GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Separation Science
Separation Science
Separation Science je přední online zdroj metod, aplikací, řešení problémů a školení v chromatografii a hmotnostní spektrometrii.
Tagy
GC/MS
GC/MS/MS
LC/MS
LC/MS/MS
LinkedIn Logo

Solving the Challenges and Workflow Dilemma of High-throughput Multi-residue Pesticide Screening Program in a Quality Control Environment

ZÁZNAM | Proběhlo Út, 10.12.2019
Separation Science Vám ve spolupráci s Thermo Fisher Scientific přináší webinář, popisující optimalizaci pracovních postupů pro analýzu pesticidů v potravinách technikami LC-MS a GC-MS.
Přejít na webinář
Pixabay/Bruno Glätsch: Solving the Challenges and Workflow Dilemma of High-throughput Multi-residue Pesticide Screening Program in a Quality Control Environment
Pixabay/Bruno Glätsch: Solving the Challenges and Workflow Dilemma of High-throughput Multi-residue Pesticide Screening Program in a Quality Control Environment

The widespread use of pesticides and the societal pressure to manufacture the purest, safest natural products mandates development of methods for precise determination of pesticide residues in botanical ingredients. Pesticide residue analysis of plant based dry ingredients used in dietary supplements is among the most difficult to perform due to complexity of the matrices.

Furthermore, implementation of a multi-residue pesticide screening program in a quality control environment can be quite difficult and time consuming. Therefore, many companies turn to specialized contract laboratories to perform such comprehensive testing. Although third party testing is commonly utilized, the in-house pesticide residue screen provides an additional layer of quality control and further ensures the safety of manufactured products.

Optimization of the critical parts of the process such as sample preparation procedure, analysis of the samples and data processing and reporting guarantees a robust and a productive workflow. At NOW Foods, two analytical platforms, GC-MS/MS and LC-MS/MS were utilized in the development of a high throughput workflow to screen a total of 500 pesticide residues in botanical matrices. Sample preparation was optimized for groups of botanical matrices and targeted towards matrix mitigation. The robustness of both platforms was evaluated over time when analyzing matrix heavy samples.

The GC-MS/MS analysis was performed on a TSQ9000 and the compound separation was optimized on a TG-5SILMS column. The LC-MS/MS analysis was performed on a TSQ Altis paired with a Vanquish LC. The chromatographic separation of the 254 compounds was achieved in 20 min. Data processing and reporting was streamlined by utilizing the Chromeleon software across both platforms.

The optimized workflow allows for a high throughput analysis of samples in a regulated quality control environment.

By attending this webinar you will learn about:
  • optimization of LC-MS and GC-MS workflows for pesticide analysis in food
  • techniques for extracting difficult food matrices
  • the use of Chromeleon software to streamline sample reporting

Presenter: Katie Banaszewski (NOW Foods)

Katie Banaszewski is a Method Development Supervisor at NOW Foods, where she leads the development and validation of analytical methods. Prior to joining NOW Foods she worked at the Institute for Food Safety and Health and Mars Snackfood US. Katie specializes in mass spectrometry applications and residue analysis, and leads the development and implementation of a routine pesticide residue monitoring program at NOW Foods.

Separation Science
LinkedIn Logo
 

Mohlo by Vás zajímat

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Aplikace
| 2026 | Shimadzu
Instrumentace
GC/MSD, GC/SQ, HeadSpace
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Aplikace
| 2026 | Shimadzu
Instrumentace
GC/MSD, GC/SQ, HeadSpace
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technické články
| 2026 | Agilent Technologies
Instrumentace
Spotřební materiál, GC kolony
Výrobce
Agilent Technologies
Zaměření
Ostatní

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Aplikace
| 2025 | Shimadzu
Instrumentace
GC
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

Micro GC Analysis of Permanent Gas Impurities in PEM Fuel Cell-Grade Hydrogen

Aplikace
| 2025 | Agilent Technologies
Instrumentace
GC
Výrobce
Agilent Technologies
Zaměření
Průmysl a chemie
Další projekty
LCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.