Method Development for Trace Level Detection of N-Nitrosamines in Beer by GC-MS/MS
Postery | 2013 | Shimadzu | ASMSInstrumentace
GC/MSD, GC/MS/MS, GC/QQQ
ZaměřeníPotraviny a zemědělství
VýrobceShimadzu
Klíčová slovanitrosamines, beer, nmor, npip, ndma, ndba, ndea, npyr, method, trace, ratio, area, development, level, ppb, detection, nitrite, mrm, spiked, detected, mode, systemically, ion, transition, were, six, nitrosopiperidine, extract, calibrants, ndpa, malt, quantification, linear, selected, name, scan, quantitative, carcinogenic, including, sample, meat, summarized, singapore, acquisition, rsd, beverages, amine, beyond, studied, cid
Podobná PDF
High Sensitivity Detection and Quantification of Trace Levels of N-Nitrosamines in Beers by GC-MS/MS Method
2013|Shimadzu|Aplikace
Application News AD-0057 GC-MS/MS High Sensitivity Detection and Quantification of Trace Levels of N-Nitrosamines in Beers by GC-MS/MS Method Most of N-nitrosamines are known to be carcinogenic and mutagenic. Consumption of nitrosamines, e.g., Nnitrosodimethylamine (NDMA), was reported to be a…
Klíčová slova
nmor, nmorndma, ndmanpyr, npyrnpip, npipbeer, beerndba, ndbanitrosamines, nitrosaminesndea, ndeappb, ppbsix, sixndpa, ndpaarea, arearatio, rationews, newsmrm
High Sensitivity Analysis of Nitrosamines Using GC-MS/MS
2012|Thermo Fisher Scientific|Aplikace
Alex Chen1, Hans-Joachim Huebschmann2, Li Fangyan3, Chew Yai Foong3 and Chan Sheot Harn3 Alpha Analytical Pte. Ltd., Singapore; 2Thermo Fisher Scientific, Singapore, 3Health Sciences Authority, HSA Singapore 1 Keywords: Nitrosamines, Food Safety, beer, TSQ 8000, GC-MS/MS, quantitation, confirmation, AutoSRM, TraceFinder…
Klíčová slova
nitrosamines, nitrosaminesetofenprox, etofenproxnitrosamine, nitrosaminenpyr, npyrnpip, npipfenamirol, fenamirolndba, ndbaindoxacarb, indoxacarbnmor, nmorfisher, fisherfluquinconazol, fluquinconazolazinphosmethyl, azinphosmethylndma, ndmandea, ndeasilafluofen
Screening of Nitrosamine Impurities in Drug Products and Drug Substances Using Agilent GC/MS/MS Instrumentation
2023|Agilent Technologies|Aplikace
Application Note Pharma & Biopharma Screening of Nitrosamine Impurities in Drug Products and Drug Substances Using Agilent GC/MS/MS Instrumentation Authors Abstract Carole Antoine, Milan Macé, Elodie Barrau, and Emmanuel Desmartin Eurofins Amatsi Analytics This application note highlights a comprehensive solution…
Klíčová slova
ndph, ndphnmpea, nmpeanmpa, nmpanitrosamines, nitrosaminesnmor, nmornmea, nmeanpyr, npyrnpip, npipneipa, neipandipa, ndipandma, ndmandpa, ndpandba, ndbandea, ndeanitrosamine
A validated method for the rapid determination of fifteen nitrosamines in metformin drug substance
2021|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE 10753 A validated method for the rapid determination of fifteen nitrosamines in metformin drug substance Authors: Dujuan Lu¹, Danny Hower1, Aaron Lamb2, Andrea Romano3, Dominic Roberts2 and Cristian Cojocariu2; 1 SGS, Fairfield NJ, USA, 2 Thermo Fisher Scientific,…
Klíčová slova
fda, fdapositive, positivenipea, nipeametformin, metforminndbea, ndbeaneba, nebanmpa, nmpanepha, nephandma, ndmandea, ndeandpha, ndphanpip, npipndba, ndbandipa, ndipanmor