USEPA Methods 502.2 and 8021B using the Eclipse Purge-and-Trap (P&T) Sample Concentrator and PID/ELCD Tandem Detectors
Aplikace | | OI AnalyticalInstrumentace
GC, Purge and Trap
ZaměřeníŽivotní prostředí
VýrobceAgilent Technologies, OI Analytical
Klíčová slovayes, pid, elcd, butylbenzene, photoionization, purge, eclipse, trap, phdetect, detector, mdl, xylene, electrolytic, dibromochloromethane, bromodichloromethane, conductivity, desorb, detectors, chloride, precision, analyte, accuracy, fluorobenzene, detected, temperature, isopropyltoluene, study, tandem, dibromomethane, dichlorodifluoromethane, trichlorofluoromethane, bromobenzene, chloroethane, saver, bromochloromethane, tetrachloroethene, isopropylbenzene, bromomethane, trichloroethene, chloromethane, propylbenzene, bake, concentrator, bromoform, hexachlorobutadiene, detecotor, electrolyic, chlorobenzene, vinyl, tetrachloride
Podobná PDF
Optimizing the Analysis of Volatile Organic Compounds
2003|Restek|Příručky
Technical Guide 1 Optimizing the Analysis of Volatile Organic Compounds Inside: EPA Method Definitions State GRO Methods Contract Laboratory Program (CLP) The Love Canal Scandal Purge and Trap Theory Sequences and Flow Paths of the Purge and Trap Unit Purge…
Klíčová slova
pack, packxylene, xylenertx, rtxtert, tertpid, pidbutylbenzene, butylbenzenepurge, purgeelcd, elcdeach, eachchloride, chloridetrap, trapbenzene, benzenedata, dataacetate, acetatevgc
Analysis of BTEX-MTBE by Purge and Trap (P&T) Concentration and Determination by Gas Chromatography and Photoionization Detection (GC/PID)
|Agilent Technologies|Aplikace
Analysis of BTEX-MTBE by Purge and Trap (P&T) Concentration and Determination by Gas Chromatography and Photoionization Detection (GC/PID) Introduction The analysis of Benzene, Toluene, Ethylbenzene, Xylenes, and Methyl-tert-butyl ether is a common analysis performed in many laboratories. BTEX compounds are…
Klíčová slova
mtbe, mtbepid, pidpurge, purgebtex, btexphotoionization, photoionizationtrap, trapidp, idpgas, gasrec, recconcentration, concentrationdesorb, desorbtemperature, temperaturedetermination, determinationethylbenzene, ethylbenzenexylene
Volatile organic compounds in water by purge and trap/capillary column GC with photoionization and electrolytic conductivity detectors in series
2011|Agilent Technologies|Aplikace
Volatile organic compounds in water by purge and trap/capillary column GC with photoionization and electrolytic conductivity detectors in series Application Note Environmental Authors Introduction Agilent Technologies, Inc. The 1986 amendments to the Safe Drinking Water Act require the determination of…
Klíčová slova
vocs, vocselcd, elcdphotoionization, photoionizationpid, piddetectors, detectorscolumn, columnratioing, ratioingidentification, identificationtrap, trapvolatile, volatilecompounds, compoundsselector, selectorelectrolytic, electrolyticorganic, organicaromatics
Volatile Organics US EPA Method 8021 Rtx®-VRX
|Thermo Fisher Scientific|Aplikace
Volatile Organics US EPA Method 8021 Rtx®-VRX 39/40 PID • Good choice for waste water analysis. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24.…
Klíčová slova
butylbenzene, butylbenzenetert, tertvrx, vrxpid, pidxylene, xylenefluorobenzene, fluorobenzenebenzene, benzenertx, rtxether, etherbutyl, butylelcd, elcdchloride, chloridesilcosteel, silcosteelmethyl, methylisopropyltoluene