2016|Trajan Scientific|Aplikace
APPLICATION NOTEAnalysis of a phenols mixtureBPX5Column part number054101PhaseBPX5Carrier gas flow2.1 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample200 ppm in methanolAverage linear velocity35 cm/sec at 80°CInitial temperature80°C, 1 minInjection modeSplit (100:1)Rate10°C/minInjection volume1 μLFinal temperature300°C, 5 minInjection temperature250°CDetectorMSLiner type4 mm...
Klíčová slova
temperature, temperatureinjection, injectionphenols, phenolscarrier, carriervelocity, velocitysim, simflow, flowconstant, constantgas, gasliner, linerfinal, finalmixture, mixtureinitial, initialcolumn, columnaverage
APPLICATION NOTEAnalysis of chlorinated and nitroaromatic compoundsSolGel-1msTMColumn part number054795PhaseSolGel-1msTMCarrier gas flow1.8 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample200 ppm in dichloromethaneAverage linear velocity35 cm/sec, 40°CInitial temperature40°C, 1 minInjection modeSplit (100:1)Rate10°C/minInjection volume0.5 μLFinal temperature300°C, 2 minInjection temperature250°CDetectorMSLiner type4 mm...
Klíčová slova
nitroaromatic, nitroaromatictemperature, temperatureinjection, injectionpentachlorophenol, pentachlorophenolcarrier, carrierhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simflow, flowconstant, constantgas, gasliner, linerfinal, finalinitial
APPLICATION NOTEAnalysis of chlorinated and nitroaromatic compoundsBPX35Column part number054701PhaseBPX35Carrier gas flow1.8 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample10 ppm in methanolAverage linear velocity35 cm/sec, 40°CInitial temperature40°C, 1 minInjection modeSplit (100:1)Rate 130°C/min to 200°CInjection volume1 μLRate 24°C/min to 300°CInjection...
Klíčová slova
nitroaromatic, nitroaromatictemperature, temperatureinjection, injectionpentachlorophenol, pentachlorophenolcarrier, carrierhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simflow, flowconstant, constantgas, gasliner, linerfinal, finalinitial
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Aplikace
APPLICATION NOTEAnalysis of USEPA 8270 mixBPX5Column part number054101PhaseBPX5Carrier gas flow1.1 mL/minColumn30 m x 0.25 mm x 0.25 μmConstant flowOnSample5 ppm solutionInjection modeSplitlessInitial temperature40°C, 3 minPurge on time0.5 minRate8°C/min to 300°CPurge on (split) vent flow40 mL/minFinal temperature300°C, 9 minInjection volume1 μLDetectorMSInjection...
Klíčová slova
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzoanthracene, anthracenepyrene, pyrenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoletemperature, temperatureazobenzene, azobenzenebenzidine
 

Podobná PDF

Toggle
Analysis of a phenols mixture
2016|Trajan Scientific|Aplikace
APPLICATION NOTEAnalysis of a phenols mixtureBPX5Column part number054101PhaseBPX5Carrier gas flow2.1 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample200 ppm in methanolAverage linear velocity35 cm/sec at 80°CInitial temperature80°C, 1 minInjection modeSplit (100:1)Rate10°C/minInjection volume1 μLFinal temperature300°C, 5 minInjection temperature250°CDetectorMSLiner type4 mm...
Klíčová slova
temperature, temperatureinjection, injectionphenols, phenolscarrier, carriervelocity, velocitysim, simflow, flowconstant, constantgas, gasliner, linerfinal, finalmixture, mixtureinitial, initialcolumn, columnaverage
APPLICATION NOTEAnalysis of chlorinated and nitroaromatic compoundsSolGel-1msTMColumn part number054795PhaseSolGel-1msTMCarrier gas flow1.8 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample200 ppm in dichloromethaneAverage linear velocity35 cm/sec, 40°CInitial temperature40°C, 1 minInjection modeSplit (100:1)Rate10°C/minInjection volume0.5 μLFinal temperature300°C, 2 minInjection temperature250°CDetectorMSLiner type4 mm...
Klíčová slova
nitroaromatic, nitroaromatictemperature, temperatureinjection, injectionpentachlorophenol, pentachlorophenolcarrier, carrierhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simflow, flowconstant, constantgas, gasliner, linerfinal, finalinitial
APPLICATION NOTEAnalysis of chlorinated and nitroaromatic compoundsBPX35Column part number054701PhaseBPX35Carrier gas flow1.8 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample10 ppm in methanolAverage linear velocity35 cm/sec, 40°CInitial temperature40°C, 1 minInjection modeSplit (100:1)Rate 130°C/min to 200°CInjection volume1 μLRate 24°C/min to 300°CInjection...
Klíčová slova
nitroaromatic, nitroaromatictemperature, temperatureinjection, injectionpentachlorophenol, pentachlorophenolcarrier, carrierhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simflow, flowconstant, constantgas, gasliner, linerfinal, finalinitial
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Aplikace
APPLICATION NOTEAnalysis of USEPA 8270 mixBPX5Column part number054101PhaseBPX5Carrier gas flow1.1 mL/minColumn30 m x 0.25 mm x 0.25 μmConstant flowOnSample5 ppm solutionInjection modeSplitlessInitial temperature40°C, 3 minPurge on time0.5 minRate8°C/min to 300°CPurge on (split) vent flow40 mL/minFinal temperature300°C, 9 minInjection volume1 μLDetectorMSInjection...
Klíčová slova
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzoanthracene, anthracenepyrene, pyrenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoletemperature, temperatureazobenzene, azobenzenebenzidine
 

Mohlo by Vás zajímat

Utilising unique TOF-MS technology and hydrogen carrier gas for fast GC-MS to produce robust, high quality, library comparable mass spectral data

Postery
| 2022 | LECO
Instrumentace
GC/MSD, GC/TOF
Výrobce
LECO
Zaměření
---

Determination of BTEX and volatile organic compounds (VOCs) in drinking water by GC-MS/MS coupled to static headspace and solid-phase microextraction sampling

Aplikace
| 2022 | Thermo Fischer Scientific
Instrumentace
GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ
Výrobce
Thermo Fischer Scientific
Zaměření
Životní prostředí

Analysis of Trace Perfluorinated and Polyfluorinated Organic Vapors in Air

Aplikace
| 2022 | Agilent Technologies
Instrumentace
GC/MSD, Termální desorpce, GC/SQ
Výrobce
Agilent Technologies, Markes
Zaměření
Životní prostředí

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GC/MS System

Aplikace
| 2022 | Shimadzu
Instrumentace
GC/MSD, HeadSpace, GC/SQ
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

Analysis of Heavy Fuel Oil Using Multi-Mode Ionization

Aplikace
| 2022 | LECO
Instrumentace
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Výrobce
LECO
Zaměření
Průmysl a chemie
 

Mohlo by Vás zajímat

Utilising unique TOF-MS technology and hydrogen carrier gas for fast GC-MS to produce robust, high quality, library comparable mass spectral data

Postery
| 2022 | LECO
Instrumentace
GC/MSD, GC/TOF
Výrobce
LECO
Zaměření
---

Determination of BTEX and volatile organic compounds (VOCs) in drinking water by GC-MS/MS coupled to static headspace and solid-phase microextraction sampling

Aplikace
| 2022 | Thermo Fischer Scientific
Instrumentace
GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ
Výrobce
Thermo Fischer Scientific
Zaměření
Životní prostředí

Analysis of Trace Perfluorinated and Polyfluorinated Organic Vapors in Air

Aplikace
| 2022 | Agilent Technologies
Instrumentace
GC/MSD, Termální desorpce, GC/SQ
Výrobce
Agilent Technologies, Markes
Zaměření
Životní prostředí

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GC/MS System

Aplikace
| 2022 | Shimadzu
Instrumentace
GC/MSD, HeadSpace, GC/SQ
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

Analysis of Heavy Fuel Oil Using Multi-Mode Ionization

Aplikace
| 2022 | LECO
Instrumentace
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Výrobce
LECO
Zaměření
Průmysl a chemie