Analysis of Suspected Flavor andFragrance Allergens in Cosmetics Usingthe 7890A GC and Capillary ColumnBackflushApplicationFoodAuthorsFrank DavidResearch Institute for ChromatographyPres. Kennedypark 268500 KortrijkBelgiumMatthew S. KleeAgilent Technologies, Inc.2850 Centerville RoadWilmington, DE 19808-1610USAAbstractFlavor and fragrance allergens are determined in cosmetics using GC-MS. After simple...
Klíčová slova
allergens, allergensbackflush, backflushfragrance, fragrancebenzyl, benzylretained, retainedcolumn, columnabundance, abundancetime, timequickswap, quickswaprepeatability, repeatabilitysample, sampleflavor, flavorbenzoate, benzoatefrom, frompressure
A Column-Flow Independent Configuration for QuickSwap
2007|Agilent Technologies|Technické články
A Column-Flow Independent Configurationfor QuickSwapApplicationMatthew S. Klee and Bruce QuimbyAgilent Technologies, Inc.2850 Centerville RoadWilmington, DE 19808USAAs can be seen from Figure 1, if the column is disconnected from QuickSwap, a flow of inert gasfrom the Aux EPC will prevent air...
Klíčová slova
quickswap, quickswaprestrictor, restrictormsd, msdepc, epcpulse, pulseaux, auxflow, flowpressure, pressureconfiguration, configurationlarger, largervented, ventedsplit, splitchange, changefid, fidcolumn
The Use Of Automated Backflush on the 7890A/5975A GC-MS System
2008|Agilent Technologies|Technické články
The Use Of Automated Backflush on the7890A/5975A GC-MS SystemSetup Example Using BiomarkersApplicationHydrocarbon ProcessingAuthorsCourtney Milner and Russell KinghornBST International41 Greenaway StreetBulleen, VIC 3105AustraliaMatthew S. Klee2850 Centerville RoadAgilent Technologies, Inc.Wilmington, DE 19808USAAbstractThe use of column backflushing in capillary gas chromatography has been...
Klíčová slova
backflush, backflushabundance, abundancemsd, msdcolumn, columnbackflushing, backflushinginlet, inletrun, runpressure, pressureplugged, pluggedtime, timeboiling, boilingsplit, splitcapillary, capillaryrestrictor, restrictorconspired
Replacing Multiple 50-Minute GCand GC-MS/SIM Analyses with One15-Minute Full-Scan GC-MS Analysisfor Nontargeted Pesticides Screening and>10x Productivity GainApplicationFood SafetyAuthorIntroductionChin-Kai Meng and Mike SzelewskiAgilent Technologies2850 Centerville RoadWilmington, DE 19808To have a plentiful food supply, most fruits andvegetables are treated with pesticides (insecticides,...
Klíčová slova
cfsan, cfsanµecd, µecddeconvolution, deconvolutionfda, fdasplitter, splitteramdis, amdisspectrum, spectrumtid, tidginseng, ginsengpeach, peachagilent, agilentthree, threefpd, fpdflow, flowlibrary
 

Podobná PDF

Toggle
Analysis of Suspected Flavor andFragrance Allergens in Cosmetics Usingthe 7890A GC and Capillary ColumnBackflushApplicationFoodAuthorsFrank DavidResearch Institute for ChromatographyPres. Kennedypark 268500 KortrijkBelgiumMatthew S. KleeAgilent Technologies, Inc.2850 Centerville RoadWilmington, DE 19808-1610USAAbstractFlavor and fragrance allergens are determined in cosmetics using GC-MS. After simple...
Klíčová slova
allergens, allergensbackflush, backflushfragrance, fragrancebenzyl, benzylretained, retainedcolumn, columnabundance, abundancetime, timequickswap, quickswaprepeatability, repeatabilitysample, sampleflavor, flavorbenzoate, benzoatefrom, frompressure
A Column-Flow Independent Configuration for QuickSwap
2007|Agilent Technologies|Technické články
A Column-Flow Independent Configurationfor QuickSwapApplicationMatthew S. Klee and Bruce QuimbyAgilent Technologies, Inc.2850 Centerville RoadWilmington, DE 19808USAAs can be seen from Figure 1, if the column is disconnected from QuickSwap, a flow of inert gasfrom the Aux EPC will prevent air...
Klíčová slova
quickswap, quickswaprestrictor, restrictormsd, msdepc, epcpulse, pulseaux, auxflow, flowpressure, pressureconfiguration, configurationlarger, largervented, ventedsplit, splitchange, changefid, fidcolumn
The Use Of Automated Backflush on the 7890A/5975A GC-MS System
2008|Agilent Technologies|Technické články
The Use Of Automated Backflush on the7890A/5975A GC-MS SystemSetup Example Using BiomarkersApplicationHydrocarbon ProcessingAuthorsCourtney Milner and Russell KinghornBST International41 Greenaway StreetBulleen, VIC 3105AustraliaMatthew S. Klee2850 Centerville RoadAgilent Technologies, Inc.Wilmington, DE 19808USAAbstractThe use of column backflushing in capillary gas chromatography has been...
Klíčová slova
backflush, backflushabundance, abundancemsd, msdcolumn, columnbackflushing, backflushinginlet, inletrun, runpressure, pressureplugged, pluggedtime, timeboiling, boilingsplit, splitcapillary, capillaryrestrictor, restrictorconspired
Replacing Multiple 50-Minute GCand GC-MS/SIM Analyses with One15-Minute Full-Scan GC-MS Analysisfor Nontargeted Pesticides Screening and>10x Productivity GainApplicationFood SafetyAuthorIntroductionChin-Kai Meng and Mike SzelewskiAgilent Technologies2850 Centerville RoadWilmington, DE 19808To have a plentiful food supply, most fruits andvegetables are treated with pesticides (insecticides,...
Klíčová slova
cfsan, cfsanµecd, µecddeconvolution, deconvolutionfda, fdasplitter, splitteramdis, amdisspectrum, spectrumtid, tidginseng, ginsengpeach, peachagilent, agilentthree, threefpd, fpdflow, flowlibrary
 

Mohlo by Vás zajímat

Utilising unique TOF-MS technology and hydrogen carrier gas for fast GC-MS to produce robust, high quality, library comparable mass spectral data

Postery
| 2022 | LECO
Instrumentace
GC/MSD, GC/TOF
Výrobce
LECO
Zaměření
---

Determination of BTEX and volatile organic compounds (VOCs) in drinking water by GC-MS/MS coupled to static headspace and solid-phase microextraction sampling

Aplikace
| 2022 | Thermo Fischer Scientific
Instrumentace
GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ
Výrobce
Thermo Fischer Scientific
Zaměření
Životní prostředí

Analysis of Trace Perfluorinated and Polyfluorinated Organic Vapors in Air

Aplikace
| 2022 | Agilent Technologies
Instrumentace
GC/MSD, Termální desorpce, GC/SQ
Výrobce
Agilent Technologies, Markes
Zaměření
Životní prostředí

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GC/MS System

Aplikace
| 2022 | Shimadzu
Instrumentace
GC/MSD, HeadSpace, GC/SQ
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

Analysis of Heavy Fuel Oil Using Multi-Mode Ionization

Aplikace
| 2022 | LECO
Instrumentace
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Výrobce
LECO
Zaměření
Průmysl a chemie
 

Mohlo by Vás zajímat

Utilising unique TOF-MS technology and hydrogen carrier gas for fast GC-MS to produce robust, high quality, library comparable mass spectral data

Postery
| 2022 | LECO
Instrumentace
GC/MSD, GC/TOF
Výrobce
LECO
Zaměření
---

Determination of BTEX and volatile organic compounds (VOCs) in drinking water by GC-MS/MS coupled to static headspace and solid-phase microextraction sampling

Aplikace
| 2022 | Thermo Fischer Scientific
Instrumentace
GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ
Výrobce
Thermo Fischer Scientific
Zaměření
Životní prostředí

Analysis of Trace Perfluorinated and Polyfluorinated Organic Vapors in Air

Aplikace
| 2022 | Agilent Technologies
Instrumentace
GC/MSD, Termální desorpce, GC/SQ
Výrobce
Agilent Technologies, Markes
Zaměření
Životní prostředí

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GC/MS System

Aplikace
| 2022 | Shimadzu
Instrumentace
GC/MSD, HeadSpace, GC/SQ
Výrobce
Shimadzu
Zaměření
Průmysl a chemie

Analysis of Heavy Fuel Oil Using Multi-Mode Ionization

Aplikace
| 2022 | LECO
Instrumentace
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Výrobce
LECO
Zaměření
Průmysl a chemie
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití

LabRulez s.r.o. Všechna práva vyhrazena.