CO2 Reduction Gas Products Analysis Using the Agilent 990 Micro GC
Aplikace | 2020 | Agilent TechnologiesInstrumentace
Increasing atmospheric CO2 concentrations from fossil fuel use present significant environmental challenges. Converting CO2 into value-added chemicals and fuels can close the carbon cycle, reduce greenhouse gas accumulation, and generate renewable energy carriers. Fast, accurate analysis of CO2 reduction products is essential to evaluate catalyst performance and optimize reaction conditions.
This study demonstrates the application of the Agilent 990 Micro GC for monitoring key CO2 reduction gas products. By employing two complementary separation channels, the work aims to achieve rapid, reproducible quantitation of H2, CO, CH4, C2H6, and C2H4. Quantitative precision and retention time stability are assessed over multiple analyses of a calibration standard.
Instrument configuration involved two independent channels:
Standard gas composition included H2 (98.7 ppm), CH4 (99.7 ppm), CO (491.9 ppm), C2H4 (49.6 ppm), and C2H6 (50.03 ppm) with CO2 balance.
Separation performance:
Repeatability over ten consecutive injections of the standard gas showed retention time RSD < 1% and peak area RSD < 3% for all components, indicating excellent precision for quantitative analysis.
The Agilent 990 Micro GC offers:
Advances in micro GC technology and column materials will further reduce analysis time and expand the detectable analyte range, including alcohols and oxygenates. Integration with automated sampling or inline reactor monitoring will enable real-time optimization of CO2 reduction processes. Machine learning algorithms may leverage high-throughput GC data for predictive catalyst design.
This application note confirms the Agilent 990 Micro GC as a robust tool for fast, precise analysis of CO2 reduction gas products. The dual-channel approach achieves complete separation of light gases and C2 hydrocarbons in under 3 minutes, with excellent repeatability, supporting both research and industrial process monitoring.
GC
ZaměřeníPrůmysl a chemie
VýrobceAgilent Technologies
Souhrn
Significance of the Topic
Increasing atmospheric CO2 concentrations from fossil fuel use present significant environmental challenges. Converting CO2 into value-added chemicals and fuels can close the carbon cycle, reduce greenhouse gas accumulation, and generate renewable energy carriers. Fast, accurate analysis of CO2 reduction products is essential to evaluate catalyst performance and optimize reaction conditions.
Objectives and Study Overview
This study demonstrates the application of the Agilent 990 Micro GC for monitoring key CO2 reduction gas products. By employing two complementary separation channels, the work aims to achieve rapid, reproducible quantitation of H2, CO, CH4, C2H6, and C2H4. Quantitative precision and retention time stability are assessed over multiple analyses of a calibration standard.
Methodology and Instrumentation
Instrument configuration involved two independent channels:
- Channel 1: 10 m Agilent CP-Molsieve 5Å column with 5 m precolumn backflush and RTS option. Carrier gas He at 180 kPa; injector and column at 60 °C; injection time 100 ms. Designed to separate H2, CH4, and CO and to remove CO2 and moisture via backflush for long-term stability.
- Channel 2: 10 m Agilent CP-PoraPLOT U straight column. Carrier gas He at 100 kPa; injector at 50 °C; column at 40 °C; injection time 20 ms. Optimized for CH4, CO2, C2H4, and C2H6 separation.
Standard gas composition included H2 (98.7 ppm), CH4 (99.7 ppm), CO (491.9 ppm), C2H4 (49.6 ppm), and C2H6 (50.03 ppm) with CO2 balance.
Main Results and Discussion
Separation performance:
- On the CP-Molsieve 5Å channel, H2, CH4, and CO were baseline separated within 2.5 minutes.
- On the CP-PoraPLOT U channel, CH4, CO2, C2H4, and C2H6 were resolved within 2 minutes, aided by precolumn backflush to remove CO2.
Repeatability over ten consecutive injections of the standard gas showed retention time RSD < 1% and peak area RSD < 3% for all components, indicating excellent precision for quantitative analysis.
Benefits and Practical Applications
The Agilent 990 Micro GC offers:
- Rapid cycle times (< 3 minutes) for routine screening of CO2 reduction products.
- High retention time stability and low maintenance due to precolumn backflush.
- Reliable quantitation with area repeatability below 3%, suitable for catalyst screening and process control in electrochemical, photochemical, or thermochemical CO2 conversion setups.
Future Trends and Applications
Advances in micro GC technology and column materials will further reduce analysis time and expand the detectable analyte range, including alcohols and oxygenates. Integration with automated sampling or inline reactor monitoring will enable real-time optimization of CO2 reduction processes. Machine learning algorithms may leverage high-throughput GC data for predictive catalyst design.
Conclusion
This application note confirms the Agilent 990 Micro GC as a robust tool for fast, precise analysis of CO2 reduction gas products. The dual-channel approach achieves complete separation of light gases and C2 hydrocarbons in under 3 minutes, with excellent repeatability, supporting both research and industrial process monitoring.
References
- van Loon R. Permanent Gas Analysis – Separation of Helium, Neon and Hydrogen on a MolSieve 5A column using the Agilent 490 Micro GC. Agilent Technologies Application Note 5990-8527EN, 2011.
- van Loon R. C1–C3 Hydrocarbon Analysis Using the Agilent 490 Micro GC – Separation Characteristics for PoraPLOT U and PoraPLOT Q Column Channels. Agilent Technologies Application Note 5990-9165EN, 2011.
Obsah byl automaticky vytvořen z originálního PDF dokumentu pomocí AI a může obsahovat nepřesnosti.
Podobná PDF
CO2 Reduction Gas Products Analysis Using the Agilent 990 Micro GC
2020|Agilent Technologies|Aplikace
Application Note Energy & Chemicals CO2 Reduction Gas Products Analysis Using the Agilent 990 Micro GC Author Fei Jiang Agilent Technologies, Inc. Abstract This application note describes the use of the Agilent 990 Micro GC for CO2 for reduction gas…
Klíčová slova
poraplot, poraplotcarbon, carbonrts, rtsmonoxide, monoxidehydrogen, hydrogenethane, ethanemethane, methaneenergy, energydioxide, dioxideethylene, ethylenefei, feiclimatic, climaticintensively, intensivelyjiang, jiangresearched
Biomass Pyrolysis Gas Products Analysis Using the Agilent 990 Micro GC
2022|Agilent Technologies|Aplikace
Application Brief Energy and Chemicals Biomass Pyrolysis Gas Products Analysis Using the Agilent 990 Micro GC Author Fei Jiang Agilent Technologies (China) Co. Ltd. Shanghai 200080 P. R. China Abstract This application note describes the use of the Agilent 990…
Klíčová slova
biomass, biomasspyrolysis, pyrolysiscarbon, carbonsustainable, sustainablemonoxide, monoxideacetylene, acetyleneethane, ethanemol, molretention, retentionmethane, methanedioxide, dioxideethylene, ethylenetime, timechannel, channelfei
The Analysis of Swelling Gas in Lithium-Ion Batteries with an Agilent 990 Micro GC
2020|Agilent Technologies|Aplikace
Application Note Energy & Chemicals The Analysis of Swelling Gas in Lithium-Ion Batteries with an Agilent 990 Micro GC Author Jie Zhang Agilent Technologies, Inc. Abstract This application note describes the analysis of lithium-ion-battery swelling gas using an Agilent 990…
Klíčová slova
swelling, swellingmol, molcalibration, calibrationgas, gasretention, retentionlibs, libsvri, vricomponent, componenttime, timemin, minari, arihexane, hexanechannel, channelbattery, batterysample
Coal Mine Gas Analysis with the Agilent 990 Micro GC
2023|Agilent Technologies|Aplikace
Application Brief Energy & Chemicals Coal Mine Gas Analysis with the Agilent 990 Micro GC Author Jie Zhang Agilent Technologies (Shanghai) Co. Ltd. Abstract In this application brief, a fast coal mine gas analysis was performed on an Agilent 990…
Klíčová slova
ppu, ppumolsieve, molsievechannel, channelresponse, responsebackflush, backflushppq, ppqgas, gasmine, minecoal, coalagilent, agilentcarrier, carrierhelium, heliumtime, timemol, molargon