Stir Bar Sorptive Extraction (TwisterTM) RTL-CGC-MS. A Versatile Method to Monitor more than 400 Pesticides in Different Matrices (Water, Beverages, Fruits, Vegetables, Baby Food)
Aplikace | 2003 | Research Institute for ChromatographyInstrumentace
GC/MSD, Příprava vzorků, GC/SQ
ZaměřeníŽivotní prostředí, Potraviny a zemědělství
VýrobceAgilent Technologies, GERSTEL
Klíčová slovapesticides, isomer, dinocap, sbse, methyl, rtl, screener, ethyl, cpd, endosulfan, cyfluthrin, cypermethrin, permethrin, allate, chlorthiophos, thermally, cas, procymidone, dinoterb, flurochloridone, difenoconazol, bhc, bioallethrin, heptachlor, dodemorph, flamprop, endrin, methoprene, bromoxynil, bromobutide, pyrifenox, flucythrinate, phenothrin, cis, fluvalinate, extracted, dinoseb, tau, tetramethrin, iii, tolylfluanid, leptophos, bitertanol, sensitive, tdu, bromophos, benalaxyl, desorption, name, result
Podobná PDF
Increasing productivity in pesticide residues analysis by GC-MS/MS with on-line automated micro solid phase extraction (μSPE) clean-up
2023|Thermo Fisher Scientific|Aplikace
Technical note | 002569 Food safety Increasing productivity in pesticide residues analysis by GC-MS/MS with on-line automated micro solid phase extraction (µSPE) clean-up Authors Goal Lukasz Rajski1, Moira Zanaboni2, The aims of this study were to evaluate the overall performance,…
Klíčová slova
methyl, methylethyl, ethylrsd, rsdbromophos, bromophosrecovery, recoveryµspe, µspebromfenvinphos, bromfenvinphosendrin, endrinendosulfan, endosulfannonachlor, nonachloronion, onionclean, cleanpirimiphos, pirimiphosmass, massazinphos
A sensitive and robust analytical solution for pesticide residues analysis in apple using GC-(AEI)-MS/MS
2019|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE 65609 A sensitive and robust analytical solution for pesticide residues analysis in apple using GC-(AEI)-MS/MS Authors: Subodh Kumar Budakoti, Sarvendra Pratap Singh, and Dasharath Oulkar, Customer Solution Center, Thermo Fisher Scientific, Ghaziabad, India Keywords: Advanced electron ionization (AEI),…
Klíčová slova
loq, loqrec, recpermethrin, permethrintrans, transrsd, rsdcis, cismethyl, methylethyl, ethylmms, mmsinjections, injectionsion, ionquantitation, quantitationbromophos, bromophosarea, areaapple
Determination of 277 Pesticides at Trace Levels by GC–TOFMS
2007|Agilent Technologies|Aplikace
® Determination of 277 Pesticides at Trace Levels by GC–TOFMS Sjaak de Koning, Monika Gumpendobler • LECO Instrumente, Mönchengladbach, Germany Key Words: TOFMS, Pesticides, Trace Analysis, Quantification, Food 3.5e+006 3e+006 2.5e+006 2e+006 1.5e+006 1e+006 Time (s) 200 400 For all…
Klíčová slova
ethyl, ethyltrans, transcis, cisdemeton, demetonhch, hchpropiconazole, propiconazolemethyl, methylanthraquinone, anthraquinoneparathion, parathionquant, quantendosulfan, endosulfanchlorpyrifos, chlorpyrifoscyanazine, cyanazinecresol, cresolabsolute
Analysis of Semivolatile Compounds in Water
2023|Agilent Technologies|Aplikace
Application Note Environmental Analysis of Semivolatile Compounds in Water Low-density liquid-liquid microextraction (LDME) with the Agilent 7010 Triple Quadrupole GC/MS Authors Estefanía Lasheras Fabo CNTA, San Adrian, Spain Carlos Bueno Berezo Madrid, Spain Jose Juan Rivero Agilent Technologies, Inc. Abstract…
Klíčová slova
ldme, ldmerelative, relativeheptachlor, heptachloraccuracy, accuracybenzo, benzowater, wateracquisition, acquisitionabundance, abundancehexaclorociclohexano, hexaclorociclohexanoendosulfan, endosulfanepoxide, epoxidemethyl, methylsvocs, svocsproficiency, proficiencymin