Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database
Aplikace | 2006 | Agilent TechnologiesInstrumentace
GC, GC/MSD, GC/SQ
ZaměřeníNebezpečné látky
VýrobceAgilent Technologies
Klíčová slovamethyl, fpd, amdis, sim, ester, phthalate, msd, split, scan, ecd, hazardous, splitter, dfpd, isomer, parathion, epc, endosulfan, min, tripropyl, ethyl, chemstation, bhc, match, restrictor, agilent, targets, dinocap, compounds, data, washes, qualifier, quant, database, temp, locking, headspace, famphur, matrix, target, makeup, identities, dinoseb, helium, microfluidic, matches, heptachlor, can, endrin, deconvolved, cyfluthrin
Podobná PDF
Excellent choices for environmental applications
2009|Agilent Technologies|Příručky
Solutions that meet your demands for: speed accuracy productivity Excellent choices for environmental applications Productivity Tools Applications > Return to Table of Contents > Search entire document Integrated Second Peristaltic Pump for Improved Sample Throughput and Reduced Matrix Effects Technical…
Klíčová slova
rtl, rtlpressure, pressuretime, timecolumn, columnaed, aedmethod, methodlocking, lockingagilent, agilentrtlock, rtlockretention, retentionicp, icpcan, caninlet, inletflow, flowelement
Replacing Multiple 50-Minute GC and GC-MS/SIM Analyses with One 15-Minute Full-Scan GC-MS Analysis for Nontargeted Pesticides Screening and >10x Productivity Gain
2007|Agilent Technologies|Aplikace
Replacing Multiple 50-Minute GC and GC-MS/SIM Analyses with One 15-Minute Full-Scan GC-MS Analysis for Nontargeted Pesticides Screening and >10x Productivity Gain Application Food Safety Author Introduction Chin-Kai Meng and Mike Szelewski Agilent Technologies 2850 Centerville Road Wilmington, DE 19808 To…
Klíčová slova
cfsan, cfsanµecd, µecddeconvolution, deconvolutionfda, fdasplitter, splitteramdis, amdisspectrum, spectrumtid, tidpeach, peachginseng, ginsengagilent, agilentfpd, fpdthree, threeflow, flowlibrary
Identifying Pesticides with Full Scan, SIM, μECD, and FPD from a Single Injection
2005|Agilent Technologies|Aplikace
Identifying Pesticides with Full Scan, SIM, µECD, and FPD from a Single Injection Application Food Safety, Environmental Authors Chin-Kai Meng and Bruce Quimby Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808-1610 USA Abstract In this application note, a gas…
Klíčová slova
fpd, fpdµecd, µecdsplitter, splitterscan, scansim, simepc, epcrestrictor, restrictormsd, msdway, waylibrary, librarysplit, splitmode, modetemp, tempfull, fullconstant
Screening for 926 Pesticides and Endocrine Disruptors by GC/MS with Deconvolution Reporting Software and a New Pesticide Library
2006|Agilent Technologies|Aplikace
Screening for 926 Pesticides and Endocrine Disruptors by GC/MS with Deconvolution Reporting Software and a New Pesticide Library Application Note Food and Environmental Authors USA endocrine disrupters in about two minutes per sample. Deconvolution helps identify pesticides that are buried…
Klíčová slova
methyl, methylester, esterdrs, drsphthalate, phthalatesulfone, sulfoneamdis, amdisoxon, oxonisomer, isomerethyl, ethylagilent, agilentdatabase, databasedeconvolution, deconvolutionpesticide, pesticidelibrary, librarycas