Agilent 7010B Triple Quadrupole GC/MS System - Data Sheet

 

Podobná PDF

Toggle
Agilent 7000D Triple Quadrupole GC/MS System - Data Sheet
2016|Agilent Technologies|Brožury a specifikace
Agilent 7000D Triple Quadrupole GC/MS System Data Sheet The Agilent 7890B Gas Chromatograph combined with an Agilent 7000D Mass Spectrometer is the best choice for routine GC/MS/MS analysis with a low 4 fg Octafluoronaphthalene Instrument Detection Level (IDL) specification. The…
Klíčová slova
mrm, mrmparameter, parametervalue, valuefilaments, filamentsramps, rampstransition, transitionpci, pcispecifications, specificationsidl, idlcollision, collisionaxis, axisproprietary, proprietarysystem, systemvent, ventplateaus
Agilent 7000C Triple QuadrupoleGC/MS System - Data Sheet
2013|Agilent Technologies|Brožury a specifikace
Agilent 7000C Triple Quadrupole GC/MS System Data Sheet The 7890B Gas Chromatograph and 7000C Mass Spectrometer is the most sensitive GC/MS/MS system with the lowest, 4 fg Octafluoronaphthalene Instrument Detection Level (IDL) specification. The 4fg IDL is demonstrated upon installation,…
Klíčová slova
mrm, mrmidl, idlfilaments, filamentspci, pcisystem, systemcollision, collisionsheet, sheetaxis, axisquadrupole, quadrupoleiris, irished, hedspecifications, specificationstradition, traditionminimum, minimumdual
Agilent 7010 Triple Quadrupole GC/MS System - Data Sheet
2014|Agilent Technologies|Brožury a specifikace
Agilent 7010 Triple Quadrupole GC/MS System Data Sheet The Agilent 7890B Gas Chromatograph and Agilent 7010 Mass Spectrometer is the most sensitive GC/MS/MS system with the lowest, 0.5 fg Octafluoronaphthalene Instrument Detection Limit (IDL) specification (Preliminary). The IDL is demonstrated…
Klíčová slova
idl, idlmrm, mrmfilaments, filamentssystem, systemcollision, collisionaxis, axisoctafluoronaphthalene, octafluoronaphthaleneiris, irished, hedtradition, traditiondual, dualhexapole, hexapolewake, wakeagilent, agilentinstallation
Agilent 7000B Triple Quadrupole GC/MS System
2012|Agilent Technologies|Brožury a specifikace
Agilent 7000B Triple Quadrupole GC/MS System Data Sheet Agilent is leading the way by introducing IDL, Instrument Detection Limit, as a new metric for meaningful indication of system sensitivity. In MS/MS baselines with very little noise, the dubious selection of…
Klíčová slova
mrm, mrmpci, pciidl, idlfilaments, filamentsmodes, modeselectronic, electronicnci, ncipneumatic, pneumaticmore, morecollision, collisiontriple, triplesheet, sheetaxis, axiscustomary, customaryquadrupole