A Total Solution for the Analysis of Melamine and Cyanuric Acid in Pet Food by GC/MS and Aqueous Normal-Phase LC/MS/MS
Aplikace | 2007 | Agilent TechnologiesInstrumentace
GC/MSD, GC/SQ, LC/MS, LC/MS/MS, LC/QQQ
ZaměřeníPotraviny a zemědělství
VýrobceAgilent Technologies
Klíčová slovacyanuric, melamine, acid, sim, dwell, pet, food, ions, scan, abundance, mode, phase, mass, trimethylsilyl, normal, both, method, fluids, preparation, yanyan, used, animal, readily, monitoring, compounds, chosen, fang, derivatization, luan, extraction, dry, parameters, zweigenbaum, details, jerry, done, time, conditions, wei, confirmation, selective, retention, polar, liquid, aqueous, nitrogen, noise, disturbance, evaporating, sample
Podobná PDF
GC/MS Analysis of Melamine and Cyanuric Acid Below 1 μg/g in Infant Formula
2018|Shimadzu|Aplikace
GC/MS Analysis of Melamine and Cyanuric Acid Below 1 μg/g in Infant Formula Abstract The establishment of a 1 μg/g safety threshold for melamine in infant foods has led to a need for sensitive methods. Here, we established GC/MS conditions…
Klíčová slova
melamine, melaminecyanuric, cyanuricammelide, ammelideammeline, ammelineacid, acidbenzoguanamine, benzoguanaminenylon, nyloninfant, infantmin, minderivatization, derivatizationratios, ratiosdeaths, deathsmatrix, matrixillnesses, illnessesformula
Trace-Level Analysis of Melamine in Milk Products on Agilent 7890A/5975C GC/MSD Using a New Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges
2008|Agilent Technologies|Aplikace
Trace-Level Analysis of Melamine in Milk Products on Agilent 7890A/5975C GC/MSD Using a New Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application Note Gas Chromatography/Mass Spectrometry/Food Safety Authors Abstract Min Cai and Yun Zou A GC/MS method…
Klíčová slova
melamine, melaminemilk, milktms, tmssampliq, sampliqabundance, abundancescx, scxtri, trirecovery, recoverymode, modelevel, levellyzed, lyzedreagents, reagentsresin, resintrace, tracescan
Simultaneous Extraction of Melamine and Cyanuric Acid from Food Products Using Strata® Melamine SPE and Ultra-fast LC/MS/MS Analysis Using Kinetex™ HILIC, Rapid LC/MS/MS Analysis on Luna® HILIC, or Rapid GC/MS Analysis on Zebron™ ZB-XLB HT
2009|Agilent Technologies|Aplikace
TN-0021 APPLICATIONS Simultaneous Extraction of Melamine and Cyanuric Acid from Food Products Using Strata® Melamine SPE and Ultra-fast LC/MS/MS Analysis Using Kinetex™ HILIC, Rapid LC/MS/MS Analysis on Luna® HILIC, or Rapid GC/MS Analysis on Zebron™ ZB-XLB HT Shahana Wahab Huq,…
Klíčová slova
melamine, melaminecyanuric, cyanuricacid, acidbaby, babyzebron, zebronxlb, xlbluna, lunainferno, infernokinetex, kinetexhilic, hilicstrata, strataformula, formulaextraction, extractioncomplete, completeextracts
Rapid Screening of Melamine and Cyanuric Acid in Milk Products Using Agilent J&W HP-5ms GC Column and Agilent 7890A/5975C GC/MSD with Column Backflushing
2008|Agilent Technologies|Aplikace
Rapid Screening of Melamine and Cyanuric Acid in Milk Products Using Agilent J&W HP-5ms GC Column and Agilent 7890A/5975C GC/MSD with Column Backflushing Application Note Food Safety Authors Abstract Min Cai, Chongtian Yu, Yun Zou, A rapid screening method for…
Klíčová slova
cyanuric, cyanuricmelamine, melaminemilk, milktms, tmstri, triacid, acidrestrictor, restrictorbackflush, backflushscreening, screeningoutlet, outletcapped, cappedsim, simmode, modepressure, pressurereagents