Comparison of Screening Method (Py-GC/MS) and Quantitative Method (Solvent Extraction–GC/MS) for Phthalate Esters Analysis
Aplikace | 2016 | ShimadzuInstrumentace
GC/MSD, Pyrolýza, GC/SQ
ZaměřeníMateriálová analýza
VýrobceShimadzu, Frontier Lab
Klíčová slovaphthalate, screener, extraction, dehp, esters, scan, solvent, sim, bbp, soxhlet, event, mode, dbp, dissolution, method, using, fasst, amended, quantitative, didp, rsd, dinp, standard, thermal, screening, precipitation, ester, clarifies, ratio, concentrations, compared, range, preparation, analytical, punching, considered, equivalent, criteria, terms, tabular, mass, standards, traction, repeatability, were, welfare, measurements, solution, markedly, without
Podobná PDF
Analysis of Phthalate Esters Using the Py-Screener (1)
2015|Shimadzu|Aplikace
LAAN-J-MS-E110 GC-MS Gas Chromatograph Mass Spectrometer Analysis of Phthalate Esters Using the Py-Screener (1) 110 In the RoHS directive (directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment), four phthalate esters: diisobutyl phthalate…
Klíčová slova
phthalate, phthalatedidp, didpesters, estersdibp, dibpscreener, screenerdinp, dinpbbp, bbpdehp, dehpdbp, dbpscan, scandirective, directiveester, esterevent, eventpyrolizer, pyrolizerpuncher
A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters and Brominated Flame Retardants
2015|Shimadzu|Aplikace
No. SSI-GCMS-1504 Gas Chromatograph Mass Spectrometer No. GCMS-1504 A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters and Brominated Flame Retardants ■ Introduction The Restriction of Hazardous Substances (RoHS) Directive controls six hazardous substances commonly used in electronic and electrical…
Klíčová slova
phthalate, phthalatescreener, screenersim, simpackage, packagednop, dnopconveyor, conveyorlabsolution, labsolutiondidp, didpdinp, dinpdehp, dehpdbp, dbpqaqc, qaqchimadzu, himadzuhbcdd, hbcddfurnace
A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters and Brominated Flame Retardants
2016|Shimadzu|Postery
PO-CON1616E A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters and Brominated Flame Retardants Pittcon 2016 2290-12 Nicole Lock, Laura Chambers, Andy Sandy, Ian Duffy Shimadzu Scientific Instruments, Columbia, MD, USA A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters…
Klíčová slova
phthalate, phthalateretardants, retardantsbrominated, brominatedpyrolysis, pyrolysisesters, estersflame, flamedidp, didpdinp, dinpscreening, screeningconveyor, conveyorlabsolution, labsolutionscreener, screenersim, simpolymer, polymerppm
Screening Analysis of Phthalate Esters and Qualitative Analysis of Other Additives in Medical Supplies Using the Py-GC/MS Screening System
2018|Shimadzu|Aplikace
LAAN-J-MS-E135 GC-MS Gas Chromatograph Mass Spectrometer Screening Analysis of Phthalate Esters and Qualitative Analysis of Other Additives in Medical Supplies Using the Py-GC/MS Screening System 135 Although phthalate esters are used as plasticizing agents in plastics, there are concerns over…
Klíčová slova
palmitic, palmiticlubricant, lubricantintravenous, intravenousdehp, dehpester, esteracid, acidrsd, rsdtransfusion, transfusiontotm, totmconcentration, concentrationplasticizer, plasticizerstearic, stearicantioxidant, antioxidantmethyl, methylmedical