Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler
Aplikace | 2009 | Tekmar TeledyneInstrumentace
GC/MSD, Purge and Trap, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceAgilent Technologies, Tekmar Teledyne
Klíčová slovatemp, bake, purge, rinse, desorb, condensate, sweep, soil, flow, time, water, needle, prepurge, ccv, sparge, spcc, dry, preheat, dev, methanol, mdl, acetate, standby, volume, off, vessel, atomx, heater, spike, variable, drain, sample, presweep, start, valve, methyl, ether, rinses, calibration, value, chloride, amyl, rsd, butylbenzene, glass, mount, methacrylate, level, parameters, surrogate
Podobná PDF
US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS
2017|Agilent Technologies|Aplikace
US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Application Note Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e |1 Abstract US EPA Method 8260 in conjunction with Methods 5030 and…
Klíčová slova
temp, temppurge, purgebake, bakeppb, ppbdesorb, desorbrinse, rinseacetate, acetateaverage, averagesweep, sweeptert, tertatomx, atomxrsd, rsdether, etherxyz, xyzmcs
US EPA Method 8260 Using the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS System with an ExtractaBrite Source
2020|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1801 P+T VOC ENV US EPA Method 8260 Using the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS System with an ExtractaBrite Source Amy Nutter, Applications Chemist; Teledyne Tekmar P…
Klíčová slova
temp, temppurge, purgebake, bakerinse, rinseacetate, acetatedesorb, desorbsweep, sweepprecision, precisiontert, terttime, timedemonstration, demonstrationether, ethercondensate, condensatevariable, variablemdl
US EPA Method 8260 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with Advanced Electron Ionization (AEI) Source
2019|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1908 P+T VOC ENV US EPA Method 8260 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with Advanced Electron Ionization (AEI) Source Amy Nutter, Applications Chemist; Teledyne…
Klíčová slova
temp, temppurge, purgebake, bakedesorb, desorbrinse, rinsesweep, sweeptert, tertacetate, acetateether, ethertime, timecondensate, condensateaverage, averagevariable, variablebutyl, butylmethyl
Validation of Volatile Organic Compound by USEPA Method 8260C
2011|Agilent Technologies|Aplikace
Validation of Volatile Organic Compound by USEPA Method 8260C Application Note Abstract In order to determine the concentration of volatile organic compounds (VOCs) in water and soil matrices 1 2 3 the USEPA developed Method 8260C in conjunction with preparative…
Klíčová slova
temp, tempbake, bakedesorbs, desorbspurge, purgeusepa, useparinse, rinsecondensate, condensatesweep, sweepvolatile, volatiletime, timevalidation, validationflow, flowcompound, compoundneedle, needleprepurge