Analysis of Volatile Organic Compounds in Soil Sample by EPA Method 8260 using CDS 7000C Dynamic Headspace Module
Aplikace | | CDS AnalyticalInstrumentace
GC/MSD, Purge and Trap, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceShimadzu, CDS Analytical
Klíčová slovapurge, temperature, surr, desorb, rrf, internal, bake, trap, rsd, trichloromonofluoromethane, chloride, tetrachloride, trichloromethane, flow, standard, dibromofluoromethane, carryover, dry, tetrachloroethylene, calibration, external, dichlorodifluoromethane, wet, stirrer, module, bromochlorotrichloromethane, dibromochlorostyrene, eightstandard, methylenefluorochloride, mixedfrom, standardcalibration, theeight, xang, carbon, thetime, sensor, figurefigure, ethylbenzene, warmup, mdl, xiaohui, replicate, figure, benzene, ready, inert, headspace, time, mfc, dynamic
Podobná PDF
#191 EPA Method 8260C Using CDS Analytical 7000C Purge and Trap with a PAL System Application Note Environmental EPA Method 8260C Using CDS Analytical 7000C Purge and Trap with P Abstract System CDS 7000C Purge and Trap Concentrator coupled to…
Klíčová slova
rrf, rrftrap, trapdesorb, desorbpurge, purgebake, bakertc, rtctemperature, temperaturesupelco, supelcosurrogate, surrogatestandard, standardrail, railinternal, internalconcentrator, concentratortype, typecalibration
Reducing the helium consumption for analysis of VOCs in accordance with EPA Method 8260D without compromising performance using HeSaver-H2 Safer technology
2023|Thermo Fisher Scientific|Aplikace
Application note | 002337 Environmental Reducing the helium consumption for analysis of VOCs in accordance with EPA Method 8260D without compromising performance using HeSaver-H2Safer technology Goal Authors Amy Nutter , Terry Jeffers , Adam Ladak , To describe the use…
Klíčová slova
min, mintert, tertacetate, acetatequan, quanether, etheristd, istdbutyl, butylbutylbenzene, butylbenzenebake, bakeprecision, precisionpurge, purgemethyl, methylsweep, sweeptime, timeethyl
US EPA Method 524.2: Successful Measurement of Purgeable Organic Compounds in Drinking Water by Agilent 8860/5977B GC/MSD
2019|Agilent Technologies|Aplikace
Application Note Environmental US EPA Method 524.2: Successful Measurement of Purgeable Organic Compounds in Drinking Water by Agilent 8860/5977B GC/MSD Authors Bruce D. Quimby and Anastasia A. Andrianova Agilent Technologies, Inc. Abstract An Agilent 8860/5977B GC/MSD system coupled with a…
Klíčová slova
rrf, rrfistd, istdtrichloromonofluoromethane, trichloromonofluoromethanetribromomethane, tribromomethanebfb, bfbchloride, chlorideethyl, ethylbutylbenzene, butylbenzenemethyl, methylmethacrylate, methacrylateaquatek, aquatektetrachloroethylene, tetrachloroethylenesurr, surrtert, tertbake
Uninterrupted analysis of VOCs according to U.S. EPA Method 8260C using purge and trap and single quadrupole GC-MS technology
2022|Thermo Fisher Scientific|Aplikace
Application note | 001018 Environmental analysis Uninterrupted analysis of VOCs according to U.S. EPA Method 8260C using purge and trap and single quadrupole GC-MS technology Authors Goal Adam Ladak , Terry Jeffers , and Demonstration of an analytical method that…
Klíčová slova
rrf, rrfpurge, purgebake, bakesweep, sweepacetate, acetatetert, tertether, etherprecision, precisioncalibration, calibrationtime, timerinse, rinsemid, midcompound, compoundbutylbenzene, butylbenzenevariable