Screening and identification of several toxic additives in tobacco using automated difficult matrix introduction (DMI) and GC-MS with a LINer EXchanger (LINEX)Aplikace | | GL Sciences InstrumentaceGC/MSD, GC/SQZaměřeníPotraviny a zemědělstvíVýrobceShimadzu, GL SciencesKlíčová slovadmi, tobacco, linex, atas, marlboro, degradate, drum, additives, international, knows, difficult, liner, several, pink, government, bad, automated, brings, taste, exchanger, reasons, line, matrix, losses, responsible, introduction, additive, started, manufacturer, cover, toxic, exposure, black, focus, optimum, together, therefore, industry, light, major, kind, helium, those, example, screening, tool, potential, step, increased, because
Podobná PDF
Automated difficult matrix introduction (DMI) for identification of allergens and fragrances in washing powder with GC-MS-Olfactometry and a liner exchanger (LINEX)
|Shimadzu|Aplikace
Application Note No. 102 (February 2006)Automated difficult matrix introduction (DMI) for identification of allergens andfragrances in washing powder with GC-MS-Olfactometry and a liner exchanger(LINEX)Key Words:Automated sample preparationDifficult Matrix Introduction (DMI)GC-MS-OlfactoryAllergens, fragrancesWashing powderErwin Kaal, Iwan HorstingTable 1: Repeatability (area) of several...
Klíčová slova
dmi, dmipowder, powderglycol, glycolatas, ataswashing, washinglinex, linexdifficult, difficultinternational, internationalfragrances, fragrancestriehtylene, triehtylenemonododecyl, monododecylpentaethylene, pentaethyleneperfumed, perfumedethylene, ethyleneautomated
Automated difficult matrix introduction (DMI) for identification of residues of washing powder on clothing with GC-MS and a LINer EXchanger (LINEX)
|Shimadzu|Aplikace
Application Note No. 103 (April 2006)Automated difficult matrix introduction (DMI) for identification of residues ofwashing powder on clothing with GC-MS and a LINer EXchanger (LINEX)Key Words:Automated Difficult Matrix Introduction (DMI)*GC-MSAllergens, fragrancesWashing powderErwin Kaal, Iwan HorstingIntroductionWashing powderResidue on clothing(x1,000,000)108.00 (1.00)Sample preparation...
Klíčová slova
dmi, dmiwashing, washingpowder, powderclothing, clothingcotton, cottonresidue, residuelinex, linexatas, atasalmost, almostmatrix, matrixsample, samplewashed, washedliner, linervolatile, volatilewhole
Automated difficult matrix introduction (DMI) for identification of allergens and fragrances in shampoo with GC-MS-Olfactometry and a liner exchanger (LINEX)
|Shimadzu|Aplikace
Application Note No. 101 (February 2006)Automated difficult matrix introduction (DMI) for identification of allergens andfragrances in shampoo with GC-MS-Olfactometry and a liner exchanger(LINEX)Key Words:Automated sample preparationDifficult matrix introduction (DMI)GC-MS-olfactrometryAllergens, fragrancesShampooErwin Kaal, Iwan HorstingIntroductionGC-MS analysis of shampoo is generally difficultbecause the...
Klíčová slova
shampoo, shampoodmi, dmilinex, linexatas, atasolfactrometry, olfactrometryinternational, internationalexchanger, exchangerdifficult, difficultcompounds, compoundssmelly, smellytetradecanol, tetradecanolautomated, automatedphaser, phasershampoos, shampoosmatrix
Application Note No. 060Analysis of the Nicotine content in Tobacco by Focus Direct TD–GC/MSSjaak de Koning.Direct desorption from sample matrix to columnNo manual sample preparationMay be automated using the Focus and LINEXInstrumentationOptic 2-200 programmable injectorFocus Direct-TD automated thermal desorberATAS SepLinerAgilent...
Klíčová slova
sepliner, seplinertobacco, tobaccofocus, focusdirect, directplace, placenicotine, nicotinecigar, cigarlinex, linexatas, atassample, sampleautomatically, automaticallyweigh, weighdesorber, desorberoptic, opticautomated