Determination of SVOCs in water samples using the Bruker μDROP™ method for the EVOQ™ GC-TQ MS/MS system
Aplikace | 2018 | BrukerInstrumentace
GC/MSD, GC/MS/MS, Příprava vzorků, GC/QQQ
ZaměřeníŽivotní prostředí
VýrobceBruker
Klíčová slovaµdrop, bruker, water, hch, eqs, endosulfan, intensity, ppt, heptachlor, working, benzo, retention, quality, min, microextraction, method, evoq, fluoranthene, low, compounds, river, each, microdroplets, extraction, mrl, concentration, study, blank, time, epoxide, area, inland, svocs, signal, surface, set, mdl, substances, matrices, calibration, cibutryn, aldrin, prepared, standards, chlorphenvinfos, slope, criteria, sample, linearity, pyrene
Podobná PDF
Analysis of Semivolatile Compounds in Water
2023|Agilent Technologies|Aplikace
Application Note Environmental Analysis of Semivolatile Compounds in Water Low-density liquid-liquid microextraction (LDME) with the Agilent 7010 Triple Quadrupole GC/MS Authors Estefanía Lasheras Fabo CNTA, San Adrian, Spain Carlos Bueno Berezo Madrid, Spain Jose Juan Rivero Agilent Technologies, Inc. Abstract…
Klíčová slova
ldme, ldmerelative, relativeheptachlor, heptachloraccuracy, accuracybenzo, benzowater, wateracquisition, acquisitionabundance, abundancehexaclorociclohexano, hexaclorociclohexanoendosulfan, endosulfanepoxide, epoxidemethyl, methylsvocs, svocsproficiency, proficiencymin
Highly Sensitive Determination of Contaminants in Surface Water in the Context of the EU Water Framework Directive using Stir Bar Sorptive Extraction (SBSE) and GC-MS/MS
2018|Agilent Technologies|Aplikace
GERSTEL Application Note No. 196, 2018 Highly Sensitive Determination of Contaminants in Surface Water in the Context of the EU Water Framework Directive using Stir Bar Sorptive Extraction (SBSE) and GC-MS/MS Oliver Lerch1, Jasmin Zboron1, Ken Brady2, Juan-Luis Aybar3 1.…
Klíčová slova
loq, loqwater, waterriver, rivertap, taphexachlorocyclohexane, hexachlorocyclohexanewest, westmineral, mineralgermany, germanymid, midinland, inlandwfd, wfdbenzo, benzosurface, surfacetwister, twisterrespective
Evaluation of Tandem Mass Spectrometry for the Analysis of Environmental Samples
2010|Bruker|Aplikace
Chemical Analysis Application Note # CA-270125 Evaluation of Tandem Mass Spectrometry for the Analysis of Environmental Samples Introduction Calibration solution and spiked sample U.S. Environmental Protection Agency (EPA) Method 525.2, “Determination of Organic Compounds in Drinking Water by Liquid –…
Klíčová slova
bhc, bhcbenzo, benzosim, simphthalate, phthalatemode, modechlordane, chlordanechlorprophan, chlorprophansolvent, solventheptachlor, heptachlortriflualin, triflualinendosulfan, endosulfanrsd, rsdchlorneb, chlornebheptachlorobiphenyl, heptachlorobiphenylmatrix
Surface water screening for chloroalkane contamination via Bruker μDROP and GC-MS/MS
2021|Bruker|Aplikace
Surface water screening for chloroalkane contamination via Bruker µDROP and GC-MS/MS Environmental protection by rapid target extraction for sensitive and specific determination of chloroalkane pollutants using the EVOQ GC-Triple Quadrupole MS/MS system Abstract Modern measures to protect surface waters against…
Klíčová slova
µdrop, µdropchloroalkanes, chloroalkanesbruker, brukerevoq, evoqeqs, eqschloroalkane, chloroalkanesccps, sccpsppt, pptwater, watersurface, surfacemethod, methodextraction, extractionenvironmental, environmentaldetection, detectionwaters