GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

New workflow for contaminants screening in strawberries using high-resolution GC/Q-TOF and expanded accurate mass library of pesticides and environmental pollutants

 

Podobná PDF

Toggle
Application Note Food Testing & Agriculture Contaminants Screening Using High‑Resolution GC/Q-TOF and an Expanded Accurate Mass Library of Pesticides and Environmental Pollutants Authors Sofia Nieto, Anastasia Andrianova, Jessica Westland, Kai Chen, and Bruce Quimby Agilent Technologies, Inc. Abstract The use…
Klíčová slova
tof, tofscreening, screeningpesticides, pesticidesloq, loqmsd, msdaccurate, accuratesuspect, suspectfalse, falsestrawberry, strawberrysnb, snbhsd, hsdrtp, rtpcontaminants, contaminantsworkflow, workflowlibrary
Application Note Food Testing GC/MSD Pesticide Screening in Strawberries at Tolerance Levels Using Library Searching of Deconvoluted Spectra Authors Anastasia A. Andrianova, Bruce D. Quimby, and Jessica L. Westland Agilent Technologies, Inc. Abstract The Agilent 8890 GC system and Agilent…
Klíčová slova
pesticides, pesticidesrtl, rtldeconvoluted, deconvolutedfludioxonil, fludioxonillibrary, librarypesticide, pesticideunknowns, unknownshits, hitspsd, psdinlet, inletsemistandard, semistandardcounts, countsagilent, agilentlms, lmsstrawberries
Application Note Environmental Analysis of Wastewater Effluent Samples to Identify Toxic Chemicals Using the High-Resolution Agilent 7250 GC/Q-TOF Authors Sofia Nieto and Kai Chen Agilent Technologies, Inc. Thomas Young Department of Civil and Environmental Engineering, University of California Davis, CA,…
Klíčová slova
wastewater, wastewaterscreening, screeningnci, nciscore, scoreeffluent, effluentmatch, matchtof, toflibrary, librarynontargeted, nontargetedcompounds, compoundssuspect, suspectresponse, responsetentative, tentativeidentify, identifymass
Application Note Food Testing Pesticide Screening in Strawberries Using the Agilent 8860 GC with the Agilent 5977B GC/MSD and SureTarget Deconvolution Authors Anastasia A. Andrianova, Bruce D. Quimby, and Jessica L. Westland Agilent Technologies, Inc. Abstract The Agilent 8860 GC…
Klíčová slova
pesticides, pesticidesdeconvoluted, deconvolutedrtl, rtllms, lmsfenhexamid, fenhexamidlibrary, librarysarin, sarinspectrum, spectrumunknowns, unknownspesticide, pesticidecounts, countssplitless, splitlessmasshunter, masshunterinlet, inletsemistandard
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.