Swafer Micro-Channel Flow Technology – Automated Inlet Selection for GC/MS
Technické články | 2012 | PerkinElmerInstrumentace
GC/MSD, HeadSpace, GC/SQ
VýrobcePerkinElmer
Klíčová slovaheadspace, injector, swafer, capillary, switching, automated, channel, technology, clarus, carrier, techniques, gas, injection, liquid, restrictor, perkinelmer, timed, specialized, pressure, remediate, events, flow, fuel, disastrous, vocs, between, inlet, jet, user, utilizing, switchover, switch, decides, set, heartcutting, trickle, column, greg, temp, hardware, entire, micro, johnson, than, another, setting, system, forth, revealing, either
Podobná PDF
Characterization of Hop Aroma Using GC/MS, Headspace Trap and Olfactory Port
2013|PerkinElmer|Aplikace
A P P L I C AT I O N N O T EGas Chromatography/Mass SpectrometryAuthor:Andrew TiplerPerkinElmer, Inc.Shelton, CTCharacterization ofHop Aroma UsingGC/MS, HeadspaceTrap and Olfactory PortIntroductionHops are a critical ingredient inbeer. They provide an importantbalance to the malt in the...
Klíčová slova
smell, smellhops, hopsaroma, aromaolfactory, olfactorytrap, trapscan, scantic, ticsweet, sweetvery, veryalmost, almostswafer, swaferheadspace, headspacevial, vialsour, soursnfr
The Determination of C1 to C5 Hydrocarbons in Gas Streams Using the PerkinElmer Swafer Technology
2011|PerkinElmer|Aplikace
a p p l i c at i o n N o t eGas ChromatographyAuthor:A. TiplerPerkinElmer, Inc.Shelton, CT 06484 USAThe Determination ofC1 to C5 Hydrocarbonsin Gas Streams Usingthe PerkinElmerSwafer TechnologyIntroductionThe determination of light hydrocarbons in refinery andother gases is typically...
Klíčová slova
precolumn, precolumnbackflushed, backflushedrestrictor, restrictoreffluent, effluentinjector, injectorbackflush, backflushdetector, detectorgas, gasbackflushing, backflushingtimed, timedcolumn, columnswafer, swafersplit, splitthrough, throughreturned
Determination of Low-Level Oxygenated Compounds in Gasoline Using the Clarus 680 GC with S-Swafer Micro-Channel Flow Technology
2010|PerkinElmer|Aplikace
a p p l i c at i o n N o t eGas ChromatographyAuthorAndrew TiplerPerkinElmer, Inc.Shelton, CT 06484 USADetermination ofLow-Level OxygenatedCompounds in GasolineUsing the Clarus 680 GCwith S-Swafer MicroChannel Flow TechnologyIntroductionThe existing ASTM® D4815 method is designed to monitoroxygenated...
Klíčová slova
swafer, swafertert, tertoxygenated, oxygenatedgasoline, gasolinerestrictor, restrictorchromatographed, chromatographedprecolumn, precolumnbutanol, butanolcompounds, compoundsbutylether, butyletherether, ethercolumn, columnlowox, lowoxpentanol, pentanoldipe
Clarus Gas Chromatographs - Clarus 680/580/480
2015|PerkinElmer|Brožury a specifikace
NATURALLYBETTERCHROMATOGRAPHYSOLUTIONSClarus Gas ChromatographsCl ar us 680/580 /480CLARUS DELIVERSPOWER AND PERFORMANCEAT EVERY LEVELThe Clarus GC Family – Performance you can relyon from the leader in Gas Chromatography andsample-handling solutionsWith more than 50 years’ experience in Gas Chromatography (GC), the PerkinElmer® familyof...
Klíčová slova
clarus, clarusperkinelmer, perkinelmerturbomatrix, turbomatrixswafer, swaferprogrammable, programmableinjectors, injectorsheadspace, headspacethermal, thermalflexibility, flexibilityfastest, fastestchannel, channelyour, yourconfigurations, configurationsdesorbers, desorbersperformance