Analysis of a phenols mixtureAplikace | 2016 | Trajan Scientific InstrumentaceGC/MSD, GC kolony, Spotřební materiálVýrobceTrajan ScientificKlíčová slova
Podobná PDF
APPLICATION NOTEAnalysis of a phenols mixtureBPX5Column part number054101PhaseBPX5Carrier gas flow2.1 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample200 ppm in methanolAverage linear velocity35 cm/sec at 80°CInitial temperature80°C, 1 minInjection modeSplit (100:1)Rate10°C/minInjection volume1 μLFinal temperature300°C, 5 minInjection temperature250°CDetectorMSLiner type4 mm...
Klíčová slova
temperature, temperatureinjection, injectionphenols, phenolscarrier, carriervelocity, velocitysim, simflow, flowgas, gasconstant, constantliner, linerfinal, finalmixture, mixtureinitial, initialcolumn, columnaverage
APPLICATION NOTEAnalysis of chlorinated and nitroaromatic compoundsSolGel-1msTMColumn part number054795PhaseSolGel-1msTMCarrier gas flow1.8 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample200 ppm in dichloromethaneAverage linear velocity35 cm/sec, 40°CInitial temperature40°C, 1 minInjection modeSplit (100:1)Rate10°C/minInjection volume0.5 μLFinal temperature300°C, 2 minInjection temperature250°CDetectorMSLiner type4 mm...
Klíčová slova
nitroaromatic, nitroaromatictemperature, temperatureinjection, injectionpentachlorophenol, pentachlorophenolcarrier, carrierhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simflow, flowgas, gasconstant, constantliner, linerfinal, finalinitial
APPLICATION NOTEAnalysis of chlorinated and nitroaromatic compoundsBPX35Column part number054701PhaseBPX35Carrier gas flow1.8 mL/minColumn30 m x 0.25 mm x 0.25 µmConstant flowOnSample10 ppm in methanolAverage linear velocity35 cm/sec, 40°CInitial temperature40°C, 1 minInjection modeSplit (100:1)Rate 130°C/min to 200°CInjection volume1 μLRate 24°C/min to 300°CInjection...
Klíčová slova
nitroaromatic, nitroaromatictemperature, temperatureinjection, injectionpentachlorophenol, pentachlorophenolcarrier, carrierhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simflow, flowgas, gasconstant, constantliner, linerfinal, finalinitial
APPLICATION NOTEAnalysis of USEPA 8270 mixBPX5Column part number054101PhaseBPX5Carrier gas flow1.1 mL/minColumn30 m x 0.25 mm x 0.25 μmConstant flowOnSample5 ppm solutionInjection modeSplitlessInitial temperature40°C, 3 minPurge on time0.5 minRate8°C/min to 300°CPurge on (split) vent flow40 mL/minFinal temperature300°C, 9 minInjection volume1 μLDetectorMSInjection...
Klíčová slova
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzoanthracene, anthracenepyrene, pyrenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoleazobenzene, azobenzenetemperature, temperaturebenzidine