Dioxins Analysis in the Environment using GC/MS/MS | LabRulez GCMS

Simplifying Persistent Issues with Dioxins Analysis in the Environment using GC/MS/MS

St, 14.9.2022, 19:00 (CEST)
Tato práce ukazuje, že systém Agilent triple quadrupole GC/MS může dosáhnout citlivosti požadované pro splnění a překročení požadavků pro analýzu PCDD/PCDF na všech úrovních koncentrace.
Agilent Technologies: Simplifying Persistent Issues with Dioxins Analysis in the Environment using GC/MS/MS

Agilent Technologies: Simplifying Persistent Issues with Dioxins Analysis in the Environment using GC/MS/MS

U.S. EPA Method 1613B has been one of the primary methods used in the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in wastewater, soils, sludges, and other matrices. These compounds have more than 200 congeners, and seventeen of them are highly toxic and of interest in trace analysis.

Historically, these analyses have been performed using magnetic sector high resolution GC/MS. In 2021, the U.S. EPA approved an alternate testing protocol (ATP) that accepts GC/TQ as an equivalent technology for the analysis of dioxins in environmental samples.

This work shows the Agilent triple quadrupole GC/MS system can achieve the sensitivity required to meet and exceed guidance for the analysis of PCDD/PCDFs at all concentration levels.

Presenter: Joel Ferrer (Product Manager - Agilent QQQ GC/MS, Agilent Technologies, Inc.)

Joel Ferrer is the Product Manager for the Agilent Triple Quadrupole GC/MS portfolio. He obtained his B.S. in Biomedical Sciences at Texas A&M University where he gained experience on Agilent LC/MS and GC/MS instrumentation performing metabolomics research in the Department of Chemistry. Joel later earned his MBA from the University of Houston with a focus in Product Management and Marketing Analytics. He’s been with Agilent for over 5 years and in his current product management role since June 2020.

Agilent Technologies
 

Mohlo by Vás zajímat

Analysis of Heavy Fuel Oil Using Multi-Mode Ionization

Aplikace
| 2022 | LECO
Instrumentace
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Výrobce
LECO
Zaměření
Průmysl a chemie

Trace level quantitation of Ethylene Oxide (EtO) and 2-Chloroethanol (2-CE) in sesame seeds by using various GCMS/MS techniques with their own merits and demerits

Aplikace
| 2022 | Shimadzu
Instrumentace
GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

Five Keys to Unlock Maximum Performance in the Analysis of Over 200 Pesticides in Challenging Food Matrices by GC/MS/MS

Aplikace
| 2022 | Agilent Technologies
Instrumentace
GC/MSD, GC/MS/MS, GC/QQQ
Výrobce
Agilent Technologies
Zaměření
Potraviny a zemědělství

Comprehensive analysis of electrolyte solutions for lithium- ion batteries using gas chromatography-mass spectrometry

Aplikace
| 2022 | Thermo Fischer Scientific
Instrumentace
GC/MSD, GC/SQ
Výrobce
Thermo Fischer Scientific
Zaměření
Průmysl a chemie

Multi-residue analysis of pesticides in edible oils by triple quadrupole GC-MS

Aplikace
| 2022 | Thermo Fischer Scientific
Instrumentace
GC/MSD, GC/MS/MS, GC/QQQ
Výrobce
Thermo Fischer Scientific
Zaměření
Potraviny a zemědělství
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití

LabRulez s.r.o. Všechna práva vyhrazena.