Haloacetic Acid Analysis by the Agilent Intuvo 9000 Dual ECD System
Aplikace | 2021 | Agilent TechnologiesInstrumentace
GC
ZaměřeníŽivotní prostředí
VýrobceAgilent Technologies
Klíčová slovaacid, haa, haloacetic, dalapon, were, response, ecd, columns, methyl, tribromoacetic, bromochloroacetic, drinking, dichloroacetic, bromodichloroacdetic, dibromoacdtic, haas, trichloroacetic, intuvo, acids, chlorodibromoacetic, chip, monobromoacetic, cdbaa, helium, monochloroacetic, nitrogen, bdcaa, water, mbaa, tbaa, calibration, bcaa, dbaa, tcaa, esters, mcaa, dcaa, inlet, flow, splitless, carrier, evaluated, than, generated, track, analysis, retention, make, eisele, oven
Podobná PDF
Determination of Haloacetic Acids in Drinking Water According to EPA Method 552.3 using Hydrogen Carrier Gas
2020|Shimadzu|Aplikace
No. SSI-GC-2002 Gas Chromatography No. GC-2002 Determination of Haloacetic Acids in Drinking Water According to EPA Method 552.3 using Hydrogen Carrier Gas ■ Abstract Haloacetic acids (HAAs) are known carcinogens that may occur as disinfection byproducts in drinking water. Currently…
Klíčová slova
ratio, ratiodalapon, dalaponcdbaa, cdbaabdcaa, bdcaaarea, areambaa, mbaabcaa, bcaatbaa, tbaadbaa, dbaatcaa, tcaamcaa, mcaadcaa, dcaahaas, haashaloacetic, haloaceticcarrier
Can we keep the cost of analysis of haloaceticacids (HAAs) down by using an alternative to Helium?
|Shimadzu|Postery
Can we keep the cost of analysis of haloacetic acids (HAAs) down by using an alternative to Helium? Yuan Lin, Nicole Lock and Ruth Marfil-Vega, Shimadzu Scientific Instruments, Columbia, MD, USA Introduction Comparison of hydrogen to helium as carrier gas…
Klíčová slova
ratio, ratioarea, areacdbaa, cdbaabdcaa, bdcaambaa, mbaatbaa, tbaabcaa, bcaadbaa, dbaatcaa, tcaamcaa, mcaadcaa, dcaadalapon, dalaponacid, acidhaloacetic, haloacetichelium
Determination of Haloacetic Acids in Water by GC/μECD Using Agilent J&W DB-35ms Ultra Inert and DB-XLB Columns
2011|Agilent Technologies|Aplikace
Determination of Haloacetic Acids in Water by GC/µECD Using Agilent J&W DB-35ms Ultra Inert and DB-XLB Columns Application Note Environmental, Water Quality Authors Abstract Doris Smith and Ken Lynam Haloacetic acids (HAAs) in water samples are effectively extracted and Agilent…
Klíčová slova
methyl, methylhaas, haashaloacetic, haloaceticdibromochloroacetate, dibromochloroacetatexlb, xlbbromochloroacetate, bromochloroacetatebromodichloroacetate, bromodichloroacetatebromoacetate, bromoacetatedibromoacetate, dibromoacetatetribromoacetate, tribromoacetatechloroacetate, chloroacetatetrichloroacetate, trichloroacetatedalapon, dalapondichloroacetate, dichloroacetateester
Fast Determination of Haloacetic Acids in Drinking Water According to EPA Method 552.3 using Rtx-CLPesticides Columns and Hydrogen Carrier Gas
2020|Shimadzu|Aplikace
No. SSI-GC-2004 Gas Chromatography No. GC-2004 Fast Determination of Haloacetic Acids in Drinking Water According to EPA Method 552.3 using Rtx-CLPesticides Columns and Hydrogen Carrier Gas ■ Abstract Haloacetic acids (HAAs) are known carcinogens that may occur as disinfection byproducts…
Klíčová slova
ratio, ratioarea, areacdbaa, cdbaabdcaa, bdcaambaa, mbaabcaa, bcaatbaa, tbaadbaa, dbaatcaa, tcaamcaa, mcaadcaa, dcaaclp, clpepa, epadalapon, dalaponrtx