Analysis of aromatics in gasoline by ASTM D5769 using gas chromatography–single quadrupole mass spectrometry
Aplikace | 2022 | Thermo Fisher ScientificInstrumentace
GC/MSD, GC/SQ
ZaměřeníPrůmysl a chemie
VýrobceThermo Fisher Scientific
Klíčová slovaaromatics, vol, minutes, gasoline, counts, compound, targeted, total, pass, min, quadrupole, deuterated, accuracy, time, towards, standard, separation, linear, scan, concentration, internal, enabling, hold, relative, thermo, benzene, uncalibrated, electron, tic, liner, gra, single, xlxr, certified, retention, goal, maintenance, evaluated, intensity, split, spectral, ion, temperature, extractabrite, quantification, isooctane, achieved, producers, response, full
Podobná PDF
GCC: A Fresh Approach to ASTM D5769 Analysis using a Thermo Scientific ISQ 7610 Single Quadrupole GCMS
2022|Thermo Fisher Scientific|Prezentace
A Fresh Approach to ASTM D5769 Analysis using a Thermo Scientific ISQ 7610 Single Quadrupole GCMS Amit Gujar, Kenneth Free and James Pachlhofer Thermo Fisher Scientific, Austin, TX, USA The world leader in serving science 1 [email protected] | 12-October-2022 Agenda…
Klíčová slova
lin, lingra, graaccustandard, accustandardxlxr, xlxrxylene, xylenecatalog, catalogdetector, detectorcriteria, criteriaaromatics, aromaticselectrometer, electrometerindan, indanmin, minmodules, modulesbenzene, benzenetoluene
Fast GC/MS Analysis for Benzene and Total Aromatic Content of Motor Gasoline
2020|Agilent Technologies|Aplikace
Application Note Energy & Chemicals Fast GC/MS Analysis for Benzene and Total Aromatic Content of Motor Gasoline Author George Gonzalez and Fred Feyerherm Agilent Technologies, Inc. Nick Delone Bureau Veritas Abstract This application note presents the performance of an Agilent…
Klíčová slova
rfg, rfgastm, astmaromatics, aromaticsptp, ptptoluene, toluenebenzene, benzenecalibration, calibrationperformance, performancestandard, standardintuvo, intuvooperating, operatingtesting, testinggasoline, gasolineexcellent, excellenttotal
A High Performance and Cost‑Effective GC/MS Solution for Measuring Aromatics in Gasoline Using ASTM Method D5769
2020|Agilent Technologies|Aplikace
Application Note Energy and Chemical A High Performance and Cost‑Effective GC/MS Solution for Measuring Aromatics in Gasoline Using ASTM Method D5769 Author James D. McCurry Agilent Technologies, Inc. Abstract This application note describes an Agilent 8860/5977 gas chromatography/mass spectrometry (GC/MS)…
Klíčová slova
gasoline, gasolinetoluene, toluenearomatics, aromaticsreformulated, reformulatedils, ilsaromatic, aromatictotal, totalxylene, xylenecalibration, calibrationpentamethylbenzene, pentamethylbenzeneabundance, abundanceeic, eiclinearity, linearitytier, tierresponse
Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System
2003|Agilent Technologies|Aplikace
Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808-1610 USA Abstract The new…
Klíčová slova
gasoline, gasolinesource, sourceastm, astmaromatics, aromaticslinearity, linearityextended, extendedremedies, remediesabundance, abundanceconstruct, construction, ionaromatic, aromaticsaturation, saturationcalibration, calibrationoptional, optionalcurves