GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

Analysis of Oil and Fat containing foods by fully automated sample preparation using a PAL3 coupled with a 7890 GC and a 5977 MSD system according to AOAC 996.01

 

Podobná PDF

Toggle
Now There’s A WAX Column That Can Take The Heat
2018|Agilent Technologies|Ostatní
Now There’s A WAX Column That Can Take The Heat Introducing: Agilent J&W DB-HeavyWAX GC columns Extend operating temperature limits while maintaining WAX selectivity Proof of thermal stability: Standard WAX column vs. Agilent J&W DB-HeavyWAX column WAX GC columns can…
Klíčová slova
heavywax, heavywaxwax, waxagilent, agilentcolumn, columnmaximum, maximumcolumns, columnsbleed, bleedtemperature, temperatureindustrial, industrialisomeranzin, isomeranzinmeranzin, meranzinoperating, operatingosthole, ostholetemperatures, temperaturesincreased
New High Temperature PEG GC Column with Increased Temperature Limit and Ultra-Low Bleed Level Introduction Today’s demanding GC and GC/MS applications mainly focus on sensitive and reproducible qualitative and quantitative analysis of more challenging analytes. Gas chromatography columns based on…
Klíčová slova
heavywax, heavywaxwax, waxbleed, bleedagilent, agilentpolysiloxane, polysiloxaneultra, ultradbheavywax, dbheavywaxstremple, strempleindustrial, industrialbtx, btxcolumn, columnlevel, levelstationary, stationarygulf, gulfcoast
Application Note Industrial Chemicals Increased thermal stability and maximum temperature of the Agilent J&W DB-HeavyWAX column Authors Vanessa Abercrombie and Laura Provoost Agilent Technologies, Inc. Abstract One-hundred percent polyethylene glycol columns, also known as WAX columns, are used for a…
Klíčová slova
heavywax, heavywaxwax, waxcolumn, columnstability, stabilitytraditional, traditionalthermal, thermaltemperature, temperaturebtex, btexmaximum, maximumpeg, pegoperating, operatingcommercially, commerciallyimproved, improvedagilent, agilentcolumns
WAX Column Technology Update
2018|Agilent Technologies|Prezentace
WAX Column Technology Update Mark Sinnott August 14, 2018 1 August 14, 2018 Agilent J&W DB-HeavyWAX WAX Column Update • What is a WAX column? • Traditional WAX Phases • • • • • • 2 DB-WAX HP-INNOWAX VF-WAX MS…
Klíčová slova
heavywax, heavywaxwax, waxfatwax, fatwaxagilent, agilentcolumn, columnacids, acidsinert, inertcompetitor, competitordha, dhaacid, acidfame, fameffap, ffapbleed, bleedultra, ultratraditional
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.