Importance of Liner Selection in Aqueous Solution Analysis
Technické články | 2022 | ShimadzuInstrumentace
GC, Spotřební materiál
ZaměřeníVýrobceShimadzu
Klíčová slovaethanol, solution, liner, aqueous, spirit, evaluation, special, alcohol, distilled, japanese, beer, sanitizer, isopropyl, concentration, tailing, sample, standard, analysis, tcd, injection, solvent, area, wool, controller, gel, shapes, measurement, ratio, suitability, peak, vaporizes, syringe, solutions, min, gas, news, fid, were, irregular, water, detector, liquor, column, acetonitrile, differs, occurrence, rsd, vaporization, carrier, application
Podobná PDF
Hand Sanitizer Analysis: Application Notebook
2020|Shimadzu|Příručky
Hand Sanitizer Analysis: Application Notebook Solutions for Hand Sanitizer Analysis Application Notebook The Covid-19 pandemic has led to an increase in usage of hand sanitizers as emphasis on disease prevention focuses on cleanliness and personal hygiene. Ensuring the purity and…
Klíčová slova
ethanol, ethanolsanitizer, sanitizerhand, handsanitizers, sanitizersanhydrous, anhydrousacetaldehyde, acetaldehydefail, failsolution, solutionalcohol, alcoholjudgment, judgmentpass, passusp, uspstandard, standarddisinfection, disinfectionacetal
Analysis of Ethanol in Liquors Using Nexis™ GC-2030
2019|Shimadzu|Aplikace
LAAN-A-GC-E080 Application News Gas Chromatography Analysis of Ethanol in Liquors Using Nexis™ GC-2030 No. G315 The Japanese National Tax Agency (NTA) prescribes analytical methods for ethanol in liquors, which are official methods. Various analytical methods are included, and the prescribed…
Klíčová slova
value, valueconcentration, concentrationanalysis, analysisethanol, ethanolliqueur, liqueurexpelling, expellingjapanese, japaneseisopropyl, isopropylsake, sakealcohol, alcoholstandard, standardbeer, beergas, gasninth, ninthratio
Hand Sanitizer Analysis Using the Agilent 8860 GC Configured with a Flame Ionization Detector
2020|Agilent Technologies|Aplikace
Application Note Hand Sanitizer Analysis Using the Agilent 8860 GC Configured with a Flame Ionization Detector Author Jie Zhang Agilent Technologies, Inc. Abstract This application note describes the analysis of ethanol- and isopropanol‑based hand sanitizer. The Agilent J&W DB-WAX column…
Klíčová slova
ethanol, ethanolsanitizer, sanitizeripa, ipaglycerin, glycerinalcohol, alcoholalcohols, alcoholshand, handpropanol, propanolquantitation, quantitationvol, volisopropanol, isopropanolcalibration, calibrationresponse, responseacn, acnmethanol
Alcohol Determination of Sanitizer Gel in accordance with USP<611>
2020|Shimadzu|Aplikace
Application News No. G333 Gas Chromatography Alcohol Determination of Sanitizer Gel in accordance with USP<611> United States Pharmacopeia (USP) General Chapters <611> ALCOHOL DETERMINATION stipulates two analytical methods for quantitating ethanol: one with distillation and the other by gas chromatography.…
Klíčová slova
solution, solutionethanol, ethanolsanitizer, sanitizerratio, ratiostandard, standardtrademark, trademarkalcohol, alcoholdilute, dilutegel, gelusp, usparea, areasplit, splitchromatogram, chromatogramsample, sampletailing