Validation of USEPA Method 524.2 Using a Stratum PTC and the New AQUATek 100 Autosampler
Aplikace | 2010 | Tekmar TeledyneInstrumentace
GC/MSD, Purge and Trap, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceAgilent Technologies, Tekmar Teledyne
Klíčová slovatert, temp, purge, bake, ether, butyl, butylbenzene, ptc, stratum, ethyl, condenser, desorb, methyl, tetrahydrofuran, time, preheat, methylethylketone, alcohol, benzene, chlorodifluoromethane, chloride, dipe, tba, flow, mek, mdl, tame, rinse, etbe, dry, toluene, dibromomethane, dichlorodifluoromethane, bromobenzene, trichlorofluoromethane, chloroethane, amyl, bromochloromethane, tetrachloroethene, isopropylbenzene, bromomethane, trichloroethene, chloromethane, thf, propylbenzene, dibromochloromethane, bromodichloromethane, parameters, bromoform, hexachlorobutadiene
Podobná PDF
Validation of USEPA Method 524.2 Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS
2010|PerkinElmer|Aplikace
Validation of USEPA Method 524.2Using a Stratum PTC, AQUATek 100Autosampler, and Perkin-ElmerClarus 600 GC/MSApplication NoteBy: Nathan ValentineAbstractThe US EPA developed Method 524.2¹, “Measurement of Purgeable Organic Compounds in Water byCapillary Column Gas Chromatography/Mass Spectrometry”, for identifying and measuring purgeablevolatile organic...
Klíčová slova
temp, temppurge, purgebake, bakedesorb, desorbcondenser, condensertime, timerinse, rinsebutylbenzene, butylbenzenedry, drypreheat, preheatflow, flowchloride, chloridemethacrylate, methacrylatedrain, drainacryl
Evaluating USEPA Method 524.3 Utilizing Newly Permissible Method Modifications to Purge and Trap Techniques
2009|Agilent Technologies|Aplikace
Evaluating USEPA Method 524.3Utilizing Newly Permissible MethodModifications to Purge and TrapTechniquesApplication NoteBy: Anne JurekAbstractPurge and Trap (P&T) concentration in conjunction with Gas Chromatography/Mass Spectrometry(GC/MS) is a widely used technique for the determination of Volatile Organic Compounds (VOCs). Dueto the sensitivity...
Klíčová slova
pass, passpurge, purgetemp, tempbake, bakeapp, appppb, ppbmodifications, modificationspir, pirdesorb, desorbchloride, chloridebutylbenzene, butylbenzenecondenser, condenserfail, failtime, timecompound
US EPA Method 524.2 with the Teledyne Tekmar Lumin P&T Concentrator and PerkinElmer® Clarus® 600 GC/Clarus® SQ8T MS
2016|PerkinElmer|Aplikace
US EPA Method 524.2 with theTeledyne Tekmar Lumin P&TConcentrator and PerkinElmer®Clarus® 600 GC/Clarus® SQ8T MSApplication NoteRoger Bardsley, Applications Chemist; Teledyne TekmarP a g e |1AbstractUS EPA Method 524.2 is used primarily by environmental labs for theanalysis of Volatile Organic Compounds...
Klíčová slova
temp, temppurge, purgebake, bakeether, etherppb, ppbtert, tertdesorb, desorbvariable, variabletable, tablebutylbenzene, butylbenzenersd, rsdtime, timedrain, drainlumin, lumincondenser
Using Nitrogen Purge Gas for US EPA Drinking Water Methods
2012|Agilent Technologies|Aplikace
Using Nitrogen Purge Gas for US EPADrinking Water MethodsApplication NoteAbstractThe USEPA developed Method 524.4, “Measurement of Purgeable Organic Compounds in Water byCapillary Column Gas Chromatography/Mass Spectrometry (Using Nitrogen Purge Gas)”, for identifyingand measuring purgeable volatile organic compounds in surface water,...
Klíčová slova
pass, passpurge, purgetemp, tempbake, bakedrinking, drinkingdesorb, desorbepa, epanitrogen, nitrogenwater, watercondenser, condensermethods, methodsppb, ppbtime, timegas, gasnote