada, and it is a regulated substance in Europe. The allowable concentrations in the United States are expected to vary from state to state, typically at part per billion to low part per million levels.

There have been several methods developed to test for 1,4-dioxane, but none of these methods are adequate to detect 1,4-dioxane in consumer products with complex mixtures and solutions. A method for the high-sensitivity detection of 1-4-Dioxane was developed on the Agilent 8890B/7000 GC/QQQ triple quadrupole in Electron Ionization (EI) mode. The extraction was performed using an Agilent PAL3 autosampler with solid phase microextraction (SPME) tool. The GC was configured with a 30 m DB-8270D column and a 1 m deactivated fused silica column using a purged ultimate union. The advantage of using a tandem quadrupole mass spectrometer is that a selective precursor to product ion transition is generated, minimizing interferences. Analysis time was less than 15 minutes. Calibration curves using 9 levels from 0.1 ng/g (ppb) to 400.0 ng/g (ppb) in multiple reaction monitoring (MRM) Electron Ionization with an R2 value of 0.999. Low detection limits, necessary for these pernicious compounds, were also achieved.

Presenter: Ron Honnold (Application Scientist, Agilent Technologies, Inc.)

Ron Honnold, Ph.D. is an Applications Scientist in the Life Sciences and Applied Markets Group (LSAG) at Agilent Technologies; Santa Clara, CA. Ron is an experienced analytical chemist and mass spectrometrist with more than 30 years of experience using state-of-the-art analytical systems. Currently he is responsible for applications and methods development related to GC-MS products, particularly for single quadrupole (GC/MS), triple quadrupole (GC-MS/MS), and quadrupole time of flight (GC-QTOF). Ron is also a member of the Agilent Cannabis Task Group focusing on pesticides, terpenes, and residual solvents.

Presenter: Simon Jones (GC Applications Engineer/Scientist, Agilent Technologies, Inc.)

Simon Jones has over 23 years of GC experience. For the last 15 years, he has been with Agilent as a GC applications engineer/scientist based out of the GC column manufacturing facility in Folsom California. In his roles he has assisted with application development, troubleshooting chromatographic issues, and assisting with instrument configurations. Prior to joining Agilent in 2005, he worked in an analytical lab for the power industry, developing and optimizing testing methodologies for insulating fluids and materials in transformers.

Agilent Technologies
LinkedIn Logo
 

Mohlo by Vás zajímat

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Aplikace
| 2026 | Shimadzu
Instrumentace
GC/MSD, GC/SQ, HeadSpace
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Aplikace
| 2026 | Shimadzu
Instrumentace
GC/MSD, GC/SQ, HeadSpace
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technické články
| 2026 | Agilent Technologies
Instrumentace
Spotřební materiál, GC kolony
Výrobce
Agilent Technologies
Zaměření
Ostatní

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Aplikace
| 2025 | Shimadzu
Instrumentace
GC
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

Micro GC Analysis of Permanent Gas Impurities in PEM Fuel Cell-Grade Hydrogen

Aplikace
| 2025 | Agilent Technologies
Instrumentace
GC
Výrobce
Agilent Technologies
Zaměření
Průmysl a chemie
Další projekty
LCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.