Rapid and cost-effective determination of Class 3 residual solvents in pharmaceutical products by HS-GC with hydrogen as carrier gas
Aplikace | 2023 | Thermo Fisher ScientificInstrumentace
GC, GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ
ZaměřeníFarmaceutická analýza
VýrobceThermo Fisher Scientific
Klíčová slovaacetate, min, solvents, ethyl, residual, anisole, response, butylmethyl, solution, fid, time, mdl, ether, acetone, peak, chromatographic, headspace, loop, formate, sample, vial, kpa, temperature, ethanol, processes, cds, column, mode, stated, isobutyl, alternative, rsd, propyl, heptane, pentane, incubation, pressure, accepted, volatile, isopropyl, deconvoluted, gas, tert, separation, achieved, static, optimized, methylisobutylketone, usp, thermo
Podobná PDF
Analysis of USP <467> Residual Solvents of Class 1, Class 2, and Class 3 using the Agilent 8890 GC/ FID /5977B MSD System
2019|Agilent Technologies|Aplikace
Application Note Pharma & Biopharma Analysis of USP <467> Residual Solvents of Class 1, Class 2, and Class 3 using the Agilent 8890 GC/ FID /5977B MSD System Authors Youjuan Zhang, Shun Na Agilent Technologies (Shanghai) Co. Ltd. Shanghai 200131…
Klíčová slova
msd, msdacetate, acetatefid, fiddmso, dmsoheadspace, headspacebutylmethyl, butylmethylformic, formicacid, acidethyl, ethylglycol, glycolcft, cftvial, vialloop, loopacetic, aceticethylene
Novel Residual Solvents Analysis of Cannabinoid Products with the Agilent Headspace-GC/MS System
2020|Agilent Technologies|Aplikace
Application Note Cannabis Testing Novel Residual Solvents Analysis of Cannabinoid Products with the Agilent Headspace-GC/MS System Authors Terry Harper1, Jeffery S. Hollis1, Eric Fausett1, and Anthony Macherone1,2 1 Agilent Technologies, Inc. 2 Johns Hopkins University School of Medicine Abstract Residual…
Klíčová slova
true, truelinear, linearxylene, xylenelod, lodoxide, oxidecalibrator, calibratorethylene, ethyleneethyl, ethylresidual, residualmdl, mdltft, tftsolvents, solventscannabis, cannabiscannabinoid, cannabinoidbutane
Routine-grade performance of a new static headspace autosampler for the analysis of residual solvents according to USP <467> method
2018|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE 10676 Routine-grade performance of a new static headspace autosampler for the analysis of residual solvents according to USP <467> method Authors Giulia Riccardino1, Paolo Magni2, Stefano Pelagatti2, Manuela Bergna2, Davide Bressanello2, and Cristian Cojocariu1 Thermo Fisher Scientific, Runcorn,…
Klíčová slova
xylene, xyleneresidual, residualsolvents, solventstetralin, tetralinprocedure, procedurechlorobenzene, chlorobenzenepharmaceutical, pharmaceuticalaccording, accordingaspirin, aspirinmethycyclohexane, methycyclohexanetoluene, toluenenitromethane, nitromethanechloroform, chloroformpyridine, pyridinechromeleon
Analysis of Organic Volatile Impurities in Drug Products and Drug Substances
2021|Agilent Technologies|Aplikace
Application Note Biopharma Analysis of Organic Volatile Impurities in Drug Products and Drug Substances Authors Srikanth Ghanta Honour Labs Ltd. Bonthapally, India Soma Dasgupta Agilent Technologies, Inc. Bangalore, India Abstract This application note highlights a solution for the determination of…
Klíčová slova
ether, etherisopropyl, isopropylacetate, acetatemethylmorpholine, methylmorpholinemethyl, methylketone, ketoneethyl, ethylsolvent, solventmesityl, mesitylheadspace, headspacesolvents, solventsacetaldehyde, acetaldehydepeak, peakarea, areadimethylformamide