Highly Sensitive Analysis of Estradiols Using NCI-GC/MS
Aplikace | | ShimadzuInstrumentace
GC/MSD, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceShimadzu
Klíčová slovaderivatization, nci, estradiols, pfb, hexane, tms, imidasol, sediments, sim, trimethylsilyl, minicolumn, dehydrate, pentafluorobenzyl, method, rinse, surrogates, elisa, estradiol, water, add, dryness, substances, achieves, derivatized, surrogate, derivatizes, estron, dichloromethane, methanol, gel, scan, layer, ethynyl, dry, extraction, gccolumn, silica, inspecting, attracting, samples, biological, gaschromatography, estriol, spiked, extracted, preservation, florisil, solid, manuals, measurement
Podobná PDF
Analysis of Nitroglycerin Metabolites in Blood Plasma Using NCI-GC/M
2022|Shimadzu|Aplikace
GC-MS GCMS-QP™ Series Application News Analysis of Nitroglycerin Metabolites in Blood Plasma Using NCI-GC/MS Yuki Sakamoto1, Natsuka Kimura2, and Kenichi Aizawa2 1 Shimadzu Corporation, 2 Jichi Medical University User Benefits NCI-GC/MS analysis can detect nitroglycerin metabolites and nitric acid…
Klíčová slova
nitroglycerin, nitroglyceringtn, gtnnci, nciratio, ratioglyceryl, glycerylmetabolites, metabolitesgmn, gmniodobenzyl, iodobenzylnitrate, nitrategdn, gdnmononitrate, mononitratenews, newstriethylamine, triethylaminenitric, nitricdinitrate
Approaching The Ultimate Limits of Detection For Endocrine Disruptors in Wastewater Effluent Using GC-NCI-MS/MS
2013|Agilent Technologies|Postery
Approaching The Ultimate Limits of Detection For Endocrine Disruptors in Wastewater Effluent Using GC-NCI-MS/MS Melissa Churley1, Ruth-Marfil-Vega2, Marc Mills3 and Anthony Macherone4,5 1Agilent Technologies, Inc., Santa Clara, CA; 2 American Water, Belleville, IL; 3 National Risk Management Research Laboratory (NRMRL),…
Klíčová slova
steroidal, steroidaltestosterone, testosteroneestrogens, estrogensanalogs, analogsnci, nciendocrine, endocrinedev, devamenable, amenableequlilin, equlilininection, inectiongcnci, gcnciwastewater, wastewateragency, agencyasd, asdmarfil
Derivatization Procedure and Negative Chemical Ionization GC/MS/MS Conditions for the Analysis of Steroidal Analogs
2012|Agilent Technologies|Aplikace
Derivatization Procedure and Negative Chemical Ionization GC/MS/MS Conditions for the Analysis of Steroidal Analogs Application Note Clinical Research Author Abstract Anthony Macherone, Ph.D. This application note describes a chemical derivatization procedure required to facili- Agilent Technologies, Inc. tate measurement of…
Klíčová slova
steroidal, steroidalchemical, chemicalanalogs, analogstestosterone, testosteronederivatization, derivatizationesterification, esterificationnegative, negativepentaflurobenzoyl, pentaflurobenzoyloximation, oximationprocedure, proceduresrm, srmestradiol, estradiolthrough, throughandrogens, androgensamenable
Analysis of Estrone and 17β-Estradiol in Ground Water by GC-NCI-MS/MS
2011|Agilent Technologies|Postery
Analysis of Estrone and 17β 17β-Estradiol in Ground Water by GCGC-NCI NCI--MS/MS ASMS 2011 WP 316 2Robert Melissa M li Ch l 1Anthony Churley, A th M h Macherone, R b t Whit White 1 Agilent Technologies, Technologies Inc Inc.…
Klíčová slova
andd, anddlev, levnci, ncispiked, spikedmpa, mpadht, dhtoff, offnor, norestrogens, estrogensstudyy, studyynon, nonpfb, pfbspike, spikeect, ecteffluent